Acid–base titration is a method of analytical chemistry in which the amount of an acid or base is determined by measuring the quantity of a reagent needed to react with it in a known proportion. The reagent, called the titrant, usually has an accurately established concentration and is added gradually to the sample. The method relies on an acid–base reaction and a detectable change near the point of stoichiometric completion. It is used to determine concentrations, assess purity, measure total acidity or alkalinity, and investigate acid–base equilibria.
Chemical basis
In aqueous solutions, acid–base titrations commonly involve proton transfer. For a strong acid reacting with a strong base, the net ionic reaction is
A weak acid, represented by , reacts with hydroxide according to
Although the weak acid is only partly dissociated before titration, removal of its acidic protons by hydroxide shifts the chemical equilibrium toward further dissociation. Consequently, weak acids can often be titrated quantitatively with strong bases.
A useful titration reaction must have known stoichiometry, proceed sufficiently rapidly, and be sufficiently complete under the measurement conditions. Side reactions and competing proton-transfer reactions can complicate the interpretation.
The equivalence point is the stage at which the amount of titrant added is stoichiometrically equivalent to the amount of analyte being measured. It is not necessarily the point at which the solution has a pH of 7.
The endpoint is the experimentally observed signal used to stop the titration or identify its completion, such as an indicator color change. The difference between the endpoint and the equivalence point produces an endpoint error. Distinguishing these two points is essential to accurate titration.
Apparatus and measurement
In conventional volumetric titration, the titrant is delivered from a burette into a flask containing a measured sample portion. A volumetric pipette commonly supplies the sample, and mixing prevents locally high concentrations of titrant from persisting. The delivered volume is the difference between the final and initial burette readings.
A typical determination includes:
- Establishing the titrant concentration by standardization.
- Measuring a representative sample portion.
- Adding titrant while mixing, with smaller additions near the endpoint.
- Detecting the endpoint by an indicator or an instrumental signal.
- Calculating the analyte amount from the titrant consumption and reaction stoichiometry.
Replicate measurements help assess repeatability. A reagent blank may be needed when the solvent, indicator, or other reagents consume a measurable amount of titrant.
Automatic titrators combine controlled reagent delivery, stirring, signal measurement, and data processing. They can locate endpoints from an entire titration curve rather than from a single visual observation.
Standard solutions and standardization
The concentration of a titrant must be known accurately. Preparing a solution by weighing a reagent and diluting it to a specified volume is not always sufficient: the reagent may contain impurities, absorb moisture, react with air, or change composition during storage.
A primary standard is a substance of sufficiently well-characterized purity and stability to establish a solution concentration accurately. Potassium hydrogen phthalate is widely used to standardize sodium hydroxide solutions. Suitable sodium carbonate preparations can be used to standardize strong-acid solutions.
Sodium hydroxide requires particular attention because it absorbs moisture and reacts with atmospheric carbon dioxide, forming carbonate. These changes can alter its effective concentration and endpoint behavior. Standardization determines the titrant concentration under specified conditions rather than relying solely on its nominal preparation.
Volumetric glassware, dispensing systems, and pH instruments also require appropriate calibration. Their calibration does not replace chemical standardization: instrument performance and reagent concentration are separate components of the measurement.
Titration curves
A titration curve plots pH against the volume of titrant added. Its shape depends on acid and base strengths, concentrations, the number of titratable protons, and the solvent. The steepness near equivalence determines how easily an endpoint can be identified.
Strong acid–strong base
For a strong acid titrated with a strong base, the pH before equivalence is governed mainly by excess acid; after equivalence, it is governed mainly by excess base. At moderate concentrations, a small addition near equivalence produces a large pH change.
At equivalence, an idealized solution containing a salt whose ions do not appreciably react with water is neutral:
Here, is the ionic product of water and . Neutral pH is approximately 7.00 at , but varies with temperature.
Weak acid–strong base
When a weak acid is titrated with a strong base, the mixture contains both the acid and its conjugate base before equivalence. This creates a buffer solution.
In the buffer region, the Henderson–Hasselbalch equation is commonly written approximately as
where is the acid dissociation constant. The concentration-based expression assumes that activity effects are sufficiently small or otherwise accounted for.
At half-equivalence, the analytical amounts of acid and conjugate base are equal, so
At equivalence, the conjugate base reacts with water through hydrolysis, making the solution alkaline. Thus, the equivalence-point pH is generally above neutral.
Weak base–strong acid
Titration of a weak base such as ammonia with a strong acid produces an analogous curve. Before equivalence, the weak base and its conjugate acid form a buffer. At equivalence, the conjugate acid makes the solution acidic, so the equivalence-point pH is generally below neutral.
