Mutual inductance is a property of two electrical circuits that describes how the magnetic flux produced by an electric current in one circuit links the other. When that current changes, the linked flux changes and induces an electromotive force in the second circuit. Mutual inductance is a central quantity in electromagnetic induction and underlies the operation of transformers, inductive sensors, and many wireless power systems. Its symbol is usually , and its SI unit is the henry (H), the same unit used for self-inductance.
Definition and physical basis
A current in a circuit produces a magnetic field. Some of that field may pass through a second circuit. For a receiving coil, the relevant quantity is its flux linkage: the sum of the magnetic fluxes through its individual turns.
Let denote the flux linkage of circuit 2 produced by current in circuit 1. In a linear magnetic system with fixed geometry,
Thus,
If the same flux links every turn of an -turn receiving coil, then
The distinction between flux and flux linkage is important: a multiturn coil can have a large induced voltage even when the flux through each turn is modest.
By Faraday’s law of induction, the electromotive force induced in circuit 2 is
For constant mutual inductance,
The minus sign expresses Lenz’s law: the induced effect opposes the change in linked flux. Actual voltage polarity also depends on the chosen winding orientations and terminal references.
One henry of mutual inductance produces an induced electromotive-force magnitude of one volt when the current in the other circuit changes at one ampere per second.
A constant current does not induce a sustained electromotive force in a stationary receiving circuit with fixed magnetic properties. If the geometry changes, however, induction can occur even with constant source current:
This second term is important in moving-coil devices and position-sensitive inductive systems.
Reciprocity and coupled-circuit equations
For ordinary stationary circuits in linear, reciprocal magnetic media,
This reciprocity means that the flux linkage produced in circuit 2 per unit current in circuit 1 equals the corresponding quantity when the source and receiving circuits are exchanged. It does not require identical coils, equal turn counts, or equal self-inductances.
Using consistent winding references, the total flux linkages of two coupled circuits are
where and are their self-inductances. For constant parameters, the terminal voltages under the passive sign convention are
where and represent winding resistance.
The positive derivative terms in these terminal-voltage equations do not contradict the negative sign in Faraday’s law. Terminal voltage drops and induced electromotive forces use different reference conventions.
Polarity and the dot convention
Circuit diagrams commonly place a dot at one terminal of each winding. If a current entering the dotted terminal of one winding increases, it induces a voltage that makes the dotted terminal of the other winding positive relative to its undotted terminal.
When both reference currents enter dotted terminals and both voltages are measured from dotted to undotted terminals, the mutual terms are positive. Reversing one winding reference reverses their signs.
Mutual inductance is therefore a signed quantity once circuit orientations are specified. Some treatments instead reserve for its nonnegative magnitude and show polarity separately.
Coupling coefficient and magnetic energy
The coupling coefficient describes mutual inductance relative to the two self-inductances:
For a passive, linear, reciprocal two-circuit system,
Values near zero indicate weak net coupling. A value of one represents ideal coupling, with no leakage in the coupled-inductor model. Real devices generally have , because some flux links only one winding.
The bound follows from the stored magnetic energy:
For this expression to remain nonnegative for all possible currents,
The mutual term can be positive or negative, depending on the relative currents and winding orientations. The total energy remains nonnegative.
Mutual inductance and coupling coefficient describe different aspects of a device. Two pairs of coils can have the same coupling coefficient but very different mutual inductances because their self-inductances differ.
Dependence on geometry and materials
Mutual inductance depends on coil dimensions, number of turns, separation, relative orientation, and the magnetic properties of surrounding materials.
Coupling is generally stronger when coils share a substantial magnetic-flux path. Increasing separation usually reduces it. Particular arrangements, such as suitably centered perpendicular coils, can have zero net mutual inductance through symmetry and cancellation, even though each coil lies in a nonzero magnetic field.
A high-permeability core can guide flux through both windings and substantially increase mutual inductance. In ferromagnetic materials, however, saturation and hysteresis can make flux linkage nonlinear and dependent on magnetic history.
Ideal long solenoids
For two long, closely coupled solenoids sharing a uniform core of cross-sectional area , magnetic path length , and constant permeability , an ideal approximation is
This neglects end effects, leakage flux, and variations in the core properties.
Neumann’s formula
For two separate, closed, thin-wire loops in free space, mutual inductance can be calculated using Neumann’s formula:
Here is the permeability of free space, and the integration directions specify the loop orientations. The formula makes reciprocity explicit: exchanging the two loops leaves the result unchanged. Magnetic cores and complex conductor geometries usually require other analytical approximations or numerical field calculations.
Alternating-current behavior and applications
For sinusoidal alternating current at angular frequency , the mutual contribution to the receiving winding’s terminal voltage can be written in phasor form as
with the sign determined by winding references and . The mutual impedance is therefore proportional to frequency within the range where a constant-parameter circuit model remains valid.
Transformers
A transformer uses mutual induction to transfer electrical energy between windings. In the ideal limit, shared time-varying flux gives a voltage-magnitude ratio
A load connected to the secondary changes the secondary current, which in turn affects the primary through mutual coupling. Transformer behavior therefore involves both directions of interaction, not merely an imposed primary current inducing a secondary voltage.
Wireless power and sensing
Inductive power-transfer systems use coupled coils to deliver energy without a conductive connection. Coil alignment, separation, losses, and frequency all affect performance. Resonant circuits can improve transfer under some coupling conditions, but mutual inductance alone does not determine efficiency.
Inductive sensors use changes in coupling to detect displacement, rotation, or the presence of conducting or magnetic objects. Current transformers and Rogowski coils use induction to measure changing currents.
Unwanted coupling
Mutual inductance also produces unwanted interference between neighboring circuits. Rapidly changing currents can induce voltages in nearby signal loops. Reducing loop area, increasing separation, and controlling conductor orientation can reduce this magnetic coupling.
Measurement
A common measurement method connects two coils in series, first with their fluxes aiding and then opposing. In the linear, low-loss approximation,
Consequently,
Another method drives one winding with a known sinusoidal current and measures the open-circuit voltage of the other:
These methods require suitable test frequencies and corrections where winding resistance, core losses, loading, or parasitic capacitance are significant. Precision measurements must also account for coil position and measurement uncertainty.
Historical development and model limitations
Mutual induction emerged from the nineteenth-century discovery of electromagnetic induction, notably Michael Faraday’s experiments in 1831. The mathematical treatment of coupled circuits subsequently became part of classical electromagnetism and electrical engineering.
A single constant is most useful for fixed geometry, linear materials, and frequencies at which a lumped-circuit description is adequate. Important departures include:
- Nonlinearity: saturation makes flux linkage depend nonlinearly on the currents. Local behavior may instead be described by an incremental coefficient, such as , with other state variables held fixed.
- Hysteresis and losses: magnetic history, eddy currents, and dissipative material responses complicate the relationship between current and flux.
- Frequency dependence: current redistribution and parasitic capacitance can make measured coupling frequency-dependent.
- Distributed electromagnetic effects: when circuit dimensions are no longer small relative to wavelength, propagation and radiation may require a full field description based on Maxwell’s equations.
- Nonreciprocal media: biased magnetic materials can fall outside the assumptions supporting .
In these regimes, a constant mutual inductance may remain a useful approximation over a restricted operating range, but it no longer completely describes the interaction.