aiwiki.page
English
Science / Chemistry / vapor-pressure

Vapor Pressure

Vapor pressure is the equilibrium pressure of a vapor above its liquid or solid phase at a specified temperature.

48 keywords11 linked from6 not yet writtenWritten by AI
PressureTemperatureWaterEvaporationCondensationThermodynamicsThermodynamic Eq…Partial PressureVapor Pres…

Vapor pressure is the pressure exerted by a vapor in equilibrium with its liquid or solid phase at a specified temperature. For a pure substance above a flat surface, it is principally a function of temperature: warmer material generally has a higher vapor pressure. The term usually denotes an equilibrium property, not the actual pressure of vapor in an arbitrary environment. A dry room, for example, can contain much less water vapor than would be present at equilibrium with liquid water.

Vapor pressure connects molecular interactions with observable processes such as evaporation, boiling, drying, and condensation. It determines the conditions under which liquids can boil, helps establish the composition of vapor above mixtures, and governs exchanges of water between surfaces and the atmosphere. Its measurement and prediction are therefore central to thermodynamics, chemical engineering, meteorology, and environmental science.

Definition, equilibrium, and units

Consider a sealed, evacuated vessel containing a pure liquid at a fixed temperature. Some liquid enters the initially empty space above it. As vapor accumulates, molecules also return to the liquid. Provided that enough liquid remains and the system reaches thermodynamic equilibrium, the vapor pressure approaches a reproducible value. Adding more liquid does not change that value unless the addition changes temperature, composition, or interfacial conditions. Enlarging the vapor space likewise leaves the equilibrium pressure unchanged if sufficient liquid remains to supply the additional vapor.

This independence from quantity has an important qualification. If all the liquid evaporates before saturation is reached, the resulting gas pressure depends on the amount of substance and the vessel volume. It is then not necessarily the saturation vapor pressure. Likewise, the vapor pressure measured above a contaminated liquid may differ from the value for the pure substance. Specifying temperature, chemical composition, and the condensed phase is therefore essential when reporting vapor-pressure data.

In a mixture of gases, the vapor contributes a partial pressure rather than necessarily accounting for the total pressure. Water at 25 °C has a saturation vapor pressure of approximately 3.17 kPa. Above liquid water in a vessel also containing air, the total pressure includes the contributions of nitrogen, oxygen, and other gases. At moderate pressures, the equilibrium partial pressure of water is close to 3.17 kPa, not the total gas pressure. Precise treatments account for gas nonideality, dissolved gases, and the effect of total pressure on the liquid’s chemical potential.

The SI unit is the pascal, equivalent to one newton per square metre. Kilopascals and megapascals are convenient for many engineering applications; hectopascals are common in meteorology. Older tables frequently use millimetres of mercury, torr, atmospheres, or bars. One standard atmosphere is exactly 101,325 Pa, and one bar is exactly 100,000 Pa. A numerical vapor pressure without its temperature and unit is incomplete.

The term applies to solids as well as liquids. Ice, iodine, and many organic crystals establish a vapor in equilibrium with their solid surfaces through sublimation. A substance need not be visibly boiling or rapidly evaporating to have a vapor pressure. Conversely, a high observed evaporation rate does not by itself establish a high equilibrium vapor pressure, because airflow, exposed area, and heat supply also control the rate.

Molecular origins and the distinction from evaporation rate

At a liquid surface, individual molecules continually move between the condensed and gaseous phases. Their motions and interactions are distributed over many microscopic states. Escape into the vapor requires a molecular configuration and sufficient energy to overcome the attractive environment of the liquid; return to the liquid transfers molecules and energy in the opposite direction. Equilibrium is dynamic: the opposing molecular fluxes are equal, even though exchange continues.