Weak acid–weak base titrations often show a smaller pH change near equivalence. This can make visual endpoint detection unreliable, although suitability depends on the particular equilibrium constants, concentrations, and detection method.
Polyprotic acids and mixtures
Polyprotic acids can donate more than one proton per molecule and may show several equivalence points. Distinct steps are most readily resolved when successive dissociation constants differ substantially and the concentrations permit sufficiently pronounced pH changes.
Some mixtures of acids or bases can also be analyzed by resolving separate titration steps. When reactions overlap too strongly, the titration may measure only a combined acidity or basicity rather than the amount of each component independently.
Endpoint detection
Color indicators
An acid–base indicator is usually a weak acid or base whose conjugate forms have different colors. Its visible transition occurs over a pH interval rather than at one exact pH.
A suitable indicator changes color within the steep region of the titration curve, close enough to equivalence that the resulting volume error is acceptable. Phenolphthalein is commonly used for weak-acid–strong-base titrations, whereas methyl orange is useful for certain titrations with acidic endpoints. Indicator selection depends on the actual curve, not simply on whether the sample is labeled an acid or a base.
Colored or turbid samples can obscure an indicator transition. Adding excessive indicator can itself affect the acid–base balance, especially in dilute samples.
Potentiometric and other instrumental methods
Potentiometric titration follows the response of a pH-sensitive electrode, commonly a glass electrode. The equivalence region may be identified from an inflection in the pH curve or from its derivatives. More elaborate data treatments can estimate equivalence volumes from several measurements.
Instrumental detection is useful when samples are colored, when several endpoints may occur, or when a recorded curve is needed. It remains subject to electrode calibration, response time, mixing, and the suitability of the endpoint calculation.
Other methods monitor electrical conductivity, optical absorbance, or heat released during the reaction. Their signals reflect different properties of the reacting solution and need not have the same curve shape as a pH titration.
Quantitative calculations
For a reaction represented by
where is the analyte and the titrant, equivalence requires
Using molar concentration and solution volume ,
provided the sample preparation and any blank correction are included appropriately.
For example, if a sample of a monoprotic acid consumes of sodium hydroxide at equivalence, then
The simple equality applies only to a one-to-one reaction. For a polyprotic acid, the calculation must specify which endpoint is measured and how many protons per molecule have reacted.
Titration curves can also provide information about equilibrium constants. Rigorous interpretation may require thermodynamic activities, mass balances, charge balance, and corrections for changing volume.
Variants and applications
Direct titration adds titrant directly to the analyte until the selected endpoint is reached.
Back titration adds a known excess of reagent to the sample and then measures the unreacted excess with a second titrant. The analyte amount follows by subtraction. This approach is useful when direct reaction or dissolution is slow, or when a direct endpoint is difficult to observe.
Nonaqueous titration uses a solvent other than water, or a mixed solvent, to improve solubility or make otherwise weak acid–base behavior more analytically distinguishable. Acid and base strengths, indicator transitions, and electrode responses depend on the solvent, so aqueous assumptions cannot simply be transferred unchanged.
Applications include determining acid content in vinegar and other products, measuring acidity in oils, analyzing acid or base purity, and monitoring industrial process solutions.
Environmental measurements often report titratable acidity or alkalinity relative to a specified endpoint. These are operationally defined quantities: they measure the sample’s capacity to react with base or acid under stated conditions, rather than its initial pH alone. Two samples with the same initial pH can require very different amounts of titrant because their buffering capacities differ.
Limitations and uncertainty
Acid–base titration measures reactive capacity, not necessarily the concentration of one uniquely identified compound. Other acids, bases, dissolved gases, or substances that react during the procedure can contribute to titrant consumption. Selective sample preparation or an independent analytical method may be required to distinguish components.
Important contributions to measurement uncertainty include:
- Uncertainty in the standardized titrant concentration.
- Sample-volume and delivered-volume measurements.
- Endpoint detection and the difference between endpoint and equivalence.
- Incomplete dissolution, slow reaction, or competing reactions.
- Carbon dioxide absorption or loss.
- Temperature changes and evaporation.
- Nonrepresentative sampling.
Dilute solutions generally have less pronounced pH changes near equivalence and are more sensitive to impurities and atmospheric carbon dioxide. Concentrated solutions can show substantial departures from ideal behavior. Reliable interpretation therefore depends on matching the reaction model, endpoint method, and sample conditions to the quantity being measured.