Transmittance is the ratio of radiant power transmitted through a material, surface, or optical system to the radiant power incident upon it. It describes how much electromagnetic radiation passes through an object rather than being reflected, absorbed, or redirected outside the measured transmission path. A central quantity in optics and spectroscopy, transmittance depends on wavelength, material thickness, illumination geometry, and the directions in which transmitted radiation is collected.
Definition and notation
Transmittance is commonly written as or :
where is transmitted radiant power and is incident radiant power. It is dimensionless and may be expressed as a fraction or percentage:
A transmittance of , for example, means that 80% of the incident radiant power is transmitted under the stated measurement conditions.
For a passive sample, with no additional radiation generated or introduced into the measurement, transmittance lies between zero and one. Optical amplification, sample emission, or an inappropriate reference measurement can produce a measured ratio greater than one; such a result requires interpretation beyond ordinary passive transmittance.
Transmittance is not generally a single intrinsic constant of a substance. A complete specification may need to include:
- Wavelength or wavelength range.
- Sample thickness and surface condition.
- Angle of incidence.
- Polarization of the incident radiation.
- The surrounding media.
- Whether only the direct beam or all forward-transmitted radiation is collected.
Spectral and broadband transmittance
Spectral transmittance specifies the transmitted fraction at a particular wavelength:
A transmission spectrum plots this quantity across part of the electromagnetic spectrum. A material can transmit strongly in one spectral region and weakly in another; visible transparency therefore does not imply infrared or ultraviolet transparency.
For a wavelength-preserving system, broadband radiant transmittance is a source-weighted average:
Consequently, two sources with different spectra can yield different broadband transmittances for the same sample. A detector that is not spectrally corrected introduces its own wavelength-dependent weighting.
Reflection, absorption, and scattering
Radiation incident on a material may be transmitted, reflected, or absorbed. For a passive, non-emitting sample in a steady-state measurement, conservation of energy gives
where is reflectance and is absorptance. Here, the transmitted and reflected powers must include all relevant outgoing directions, rather than only narrow beams.
Reflection occurs at interfaces and can reduce transmittance even when a material absorbs almost no radiation. Scattering redistributes radiation among directions: forward-scattered radiation may still count as transmitted, while backward-scattered radiation contributes to reflection. Whether scattered light reaches the detector therefore strongly affects the reported transmittance.
Regular, diffuse, and total transmittance
Regular or direct transmittance describes the component transmitted in the geometrically expected beam direction, excluding diffusely transmitted light.
Diffuse transmittance describes the component transmitted into a spread of directions through scattering.
Total transmittance includes both regular and diffuse transmission. For a specified incident direction, a measurement collecting all radiation emerging into the forward hemisphere is a directional–hemispherical transmittance.
A frosted pane can have high total transmittance but low regular transmittance: it admits substantial light while preventing a clear view. The distinction is important for translucent plastics, paper, clouds, suspensions, and other scattering media. Exact measurement standards can differ in the angular boundary used to separate regular from diffuse transmission.
Internal and external transmittance
Internal transmittance characterizes transmission through the interior of a material, with surface reflection losses excluded. External transmittance includes the effects of the sample boundaries as well as propagation through the material.
This distinction matters when comparing bulk optical materials. Two samples with identical internal attenuation can have different external transmittances because of surface coatings, surrounding media, or differences in refractive index.
Exponential attenuation and absorbance
In a homogeneous absorbing medium, monochromatic radiation often follows the Beer–Lambert law:
so that internal transmittance is
Here, is the path length and is the absorption coefficient, with units of inverse length. This expression assumes conditions in which a constant absorption coefficient is appropriate, without complications such as saturation or significant radiation entering the detected beam from other directions.
For a spatially varying coefficient,
For the unscattered component in a medium that both absorbs and scatters, an analogous expression uses an extinction coefficient that includes absorption and scattering out of the direct beam. It does not, in general, describe total transmitted power, because some scattered radiation may still emerge on the transmission side.