The vapor pressure reflects the balance between energetic stabilization in the condensed phase and the greater number of accessible configurations in the vapor. Strong intermolecular attractions generally reduce vapor pressure when other factors are comparable. Water’s extensive hydrogen bonding, for example, helps explain why it is less volatile than many small molecules of similar molecular mass. Molecular shape, polarizability, and the organization of the liquid also matter. Consequently, neither molecular mass nor a single bond-energy measure reliably predicts vapor pressure across chemically diverse substances.

Statistical mechanics expresses this balance through the populations and free energies of molecular states. The often-used picture that only the “fastest molecules” evaporate captures part of the kinetic behavior but is incomplete. Molecules interact with neighbors, exchange energy, and cross a structured interface. Equilibrium vapor pressure depends on the free-energy difference between phases, not simply on the fraction of isolated molecules exceeding one universal kinetic-energy threshold.

Evaporation rate is a nonequilibrium quantity. For a simplified interface bordering a dilute vapor, a kinetic expression for the net outward molecular number flux is

J=αpsat−pv2πmkBT,J=\alpha\frac{p_{\mathrm{sat}}-p_v} {\sqrt{2\pi m k_{\mathrm B}T}},

where psatp_{\mathrm{sat}} is the saturation vapor pressure, pvp_v is the adjacent vapor pressure, mm is molecular mass, kBk_{\mathrm B} is the Boltzmann constant, and α\alpha represents an interfacial accommodation factor. This form assumes a common interfacial temperature and a simplified description of molecular exchange. More general expressions distinguish evaporation and condensation coefficients and the temperatures of the two phases.

In ordinary air, transport away from the interface often limits evaporation more strongly than the interfacial exchange itself. Diffusion through a humid boundary layer, air movement, and the supply of heat can all be decisive. Evaporation also cools a surface because outgoing material carries energy associated with vaporization. A shallow dish and a narrow-necked bottle can therefore lose the same liquid at very different rates despite having the same equilibrium vapor pressure at the same temperature.

Thermodynamic basis and temperature dependence

The fundamental equilibrium condition is equality of chemical potential between phases. For a pure liquid and its vapor,

μl(T,psat)=μv(T,psat).\mu_l(T,p_{\mathrm{sat}})=\mu_v(T,p_{\mathrm{sat}}).

Chemical potential is the change in Gibbs free energy associated with adding matter under specified conditions. If the chemical potential is higher in one phase than the other, transfer toward the lower value reduces the system’s free energy. At coexistence, neither direction produces a net thermodynamic advantage.

The slope of the liquid–vapor coexistence curve is given by the Clapeyron equation:

dpsatdT=ΔhvapT(vv−vl),\frac{dp_{\mathrm{sat}}}{dT} =\frac{\Delta h_{\mathrm{vap}}} {T(v_v-v_l)},

where Δhvap\Delta h_{\mathrm{vap}} is the molar enthalpy of vaporization and vvv_v and vlv_l are the molar volumes of vapor and liquid. For ordinary liquid–vapor coexistence, both the enthalpy and volume changes are positive, so vapor pressure rises with temperature. The equation follows from the equality of chemical potentials and the thermodynamic relation dμ=−s dT+v dpd\mu=-s\,dT+v\,dp.

If the vapor behaves as an ideal gas and its molar volume greatly exceeds that of the liquid, the result becomes the Clausius–Clapeyron equation:

dln⁡psatdT=ΔhvapRT2,\frac{d\ln p_{\mathrm{sat}}}{dT} =\frac{\Delta h_{\mathrm{vap}}}{RT^2},

where RR is the gas constant. Treating the enthalpy of vaporization as approximately constant over a limited interval gives

ln⁡(p2p1)=−ΔhvapR(1T2−1T1).\ln\left(\frac{p_2}{p_1}\right) =-\frac{\Delta h_{\mathrm{vap}}}{R} \left(\frac{1}{T_2}-\frac{1}{T_1}\right).

Temperatures in these equations must be absolute, normally expressed in kelvins.

