A phasor is a complex number that represents the amplitude and phase of a sinusoid at a specified frequency, with its time dependence factored out. Phasors turn the addition and differentiation of same-frequency sinusoids into algebraic operations. They are widely used in alternating-current circuit analysis, electromagnetism, optics, and other fields involving harmonic oscillations. A phasor is not itself the instantaneous physical quantity: that quantity is recovered by restoring the time-dependent factor and taking the real part.
Mathematical definition
Consider the real sinusoidal quantity
where is its peak amplitude, is its angular frequency, and is its phase relative to a chosen time reference. Euler’s formula gives
where . Electrical engineering conventionally uses rather than , because commonly denotes electric current.
Using peak-amplitude normalization, the phasor associated with is
The reconstruction rule is therefore
The magnitude gives the amplitude, and its argument gives the phase, defined modulo . The phasor does not by itself specify the frequency: must be supplied separately or understood from context. For a zero-amplitude sinusoid, the phase is undefined.
Phasors can be written in either polar or rectangular form:
Polar form is convenient for multiplication and division; rectangular form is convenient for addition and subtraction.
Normalization and sign conventions
In electrical power engineering, phasor magnitudes commonly represent root-mean-square values rather than peak amplitudes. For a sinusoid,
An RMS-normalized phasor is thus
with reconstruction
Peak and RMS conventions are equally valid, but they must not be mixed.
Some fields use instead of , or use sine rather than cosine as the reference waveform. These choices change phase signs and some algebraic formulas without changing the underlying physics. The time convention and amplitude normalization must therefore be stated or established by context.
Geometric interpretation
A phasor can be drawn as an arrow in the complex plane. Its length represents amplitude, and its angle from the positive real axis represents phase. Multiplication by produces a rotating arrow whose projection onto the real axis is the physical sinusoid.
Strictly, the time-independent phasor and the rotating quantity are distinct, although both are sometimes called phasors.
A phasor diagram displays several quantities at one common frequency. Their relative angles show which signals lead or lag others. With the convention, a greater phase angle corresponds to a leading waveform. A time delay produces
so the delay corresponds to a phase shift of .
The arrows are not necessarily spatial vectors. Voltage and current phasors, for example, represent scalar quantities with phase relationships. Spatial vector fields can also be represented by phasors, with a complex amplitude assigned to each component.
Algebra and calculus
Addition and superposition
Sinusoids at the same frequency can be added by adding their phasors:
For example,
have phasors and . Their sum is
and consequently
This is a complex-plane expression of the superposition principle. The common-frequency condition is essential: sinusoids at different frequencies generally cannot be combined into one constant phasor.
Differentiation and integration
For constant ,
Thus a time derivative corresponds to multiplication by :
Higher derivatives correspond to powers of .
For , an indefinite integral has an oscillatory component represented by
An integration constant is a separate zero-frequency contribution and is not contained in that phasor.
These rules explain much of the method’s usefulness: linear differential equations with constant coefficients become algebraic equations for sinusoidal particular solutions.
Electrical circuit analysis
In sinusoidal steady state, electrical impedance relates voltage and current phasors through the frequency-domain form of Ohm’s law:
Using the convention, ideal circuit elements have impedances
where is resistance, is inductance, and is capacitance.
These relations encode both magnitude and phase:
- A resistor’s voltage and current are in phase.
- An ideal inductor’s voltage leads its current by .
- An ideal capacitor’s current leads its voltage by .
Kirchhoff’s circuit laws retain their algebraic form for same-frequency phasors. In a series resistor–inductor–capacitor circuit, for example,
The impedance determines the current amplitude and its phase relative to the applied voltage.
Power calculations
With RMS-normalized voltage and current phasors, complex power is
where the asterisk denotes complex conjugation. Under the passive sign convention, in which current enters the terminal marked positive,
and
Here is average active power and is reactive power. The apparent power is
With peak-amplitude phasors, the corresponding formula instead includes a factor of one-half:
Complex power is a derived quantity, not a phasor representing instantaneous power. The instantaneous product generally contains both a constant component and an oscillation at twice the original frequency.
Fields, waves, and other applications
For a monochromatic electric field, a vector phasor representation is
The phasor can vary with position while remaining independent of time. Substitution into Maxwell’s equations replaces time derivatives by , producing frequency-domain field equations.
In wave optics, phasor addition describes interference between coherent contributions. Relative phase determines whether the resulting amplitude is enhanced or reduced. Complex field components also describe polarization, including elliptical polarization when perpendicular components have suitable amplitude and phase differences.
The same mathematics applies to harmonic sound waves, mechanical vibrations, and frequency-response measurements. In each case, the phasor retains amplitude and phase while suppressing a shared sinusoidal time factor.
Relationship to frequency-domain methods
A phasor describes a single frequency. A Fourier series represents a periodic waveform using a constant term and multiple harmonic frequencies, each of which can be assigned its own complex amplitude. Phasor methods can therefore be applied separately to each harmonic in a suitable linear system, followed by reconstruction of the time-domain waveform.
For a linear time-invariant system, a sinusoidal input produces a sinusoidal particular response at the same frequency. If its transfer function is , then, when a bounded sinusoidal steady-state response exists,
The magnitude of gives the amplitude ratio, and its argument gives the phase shift.
Phasors do not normally describe startup transients or enforce arbitrary initial conditions. Those require additional time-domain terms or more general methods, such as the Laplace transform. In a stable system, decaying transients eventually leave the sinusoidal steady-state response; in an unstable system, that steady-state description may not represent the long-term behavior.
Limitations and historical development
Ordinary constant-phasor analysis assumes a fixed frequency and linear relationships among the quantities being analyzed. Nonlinear elements can generate additional frequencies, while time-varying systems can shift or mix frequencies. Slowly changing amplitudes and phases can be represented by complex envelopes, but those are time-dependent generalizations rather than constant phasors.
Phasor multiplication must also be distinguished from multiplication of physical waveforms. In general,
Products, powers, and other nonlinear operations therefore require separate treatment.
The mathematical basis of phasors lies in complex exponentials and harmonic analysis. Their engineering use became especially important with the development of alternating-current power systems in the late nineteenth century. Charles Proteus Steinmetz helped establish complex-number methods for practical AC calculations, replacing extensive trigonometric manipulation with algebraic circuit analysis.