A synchronous reluctance motor is an electric motor that produces torque because its rotor offers different resistance to magnetic flux along different directions. It is a type of synchronous motor: during steady operation, the rotor turns at the same speed as the rotating magnetic field produced by the stator. A conventional, unassisted synchronous reluctance rotor has neither permanent magnets nor electrically excited windings. Modern industrial versions generally operate from a variable-frequency drive, which controls the stator currents to produce and regulate torque.
Operating principle
Magnetic reluctance and rotor saliency
Magnetic reluctance describes how strongly a magnetic circuit opposes the establishment of magnetic flux. An iron path generally has much lower reluctance than a comparable air path. A synchronous reluctance motor exploits this difference by giving its rotor a directionally dependent magnetic structure, called magnetic saliency.
The low-reluctance direction is conventionally called the direct axis, or -axis. The perpendicular, higher-reluctance direction is the quadrature axis, or -axis. The stator winding consequently has a higher effective inductance along the direct axis than along the quadrature axis.
When the stator establishes a magnetic field, the rotor experiences a torque tending to align its low-reluctance axis with that field. Continuous rotation results when the field rotates and the rotor follows it with a controlled angular displacement. Exact alignment is not the normal torque-producing condition: a suitable displacement between the rotor axis and the stator excitation is necessary to sustain load torque.
Unlike an induction motor, a synchronous reluctance motor does not depend on sustained slip and induced rotor currents to produce its principal torque.
Torque equation
For an idealized three-phase machine with sinusoidal windings, the electromagnetic torque can be written as
where:
- is electromagnetic torque;
- is the number of pole pairs;
- and are stator-current components in a rotor-aligned reference frame;
- and are the corresponding stator flux linkages.
For an unsaturated, magnet-free motor with constant axis inductances,
giving
These expressions use the common amplitude-invariant coordinate transformation, under which the current-vector magnitude corresponds to peak phase current for balanced sinusoidal operation.
The equation shows that torque requires both magnetic anisotropy, represented by , and appropriate current components on both axes. The saliency ratio, , is an important design measure, although it does not by itself determine motor performance.
In a real motor, magnetic saturation makes flux linkage a nonlinear function of current. Cross-saturation also means that current on one axis affects the magnetic behavior of the other. Accurate control therefore often uses measured or calculated flux-linkage maps rather than fixed inductances.
Synchronous speed
The mechanical synchronous speed is
where is in revolutions per minute and is the electrical supply frequency in hertz. A four-pole motor, with two pole pairs, has a synchronous speed of 1,500 revolutions per minute at 50 hertz.
Frequency determines synchronous speed, while current magnitude and orientation determine torque within the machine’s operating limits.
Construction
The stator usually resembles that of a conventional industrial alternating-current motor, with a laminated steel core and distributed windings supplied by three-phase electric power.
The distinctive component is the rotor. Common constructions include:
- Transversely laminated rotors. Thin electrical-steel laminations are stacked along the shaft. Each lamination contains internal slots or cavities, known as flux barriers, that impede quadrature-axis flux while retaining lower-reluctance direct-axis paths.
- Axially laminated anisotropic rotors. Alternating magnetic and nonmagnetic layers extend along the rotor axis. Such structures can provide strong anisotropy, but their manufacture and mechanical integration can be more demanding.
- Simple salient-pole rotors. Shaped poles create directional reluctance without elaborate internal barriers. These appear in some smaller or specialized machines.
Flux-barrier rotors require narrow bridges and ribs to hold the structure together. These features create a design compromise: thicker bridges improve mechanical strength but can allow unwanted magnetic flux across the barriers. Rotor geometry must balance torque, power factor, torque ripple, manufacturability, and allowable speed.
Laminations reduce rotor eddy-current losses caused by time-varying flux components. Although the fundamental field is approximately stationary relative to the synchronously rotating rotor, slotting, spatial harmonics, and inverter switching still produce changing fields and associated losses.
Starting and control
Inverter-fed operation
A conventional magnet-free synchronous reluctance motor without a starting cage is not inherently self-starting when connected directly to a fixed-frequency supply. Industrial systems therefore normally use a variable-frequency drive containing a power inverter.
The drive establishes the desired stator-current orientation and accelerates the rotor from rest while maintaining controlled operation. Motor parameters and suitable control software are important; a drive configured only for an induction motor may not provide satisfactory synchronous reluctance control.
Field-oriented control regulates direct- and quadrature-axis currents separately. Below the voltage limit, control commonly seeks maximum torque per ampere, reducing the current required for a specified torque. In the ideal constant-inductance model, maximum torque for a fixed current magnitude occurs when the two current components have equal magnitudes. Saturation generally shifts the practical optimum.