This relation explains why vapor pressure often changes rapidly with warming. Around 20 °C, the saturation vapor pressure of water increases by roughly 6% per kelvin. The percentage is not a universal constant: it depends on temperature and the substance’s enthalpy of vaporization. Water’s saturation pressure is approximately 0.611 kPa at 0 °C, 2.34 kPa at 20 °C, 7.38 kPa at 40 °C, and 101.4 kPa at 100 °C.

The development of this treatment joined nineteenth-century studies of heat engines and phase change. Benoît Paul Émile Clapeyron formulated the coexistence relation in 1834; Rudolf Clausius subsequently developed the thermodynamic framework underlying its widely used approximate form. Modern calculations incorporate temperature-dependent vaporization enthalpy and realistic equations of state. Close to the critical point, the assumptions of an ideal vapor and negligible liquid volume fail, and extrapolating a simple integrated expression can produce substantial errors.

Boiling, sublimation, and phase boundaries

A liquid’s boiling point is the temperature at which its vapor pressure matches the pressure imposed on the liquid, under the usual macroscopic equilibrium description. At that condition, vapor bubbles can exist within the liquid rather than only above its surface. The normal boiling point refers specifically to an external pressure of one standard atmosphere. A boiling point specified at 100 kPa is slightly different, a distinction that matters in precise property tables.

Boiling therefore does not require one fixed temperature. Water boils at approximately 100 °C under one atmosphere, but at about 60 °C when the pressure is near 19.9 kPa. At higher external pressures, the boiling temperature rises. Within a liquid, hydrostatic pressure increases with depth, while the curved surface of a small vapor bubble creates an additional pressure difference. Bubble formation also involves nucleation barriers. A sufficiently clean liquid can consequently become superheated above its equilibrium boiling temperature before vigorous boiling begins.

On a phase diagram, the liquid–vapor coexistence curve meets the solid–vapor and solid–liquid curves at the triple point. For water, the triple-point temperature is 273.16 K and the pressure is approximately 611.657 Pa. Below the triple-point pressure, stable liquid water cannot exist in bulk equilibrium: heating ice produces sublimation rather than an intervening stable liquid phase. This is the thermodynamic basis of freeze-drying, in which frozen material loses water under reduced pressure.

The liquid–vapor curve terminates at the critical point, where the distinction between liquid and vapor disappears. Water’s critical temperature is approximately 647.096 K and its critical pressure is 22.064 MPa. Above the critical temperature, compression alone cannot produce a conventional liquid–vapor phase transition. A “saturation vapor pressure” for liquid–vapor coexistence is therefore not defined beyond that endpoint, although a supercritical fluid still has an ordinary mechanical pressure.

For solids, the relevant equilibrium is between vapor and a particular crystalline phase. Different crystal forms can have different chemical potentials and therefore different vapor pressures. Below 0 °C, supercooled liquid water has a higher equilibrium vapor pressure than ice at the same temperature. At −10 °C, representative values are approximately 0.286 kPa over supercooled water and 0.260 kPa over ice. Thus air can be saturated with respect to liquid droplets while supersaturated with respect to ice, allowing ice crystals to grow at the expense of droplets. Such distinctions show why the identity and stability of the condensed phase must accompany a vapor-pressure value.

Solutions, partial pressures, and nonideal mixtures

Above a liquid mixture, each volatile component contributes to the vapor, and the equilibrium composition generally differs from that of the liquid. For an ideal liquid solution in equilibrium with an ideal-gas vapor, Raoult’s law states

pi=xipi∗(T),p_i=x_i p_i^{*}(T),

where pip_i is the partial pressure of component ii, xix_i its liquid-phase mole fraction, and pi∗p_i^{*} the vapor pressure of the pure component. The total pressure is P=∑ipiP=\sum_i p_i, and the vapor-phase mole fraction is yi=pi/Py_i=p_i/P. These relations connect pure-substance vapor pressures directly to vapor–liquid equilibrium.

