The henry, symbol H, is the International System of Units (SI) derived unit of inductance, including both self-inductance and mutual inductance. An ideal circuit element has an inductance of one henry when a current changing at one ampere per second produces an induced voltage of one volt. The unit is named after the American physicist Joseph Henry, who investigated electromagnetic induction.
Definition and unit relationships
The henry is a coherent SI derived unit: it can be expressed in other SI units without an additional numerical factor:
Here V denotes the volt, Wb the weber, and the ohm. In SI base units, the expression uses the kilogram, metre, second, and ampere.
The dimensional formula is therefore
where the symbols on the right represent the dimensions of mass, length, time, and electric current. The on the left denotes inductance, not length.
Like other SI units named after people, henry is written in lowercase except at the beginning of a sentence, while its symbol is capitalized. The symbol is not pluralized: “five henries” is written , not “5 Hs.”
Physical meaning
Self-inductance
A changing electric current produces a changing magnetic field. Through electromagnetic induction, this change generates an electromotive force that opposes the change in current.
For a linear inductor with constant inductance , its terminal voltage under the passive sign convention is
Thus, a inductor carrying a current that increases at has a terminal voltage of . The corresponding induced electromotive force is written with a minus sign,
to express the opposition described by Faraday’s law of induction and Lenz’s law.
Inductance can also be defined through magnetic flux linkage:
For a winding of turns, each linked by the same magnetic flux , the flux linkage is . One henry therefore corresponds to one weber of flux linkage per ampere. The number of turns is dimensionless.
Mutual inductance
Mutual inductance describes the coupling between circuits: a changing current in one circuit induces a voltage in another. For fixed geometry and linear magnetic behavior, the magnitude of the induced voltage is
where , measured in henries, is the mutual inductance. Its sign depends on the chosen winding orientations and reference directions. Mutual inductance is central to the operation of transformers.
Energy and alternating-current behavior
For an ideal linear inductor, the stored magnetic energy is
A inductor carrying stores , with energy measured in joules. This expression assumes that the inductance is independent of current.
In sinusoidal alternating-current operation, an ideal inductor has impedance
where and . Its inductive reactance is , measured in ohms. Inductance and resistance are therefore distinct quantities: inductance characterizes magnetic energy storage, whereas resistance characterizes dissipation. Real coils generally exhibit both.
Prefixes and practical scales
Common submultiples include:
| Unit | Symbol | Value |
|---|---|---|
| Millihenry | mH | |
| Microhenry | µH | |
| Nanohenry | nH |
Power-supply inductors commonly have values in the microhenry or millihenry range. Radio-frequency circuits often involve nanohenries or microhenries, including unintended inductance in wires and circuit-board traces. Some transformer windings and low-frequency chokes have inductances measured in henries.
These ranges are illustrative rather than defining limits. Inductance depends on conductor geometry, winding arrangement, magnetic materials, and the surrounding electromagnetic environment.
Measurement and real-component limitations
Inductance is commonly measured with impedance bridges, LCR meters, or impedance analyzers. These instruments determine a component’s response to an applied signal and infer an inductance using an equivalent-circuit model.
A measured value may depend on frequency, signal amplitude, direct-current bias, and temperature. Magnetic-core saturation can make flux linkage nonlinear in current. In that case, the ratio and the differential inductance need not be equal.
Real inductors also have winding resistance, magnetic losses, and parasitic capacitance. Near their self-resonant frequency, a single ideal inductance no longer adequately describes their behavior. Precision measurements consequently require stated test conditions, calibration, and an assessment of measurement uncertainty.
Historical development
Joseph Henry and Michael Faraday independently investigated electromagnetic induction in the early nineteenth century. Henry’s work included studies of self-induction.
The name henry was adopted for the practical unit of inductance at the International Electrical Congress held in Chicago in 1893. It subsequently became part of the SI when that system was established in 1960. Historical electrical standards distinguished practical, international, and absolute realizations of electrical units; the modern henry is defined through its coherent relationship to SI units rather than by a particular coil or material artifact.