Absorbance is not absorptance
Absorbance is a logarithmic quantity:
Thus, corresponds to an absorbance of 1, and to an absorbance of 2.
Absorbance must be distinguished from absorptance, the fraction of incident power actually absorbed. A low measured transmittance can result from reflection or scattering as well as absorption. Interpreting absorbance as a measure of absorption therefore requires suitable measurement conditions and reference corrections.
For a dilute absorbing solution under Beer–Lambert conditions,
where is the molar absorption coefficient, is molar concentration, and is the optical path length. Consistent units are required. Deviations can arise from chemical changes, high concentrations, scattering, broad spectral bandwidth, and instrumental stray light.
Interfaces, polarization, and interference
Transmission at a smooth interface is governed by the Fresnel equations. At normal incidence between two lossless, nonmagnetic media with real refractive indices and , reflectance is
For this single nonabsorbing interface, . A finite plate has at least two interfaces, and its total transmission must also account for internal reflections and any bulk absorption.
Power transmittance must not be confused with the amplitude transmission coefficient , which relates electric-field amplitudes. For a plane wave crossing a single interface between lossless, nonmagnetic media,
where and are the incident and transmitted angles. The prefactor accounts for the relationship between field amplitude and energy flow normal to the interface.
At oblique incidence, transmission generally differs between the two linear polarizations defined relative to the plane of incidence. Under total internal reflection at an ideal, isolated lossless interface, there is no net transmitted power propagating away into the second medium, although an evanescent field exists there.
In thin films and multilayer coatings, interference between multiply reflected waves can enhance or suppress transmission at selected wavelengths. Antireflection coatings, interference filters, and resonant optical cavities exploit this behavior. Transmission through several layers is therefore not always the simple product of their separately measured transmittances.
Measurement
A typical transmittance measurement compares a detector signal obtained with a sample to a reference signal obtained without it, or with an appropriate blank. After subtracting dark signals,
This ratio represents transmittance only insofar as detector response is linear and the illumination and collection conditions are suitably controlled.
A spectrophotometer measures transmission as a function of wavelength. In solution spectroscopy, a reference cell containing the solvent can compensate for much of the transmission loss associated with the solvent and cell. An integrating sphere collects radiation over a wide range of directions and is commonly used to measure total transmittance in scattering samples.
Important sources of measurement uncertainty include:
- Stray light, which can make strongly attenuating samples appear too transmissive.
- Detector nonlinearity, noise, or saturation.
- Source drift and imperfect reference correction.
- Finite spectral bandwidth and wavelength errors.
- Beam alignment, sample positioning, and collection angle.
- Surface contamination, sample inhomogeneity, and thickness variation.
Calibration and a clear statement of measurement geometry are essential when comparing results from different instruments.
Applications and related quantities
Transmittance is used to specify optical windows, lenses, filters, coatings, protective glazing, and display components. For architectural glazing, visible transmittance is distinct from total solar-energy transmission: visible appearance alone does not establish how much solar energy passes through a pane.
In analytical chemistry, transmission spectra reveal wavelength-dependent molecular absorption and support concentration measurements. In infrared spectroscopy, transmission features can identify vibrational absorption bands.
Atmospheric transmittance describes the fraction of radiation passing through a path in the atmosphere. Absorption by gases and scattering by molecules, aerosols, and clouds determine spectral transmission windows. When multiple scattering is important, radiative transfer methods are needed to describe total radiation transport rather than only direct-beam attenuation.
Several related quantities describe transmission on different scales:
- Optical depth, usually denoted , is defined for exponential direct-beam attenuation by . Because is also sometimes used for transmittance, notation must be stated explicitly.
- Attenuation in decibels for a power ratio is .
- Luminous transmittance weights spectral transmission by the incident spectrum and a specified visual-response function, rather than treating all wavelengths equally.
- Transparency is a broader descriptive term associated with seeing through a material; it is not equivalent to high total transmittance.