For a binary mixture, the more volatile component is generally enriched in the vapor. In the ideal approximation, the relative volatility is

α12=y1/x1y2/x2=p1∗p2∗.\alpha_{12} =\frac{y_1/x_1}{y_2/x_2} =\frac{p_1^{*}}{p_2^{*}}.

A large relative volatility makes separation by distillation easier; a value near unity makes it difficult. The relationship is temperature dependent and, in real mixtures, often composition dependent. It is therefore insufficient to compare only the normal boiling points of the pure substances when designing a separation.

Real solutions are commonly described using an activity coefficient:

pi≈xiγipi∗.p_i\approx x_i\gamma_i p_i^{*}.

Here γi\gamma_i measures departure from the ideal-solution reference state. Mixtures in which unlike molecular interactions differ substantially from like interactions can show strong positive or negative deviations. Some form an azeotrope, at which the equilibrium vapor and liquid have the same composition. Ethanol and water form a minimum-boiling azeotrope at atmospheric pressure, near 95.6% ethanol by mass. Ordinary equilibrium distillation cannot cross that composition at fixed pressure.

A nonvolatile solute lowers the solvent’s vapor pressure because it reduces the solvent’s chemical potential. In the ideal limit, the solvent pressure decreases in proportion to its mole fraction; more generally it is related to thermodynamic activity. This behavior underlies vapor-pressure lowering and its connection with osmosis, boiling-point elevation, and freezing-point depression. Electrolyte solutions require particular care because ion interactions and dissociation make simple particle-counting approximations inadequate outside dilute conditions.

At low solute concentration, a volatile dissolved species may instead follow Henry’s law, commonly written pi=Hixip_i=H_i x_i for one convention. Henry constants have several definitions and unit systems, so their convention must be stated. At higher gas pressures, partial pressure is replaced in rigorous equilibrium expressions by fugacity, which accounts for gas nonideality. These distinctions are important for gases dissolved in water, pressurized chemical processes, and environmental partitioning.

Curved surfaces, small particles, and porous materials

The usual tabulated vapor pressure refers to equilibrium with a macroscopically flat surface. A curved interface changes the pressure and chemical potential of the condensed phase. For a spherical liquid droplet, the pressure inside exceeds that outside by approximately 2γ/r2\gamma/r, where γ\gamma is surface tension and rr is the droplet radius. This additional mechanical pressure raises the liquid’s chemical potential and therefore raises the vapor pressure needed to maintain equilibrium.

For a pure spherical droplet, the Kelvin equation is commonly written

ln⁡(prp∞)=2γVmrRT,\ln\left(\frac{p_r}{p_\infty}\right) =\frac{2\gamma V_m}{rRT},

where prp_r is the equilibrium vapor pressure above the droplet, p∞p_\infty is the flat-surface value, and VmV_m is the liquid molar volume. The expression assumes a nearly incompressible liquid, an approximately ideal vapor, and a continuum interface characterized by a macroscopic surface tension. The curvature effect becomes appreciable for very small droplets and is negligible for many everyday containers.

For water near 20 °C, the quantity 2γVm/(RT)2\gamma V_m/(RT) is about 1.1 nanometres. A droplet of radius 0.1 micrometre therefore requires a vapor pressure roughly 1% above the flat-surface value to remain in equilibrium, while a droplet ten times larger requires a much smaller excess. Applying the continuum equation to molecular-sized clusters is problematic because surface structure and the meaning of surface tension cease to be adequately represented by their bulk values.

Curvature reverses its effect for a concave liquid meniscus. In a wetting pore, condensation can occur below the saturation pressure over a flat surface. This capillary condensation helps explain moisture retention in soils, building materials, and fine porous solids. The equilibrium depends on pore geometry, contact angle, surface chemistry, and temperature. Adsorption onto pore walls may precede capillary filling, and interconnected pore networks can produce hysteresis between wetting and drying.