At higher speeds, available inverter voltage limits the operating region. Field-weakening control adjusts the current vector to constrain flux linkage and extend the speed range, subject to voltage, current, thermal, and mechanical limits.
Position feedback and sensorless control
Rotor orientation can be measured with a shaft-position sensor, such as an encoder or resolver, or estimated from electrical measurements.
Sensorless methods may use voltage and current models at moderate and high speeds. At low speed or standstill, where induced-voltage information becomes weak, high-frequency signal injection can exploit rotor saliency to estimate axis orientation. Performance depends on saturation, inverter behavior, measurement quality, and the estimation method.
Line-start variants
A line-start synchronous reluctance motor adds a squirrel-cage structure to the rotor. The cage produces induction torque during acceleration; the rotor then pulls into synchronism under suitable load and supply conditions.
This arrangement permits direct connection to a fixed-frequency supply, but successful starting depends on load torque, inertia, voltage, and rotor design. The cage also changes losses and construction, distinguishing the machine from a pure inverter-fed synchronous reluctance motor.
Distinction from related motors
| Motor type | Principal torque mechanism | Main distinction |
|---|---|---|
| Induction motor | Interaction between the stator field and slip-induced rotor currents | Normally requires nonzero slip to produce motoring torque |
| Permanent-magnet synchronous motor | Interaction between stator excitation and rotor permanent-magnet flux, often supplemented by reluctance torque | Uses permanent magnets |
| Switched reluctance motor | Sequential excitation of stator phases acting on a salient rotor | Typically uses concentrated windings, doubly salient construction, and position-dependent switching |
| Synchronous reluctance motor | Interaction between stator excitation and rotor magnetic anisotropy | Pure versions require neither rotor magnets nor rotor excitation windings |
A switched reluctance motor therefore belongs to the broader reluctance-machine family but is not interchangeable with a conventional synchronous reluctance motor. Their winding arrangements, waveforms, converters, and control strategies usually differ.
Permanent-magnet-assisted synchronous reluctance motors place magnets within the flux-barrier structure. Magnets can improve torque production and power factor, but introduce magnet-related costs, material requirements, and temperature limits. The boundary between this category and an interior permanent-magnet synchronous motor is not absolute: both can combine magnet torque with reluctance torque.
Efficiency and performance
The absence of torque-producing rotor currents eliminates the rotor copper or cage losses characteristic of induction operation. This can reduce rotor heating and improve efficiency, particularly in appropriately designed variable-speed systems.
Nevertheless, a synchronous reluctance motor is not loss-free. Important losses include stator winding resistance losses, magnetic core losses, harmonic rotor losses, bearing friction, and windage. Inverter losses must also be included when assessing the complete drive system.
Principal trade-offs include:
- Power factor. Magnetizing current is supplied through the stator. Motor-side power factor can therefore be lower than that of comparable permanent-magnet machines, increasing the current rating required from the inverter. It should not be confused with the power factor measured at the drive’s mains input.
- Torque density. Performance depends strongly on magnetic anisotropy, saturation, cooling, and mechanical constraints. Modern designs can provide high output, but do not universally exceed permanent-magnet or induction alternatives.
- Torque ripple and noise. Rotor barriers, stator slots, current harmonics, and saturation can create pulsating torque and electromagnetic forces. Geometry optimization, skewing, and current control can mitigate these effects.
- Mechanical strength. Internal barriers reduce the amount of material available to carry centrifugal loading, especially at high speed.
- Control requirements. Good performance requires appropriate rotor-angle estimation, current regulation, and magnetic characterization.
Eliminating permanent magnets avoids magnet demagnetization and dependence on permanent-magnet materials for the rotor. It does not remove thermal limits imposed by winding insulation, bearings, lubricants, and structural materials.
Development and applications
Reluctance torque has long been recognized in electrical-machine theory. Earlier synchronous reluctance designs were constrained by modest rotor saliency, limited starting arrangements, and less capable control equipment. Improvements in power electronics, digital control, electromagnetic modeling, and flux-barrier manufacturing enabled wider industrial use.
Applications include pumps, fans, compressors, conveyors, and other variable-speed machinery. Building services such as air-conditioning systems are relevant because long operating hours can make drive-system efficiency important.
Suitability depends on the complete duty cycle rather than rated efficiency alone. Relevant factors include part-load losses, required starting torque, speed range, noise, cooling, available inverter capacity, and integration with process control. Replacing an existing motor also requires checking mechanical interfaces and drive compatibility; a synchronous reluctance motor is not necessarily a direct replacement for a line-connected induction motor.