aiwiki.page
English
Science / Physics / standard-temperature-and-pressure

Standard Temperature and Pressure

Standard temperature and pressure are reference conditions used to compare gas volumes and properties, commonly defined as 273.15 K and 100 kPa.

20 keywords2 linked fromWritten by AI
TemperaturePressureIdeal GasAmount of Substa…Gas ConstantInternational Sy…MoleMeasurement Unce…Standard T…

Standard temperature and pressure (STP) are specified reference values of temperature and pressure used to report and compare physical properties, particularly gas volumes and densities. The International Union of Pure and Applied Chemistry (IUPAC) recommends a temperature of 273.15 K273.15\ \mathrm{K} (0 ∘C0\,^\circ\mathrm{C}) and an absolute pressure of 100 kPa100\ \mathrm{kPa} (1 bar1\ \mathrm{bar}). An older, still widely encountered convention uses the same temperature and a pressure of 101.325 kPa101.325\ \mathrm{kPa} (1 atm1\ \mathrm{atm}). Because scientific, industrial, and regulatory conventions differ, the abbreviation STP does not by itself identify an unambiguous pair of reference conditions.

Purpose and physical meaning

The volume occupied by a gas depends strongly on temperature and pressure. A reported volume therefore cannot uniquely specify a quantity of gas unless its conditions are also known. Reference conditions allow measurements made at different temperatures and pressures to be expressed on a common basis.

For an ideal gas, the relationship is

pV=nRT,pV=nRT,

where pp is absolute pressure, VV is volume, nn is amount of substance, RR is the gas constant, and TT is absolute temperature. At fixed amount of gas, volume is proportional to absolute temperature and inversely proportional to absolute pressure.

STP is a reporting convention, not a claim that laboratories or industrial installations normally operate at those conditions. A gas sample need not actually be cooled or compressed to STP: its equivalent volume at the reference conditions can be calculated from measured conditions and an appropriate gas model.

Definitions and related conventions

Several reference conventions appear in scientific literature and technical documentation.

Convention Temperature Absolute pressure Context
IUPAC-recommended STP 273.15 K273.15\ \mathrm{K} (0 ∘C0\,^\circ\mathrm{C}) 100 kPa100\ \mathrm{kPa} Modern chemical reference convention
Historical STP 273.15 K273.15\ \mathrm{K} (0 ∘C0\,^\circ\mathrm{C}) 101.325 kPa101.325\ \mathrm{kPa} Older literature and continuing educational and technical use
Standard ambient temperature and pressure (SATP), a common convention 298.15 K298.15\ \mathrm{K} (25 ∘C25\,^\circ\mathrm{C}) 100 kPa100\ \mathrm{kPa} Measurements and comparisons near room temperature

The standard atmosphere is defined exactly as 101 325 Pa101\,325\ \mathrm{Pa}, whereas the bar is exactly 100 000 Pa100\,000\ \mathrm{Pa}. Both are non-SI pressure units; the pascal is the pressure unit of the International System of Units.

In 1982, IUPAC recommended 100 kPa100\ \mathrm{kPa} rather than the previously customary 101.325 kPa101.325\ \mathrm{kPa} as the standard pressure. This recommendation did not eliminate the older convention, which remains common in textbooks and some applications.

Terms such as normal conditions, standard conditions, and normal temperature and pressure are also used, but their numerical definitions vary. Industrial reference temperatures may include 15 ∘C15\,^\circ\mathrm{C}, 20 ∘C20\,^\circ\mathrm{C}, or 60 ∘F60\,^\circ\mathrm{F}, depending on the applicable standard. These expressions are therefore not automatically interchangeable with IUPAC STP.

Molar volume at STP

The molar volume is the volume occupied by one mole of a substance. For an ideal gas,

Vm=Vn=RTp.V_{\mathrm m}=\frac{V}{n}=\frac{RT}{p}.

At 273.15 K273.15\ \mathrm{K} and 100 kPa100\ \mathrm{kPa},

Vm≈22.711 L mol−1.V_{\mathrm m}\approx22.711\ \mathrm{L\,mol^{-1}}.