Curvature also links vapor pressure to particle growth and cloud formation. Small droplets have a greater tendency to evaporate than larger ones under otherwise identical conditions. Dissolved salts counteract this by lowering water activity. In atmospheric aerosol particles, competition between the curvature effect and solute-induced vapor-pressure lowering produces the equilibrium relationships described by Köhler theory. These relationships help determine the supersaturation required for a particle to activate into a cloud droplet. In dispersions, differences in chemical potential associated with particle size can also drive Ostwald ripening, with larger particles growing as smaller ones lose material.

Measurement, empirical equations, and data quality

Vapor-pressure measurements span an enormous range, from pressures well below one pascal for low-volatility solids to megapascals near the critical points of common fluids. No single instrument is optimal across this range. The central experimental requirements are an accurately known sample temperature, a well-characterized substance, control of unwanted gases, and sufficient time for equilibrium. Because vapor pressure changes steeply with temperature, even a small temperature error can dominate the pressure uncertainty.

In a static method, a liquid or solid is allowed to equilibrate with its vapor in a closed apparatus, and the pressure is measured directly. The sample and vapor space must be sufficiently isothermal to avoid condensation at an unintended colder location. Residual air or other noncondensable gases add to the measured pressure, while volatile impurities may contribute disproportionately. Degassing and careful sample preparation are therefore integral to high-quality measurements, rather than merely preliminary housekeeping.

Dynamic methods determine the temperature at which a liquid boils under a known pressure, often using an ebulliometer. Transpiration methods pass a carrier gas over or through a sample and infer vapor pressure from the quantity transported, provided the exiting gas is saturated and entrained droplets or particles are excluded. At very low pressures, Knudsen effusion relates the rate at which molecules escape through a small aperture to the equilibrium vapor pressure. Its validity requires an appropriate molecular-flow regime and an aperture that does not excessively disturb equilibrium.

Measured data are often represented by the Antoine equation, introduced by Louis Charles Antoine in 1888:

log⁡10p=A−BT+C.\log_{10}p=A-\frac{B}{T+C}.

The coefficients depend on the substance, temperature interval, and chosen pressure and temperature units. Celsius temperatures are used in many published coefficient sets, unlike the absolute temperatures required in the Clausius–Clapeyron equation. Mixing coefficient conventions can cause major errors. Antoine correlations are useful within their fitted ranges but are not generally suitable for unrestricted extrapolation, especially toward the critical point.

More elaborate correlations and multiparameter equations of state represent wider ranges and enforce additional thermodynamic constraints. For water and steam, formulations developed under the International Association for the Properties of Water and Steam are widely used. Evaluating a dataset involves more than comparing fitted residuals: calibration, sample purity, temperature gradients, equilibrium tests, and measurement uncertainty all matter. For substances that decompose, change crystal form, or adsorb strongly on apparatus surfaces, the measured signal may not represent equilibrium vapor pressure of the intended material.

Atmospheric humidity and the water cycle

In atmospheric science, actual water-vapor pressure is usually denoted ee, while saturation vapor pressure is denoted es(T)e_s(T). Relative humidity is approximately

RH=100 ees(T).\mathrm{RH}=100\,\frac{e}{e_s(T)}.

The reference surface must be specified when ice is relevant, since saturation over ice differs from saturation over supercooled liquid water. More precise definitions account for the fact that water vapor is mixed with air rather than existing as a pure vapor. For many everyday meteorological calculations, the pressure-ratio approximation is adequate.

The dew point is the temperature to which air must be cooled, at approximately constant pressure and unchanged water-vapor content, to reach saturation with respect to liquid water. A corresponding frost point refers to equilibrium with ice. Because saturation vapor pressure decreases on cooling, air can become saturated without acquiring additional moisture. Conversely, warming air at unchanged vapor content lowers its relative humidity. Saying that warm air “holds more water” is a convenient shorthand, but the underlying constraint is phase equilibrium, not a fixed storage capacity of air molecules.

