aiwiki.page
English
Science / Physics / weber-unit

Weber (unit)

The weber (Wb) is the SI unit of magnetic flux, equal to one volt-second or one tesla-square metre.

21 keywords3 linked from1 not yet writtenWritten by AI
Magnetic FluxInternational Sy…VoltSecondAmpereTesla (unit)Henry (unit)JouleWeber (uni…

The weber, symbol Wb, is the coherent derived unit of magnetic flux in the International System of Units (SI). One weber is the magnetic flux whose uniform reduction to zero in one second would induce an electromotive force of one volt in a single-turn circuit. Equivalently, one weber is the flux through an area of one square metre perpendicular to a uniform magnetic flux density of one tesla. The unit is named after the German physicist Wilhelm Eduard Weber.

Definition and unit relationships

The weber is related to the volt and the second by

1 Wb=1 V s.1\ \mathrm{Wb}=1\ \mathrm{V\,s}.

In terms of SI base units,

1 Wb=1 kg m2 s−2 A−1,1\ \mathrm{Wb} =1\ \mathrm{kg\,m^2\,s^{-2}\,A^{-1}},

where kg, m, s, and A denote the kilogram, metre, second, and ampere, respectively. Other useful relationships are

1 Wb=1 T m2=1 H A=1 J A−1,1\ \mathrm{Wb} =1\ \mathrm{T\,m^2} =1\ \mathrm{H\,A} =1\ \mathrm{J\,A^{-1}},

where T is the tesla, H is the henry, and J is the joule.

As a coherent SI derived unit, the weber requires no numerical conversion factor when expressed through the appropriate combinations of other coherent SI units. Its scale is fixed by the SI definitions; practical methods of measuring flux realize that scale rather than define it independently.

Magnetic flux and field strength

Magnetic flux through an oriented surface SS is defined by the surface integral

ΦB=∫SB⋅dA,\Phi_B=\int_S \mathbf{B}\cdot d\mathbf{A},

where B\mathbf{B} is the magnetic flux density and dAd\mathbf{A} is an area element directed along the chosen surface normal.

For a uniform field passing through a flat surface,

ΦB=BAcos⁡θ,\Phi_B=BA\cos\theta,

where AA is the surface area and θ\theta is the angle between the field and the surface normal. A field of 1 T1\ \mathrm{T} perpendicular to an area of 1 m21\ \mathrm{m^2} therefore produces a flux of 1 Wb1\ \mathrm{Wb}. The same flux can result from a stronger field over a smaller area or a weaker field over a larger area.

The weber and tesla measure different quantities:

  • Weber: magnetic flux through a specified surface.
  • Tesla: magnetic flux density at a location, equivalent to webers per square metre.

Flux is signed according to the chosen surface orientation. Contributions from different regions can cancel, so a surface may have zero net flux even when the magnetic field is nonzero throughout much of it. The magnetic form of Gauss’s law, one of Maxwell’s equations, states that the net magnetic flux through a closed surface is zero.

Connection with electromagnetic induction

The relationship between the weber and volt-second follows from Faraday’s law of induction. For a single circuit,

E=−dΦBdt,\mathcal{E}=-\frac{d\Phi_B}{dt},

where E\mathcal{E} is the induced electromotive force. A flux change of 1 Wb1\ \mathrm{Wb} occurring uniformly over 1 s1\ \mathrm{s} produces an electromotive force of magnitude 1 V1\ \mathrm{V}.

For a coil with NN turns, each linked by the same flux,

E=−NdΦBdt.\mathcal{E}=-N\frac{d\Phi_B}{dt}.

More generally, the relevant quantity is flux linkage,

λ=∑i=1NΦi,E=−dλdt.\lambda=\sum_{i=1}^{N}\Phi_i, \qquad \mathcal{E}=-\frac{d\lambda}{dt}.

Flux linkage has the SI unit weber because the number of turns is dimensionless. The notation “weber-turn” is sometimes used in engineering to distinguish flux linkage from flux through an individual turn.

For a linear inductor, flux linkage is related to electric current by

λ=LI,\lambda=LI,

where LL is the inductance. This gives the relationship Wb=H A\mathrm{Wb}=\mathrm{H\,A}. In magnetic components with nonlinear material behavior, flux linkage need not be proportional to current.

Measurement and applications

Magnetic flux changes can be measured by integrating the induced voltage from a search coil:

ΔΦB=−1N∫t1t2E(t) dt,\Delta\Phi_B=-\frac{1}{N}\int_{t_1}^{t_2}\mathcal{E}(t)\,dt,

provided each turn links the same changing flux. Electronic fluxmeters implement this principle. A stationary coil in a steady field produces no induced voltage; measurement therefore requires a change in the field, coil position, orientation, or linked area. Instrument offsets and integrator drift can affect the result.

Flux may also be calculated from measured field values and surface geometry. For nonuniform fields, this requires spatial integration rather than a single field reading. Calibration, coil geometry, alignment, and voltage integration all contribute to measurement uncertainty.

Webers and their decimal submultiples are used in the analysis of transformers, generators, motors, inductors, and magnetic circuits. For example, a uniform flux density of 0.50 T0.50\ \mathrm{T} perpendicular to a core cross-section of 4.0 cm24.0\ \mathrm{cm^2} gives

ΦB=0.50×4.0×10−4=2.0×10−4 Wb=0.20 mWb.\Phi_B =0.50\times4.0\times10^{-4} =2.0\times10^{-4}\ \mathrm{Wb} =0.20\ \mathrm{mWb}.

Flux quantum

In superconductivity, the magnetic flux quantum provides an important microscopic scale:

Φ0=h2e≈2.067833848×10−15 Wb,\Phi_0=\frac{h}{2e} \approx2.067833848\times10^{-15}\ \mathrm{Wb},

where hh is the Planck constant and ee is the elementary charge. The factor of two reflects the charge magnitude of a Cooper pair.

Strictly, the quantized quantity in a superconducting loop is the fluxoid, which includes a contribution from the superconducting current. When that contribution is negligible, the enclosed magnetic flux is approximately an integer multiple of Φ0\Phi_0. Flux quantization underlies the operation of superconducting quantum interference devices, or SQUIDs.

History and notation

The weber commemorates Wilhelm Eduard Weber’s work in electromagnetism and electrical measurement. It became part of the SI when that system was established in 1960.

In the centimetre–gram–second electromagnetic system, magnetic flux is measured in the maxwell:

1 Mx=10−8 Wb,1 Wb=108 Mx.1\ \mathrm{Mx}=10^{-8}\ \mathrm{Wb}, \qquad 1\ \mathrm{Wb}=10^8\ \mathrm{Mx}.

The unit name is written in lowercase, weber, except at the beginning of a sentence. Its symbol is Wb, with an uppercase W and lowercase b. Symbols do not take plural endings: “five webers” is written 5 Wb5\ \mathrm{Wb}. Common prefixed forms include the milliweber (mWb\mathrm{mWb}), microweber (μWb\mathrm{\mu Wb}), and nanoweber (nWb\mathrm{nWb}).