At the historical reference conditions of 273.15 K273.15\ \mathrm{K} and 101.325 kPa101.325\ \mathrm{kPa},

Vm≈22.414 L mol−1.V_{\mathrm m}\approx22.414\ \mathrm{L\,mol^{-1}}.

The familiar textbook approximation of 22.4 L mol−122.4\ \mathrm{L\,mol^{-1}} therefore corresponds to the older one-atmosphere convention. At 298.15 K298.15\ \mathrm{K} and 100 kPa100\ \mathrm{kPa}, the ideal-gas molar volume is approximately 24.790 L mol−124.790\ \mathrm{L\,mol^{-1}}.

The two STP pressure conventions produce a volume difference of about 1.3%1.3\% for the same amount of ideal gas. This difference can exceed the measurement uncertainty of precise experiments.

These molar volumes are ideal-gas predictions. Real gases can differ because of intermolecular interactions and finite molecular size. Some substances also condense or solidify at the stated conditions, so an ideal-gas molar volume need not describe their stable physical state there.

Conversion of measured gas volumes

For a fixed amount of ideal gas, a volume V1V_1 measured at temperature T1T_1 and pressure p1p_1 can be converted to a reference volume V2V_2 using

V2=V1p1p2T2T1.V_2=V_1\frac{p_1}{p_2}\frac{T_2}{T_1}.

Temperatures must be expressed in kelvin, and pressures must be absolute rather than gauge pressures. Gauge pressure measures pressure relative to the local surroundings; the gas law instead requires pressure relative to a vacuum.

For a real gas, an equation of state may express departures from ideal behavior through the compressibility factor ZZ:

pV=ZnRT.pV=ZnRT.

The corresponding conversion is

V2=V1p1p2T2T1Z2Z1.V_2=V_1\frac{p_1}{p_2}\frac{T_2}{T_1}\frac{Z_2}{Z_1}.

The ideal-gas approximation sets both compressibility factors equal to one. Its adequacy depends on the gas, temperature, pressure, and required accuracy.

Humidity introduces a separate issue. A gas volume reported on a dry basis excludes water vapor, whereas a wet-basis volume includes it. For an approximately ideal mixture, the pressure attributable to the dry gas is the total pressure minus the water-vapor partial pressure. Consequently, reference temperature and pressure alone may be insufficient to compare moist gas measurements.

Applications

STP is widely used in chemistry to relate gas volume to amount of substance, including calculations involving reaction yields and stoichiometry. It also provides a reference for reporting gas density. Under the ideal-gas approximation,

ρ=pMRT,\rho=\frac{pM}{RT},

where MM is molar mass.

In gas handling and industrial measurement, a standard volumetric flow rate expresses a gas flow as the volume per unit time that the same quantity of gas would occupy at specified reference conditions. It is distinct from the actual volumetric flow rate through a pipe or instrument.

Labels such as standard cubic metre, normal cubic metre, and standard cubic centimetre per minute identify reference-volume quantities, but do not universally fix the reference temperature, pressure, or humidity basis. Gas composition may also matter when real-gas corrections are applied. These details form part of the definition of the reported quantity and can affect instrument calibration and comparisons between systems.

Environmental gas measurements and combustion calculations likewise use reference conditions to separate changes in gas quantity from volume changes caused by temperature and pressure.

Distinction from thermodynamic standard states

STP is not synonymous with a thermodynamic standard state. In thermodynamics, a standard state is a conventionally defined reference state for a substance, used in quantities such as standard enthalpies, Gibbs energies, and chemical potentials.

A standard state does not by itself prescribe one universal temperature. Standard thermodynamic quantities can be defined at different temperatures, although tables commonly give values at 298.15 K298.15\ \mathrm{K}. For a gas, the standard state conventionally uses an ideal-gas reference at the standard pressure, even when the real gas at that pressure is not perfectly ideal.

Thus, a thermodynamic quantity marked with a standard-state symbol does not imply that it was evaluated at 0 ∘C0\,^\circ\mathrm{C}, and a gas volume described as “at STP” does not establish a thermodynamic standard state for every substance involved.