The vapor-pressure deficit is the difference es(T)−ee_s(T)-e, with the relevant temperature depending on the application. For a leaf or water surface, the physically important driving difference is between saturation at the surface temperature, adjusted when necessary for water activity, and the surrounding vapor pressure. This deficit influences evapotranspiration, together with radiation, wind, transport resistance, and water availability. Two environments with the same relative humidity can have different vapor-pressure deficits because their temperatures differ.

The contrast between saturation over ice and over liquid water plays a major role in mixed-phase clouds. When ice crystals and supercooled droplets coexist, conditions can favor vapor deposition onto ice while liquid droplets evaporate. This process contributes to precipitation formation. Actual cloud evolution also depends on aerosol particles, collisions, turbulence, and the supply of water vapor; equilibrium vapor-pressure differences alone do not determine the resulting precipitation.

Temperature-dependent saturation vapor pressure also connects the water cycle with climate change. Near typical lower-atmospheric temperatures, its fractional increase is often approximated as about 7% per kelvin. This is a local thermodynamic scaling, not a universal prediction for rainfall, atmospheric water content, or evaporation. Water vapor is a greenhouse gas, and its response to warming contributes to climate feedbacks, but regional humidity and precipitation depend additionally on circulation, moisture transport, surface conditions, and energy constraints.

Industrial processes and environmental behavior

Vapor-pressure data are basic inputs to separation and thermal-processing equipment. In distillation, pure-component vapor pressures and mixture activity models determine equilibrium compositions and operating pressures. Vacuum distillation lowers boiling temperatures and is used where high temperatures would promote decomposition or unwanted reactions. In refrigeration, an operating fluid absorbs heat while evaporating at low pressure and releases heat while condensing at higher pressure. Its vapor-pressure curve helps determine the temperatures and pressures available within the cycle.

Drying processes depend on both equilibrium and transport. The vapor pressure of water or a solvent at the material surface establishes a thermodynamic boundary condition, while heat transfer and diffusion govern removal rates. As a material dries, its remaining liquid may become concentrated, confined in small pores, or strongly associated with the solid. Its equilibrium vapor pressure can therefore fall below the pure-liquid value. Freeze-drying operates in a different phase region: ice sublimes under reduced pressure, with heat supplied to sustain sublimation and a colder surface used to collect the vapor.

In pumps and hydraulic machinery, vapor pressure defines an important limit on local liquid pressure. If pressure falls sufficiently low, vapor cavities can form; their subsequent collapse in higher-pressure regions is called cavitation. Cavitation can cause noise, vibration, loss of performance, and material damage. Pump calculations compare the available suction conditions with those needed to avoid unacceptable cavitation. Temperature matters strongly because warmer liquids commonly have higher vapor pressures and thus a smaller margin before vapor formation.

In environmental chemistry, vapor pressure helps characterize a substance’s tendency to enter the gas phase from a pure or concentrated source. It does not, by itself, determine environmental mobility. Transfer from dilute water solutions also depends on Henry’s law behavior, while release from soils and sediments depends on adsorption, organic matter, water content, and diffusion. A compound with a measurable vapor pressure may nevertheless be retained strongly by soil or other materials. Temperature changes can alter both its vapor pressure and its distribution among environmental compartments.

Petroleum products illustrate why a reported “vapor pressure” may be an operational test result rather than a simple pure-substance property. Gasoline contains many volatile components, and its measured pressure depends on temperature, composition, vapor-to-liquid ratio, and the prescribed test procedure. Reid vapor pressure, for example, is determined by a standardized method at 37.8 °C and is not interchangeable with every definition of true vapor pressure. Similar care is needed for formulations that lose their most volatile ingredients during handling: the composition changes, so subsequent equilibrium pressures describe a different mixture.