Electrical admittance is a quantity describing the electric current produced by an applied voltage in a circuit or component. Denoted by , it is the reciprocal of electrical impedance. In sinusoidal steady-state analysis, admittance is generally a complex quantity: its real part is conductance, and its imaginary part is susceptance. These parts describe, respectively, the current component in phase with the voltage and the current component a quarter-cycle out of phase. Admittance is measured in siemens, symbol .
Definition and mathematical form
For a linear circuit driven at a single frequency, admittance is defined as
where and are current and voltage phasors, is impedance, and is angular frequency. A phasor represents the amplitude and phase of a sinusoidal quantity without explicitly carrying its time dependence.
Admittance is written as the complex number
where:
- is conductance, the real part of admittance;
- is susceptance, the imaginary part;
- is the imaginary unit, satisfying .
Electrical engineering commonly uses rather than for the imaginary unit to avoid confusion with current.
The magnitude and phase of admittance are
Consequently,
Thus, admittance specifies both how much current flows for a given voltage and how that current is shifted in phase.
For a purely resistive element under direct current, admittance reduces to ordinary conductance:
where is electrical resistance. This is the conductance form of Ohm’s law.
Units and terminology
The SI unit of admittance, conductance, and susceptance is the siemens:
The older unit name mho, formed by reversing the word ohm, denotes the same quantity and was often represented by an inverted omega symbol. Siemens is the standard modern unit.
Admittance should not be confused with electrical conductivity. Admittance describes the terminal behavior of a particular component or network and depends on its geometry and connections. Conductivity is a material property. For a uniform conductor of length , cross-sectional area , and conductivity , under conditions where a simple resistive model applies,
Conductivity has units of siemens per metre, rather than siemens.
Relationship to resistance and reactance
If impedance is expressed as
where is reactance, taking its reciprocal gives
Therefore,
Conversely,
These relationships show that conductance is not generally the reciprocal of the real part of impedance. The equality holds for a purely resistive impedance, not for an arbitrary complex impedance. Similarly, susceptance is not generally the reciprocal of reactance; for a purely reactive impedance, .
For example, a component with
has admittance
Its admittance magnitude is , and its current lags the applied voltage by approximately .
Ideal circuit elements
The usual engineering convention represents sinusoidal signals using . Under this convention, capacitive susceptance is positive and inductive susceptance is negative.
Resistor
For an ideal resistor,
Admittance is entirely real, and current and voltage are in phase.
Capacitor
For an ideal capacitor with capacitance ,
Its susceptance is
Current leads voltage by , and admittance magnitude increases linearly with frequency. In the steady-state direct-current limit, an ideal capacitor behaves as an open circuit.
Inductor
For an ideal inductor with inductance ,
Its susceptance is
Current lags voltage by , and admittance magnitude decreases as frequency rises. In the ideal direct-current limit, the inductor behaves as a short circuit, although actual inductors have winding resistance and other losses.
If the alternative convention is used, the signs of imaginary quantities reverse. Physical predictions are unchanged when the convention is applied consistently.
Parallel circuits and resonance
Admittance is particularly convenient for parallel circuits because all branches share the same voltage. Branch currents add, so
Conductances and susceptances can therefore be summed separately:
By contrast, impedances add directly for series-connected elements.
For an ideal resistor, capacitor, and inductor connected in parallel,
The capacitive and inductive susceptances cancel at
At this parallel-resonance frequency, the input admittance is purely real. In this particular model, with a constant parallel resistance, admittance magnitude is minimized and impedance magnitude is maximized at resonance.
For a lossless parallel inductor–capacitor circuit, the ideal admittance is zero at resonance. Net terminal current is then zero for a finite applied sinusoidal voltage, even though nonzero currents flow through the individual branches. Real losses prevent the corresponding impedance from becoming infinite.
Admittance and electrical power
For sinusoidal alternating current, admittance provides a direct relationship between terminal voltage and power.
Using root-mean-square phasors and the passive sign convention, in which current enters the terminal labeled positive, complex power is
The asterisk denotes complex conjugation. Since ,
Hence,
Here is average active power and is reactive power. Conductance determines average power absorbed at a specified voltage. Susceptance describes the out-of-phase response associated with periodic energy exchange rather than net energy consumption in ideal reactive elements.
Under this sign convention, an inductive load has and , while a capacitive load has and . A passive one-port cannot supply net average power in sinusoidal steady state; where its admittance is finite, its conductance is therefore nonnegative. Active circuits can exhibit negative conductance over some operating ranges by drawing energy from another source.
Network analysis and applications
Nodal analysis
Admittance is a natural variable in nodal analysis, which applies current balance at circuit nodes. For a branch between nodes and ,
A linear network can consequently be written in matrix form as
where is the nodal admittance matrix. It combines branch admittances and network connectivity.
Admittance matrices are widely used in electrical-grid calculations. A bus admittance matrix represents transmission connections, transformers, and shunt elements. The network relation is linear for a specified model, but power-flow problems become nonlinear when bus injections are specified as powers rather than currents.
Frequency-dependent measurements
Measuring admittance over frequency helps distinguish conductive, capacitive, and inductive behavior. Applications include component characterization, dielectric testing, and electrochemical measurements.
For an ideal parallel-plate sample with area , thickness , conductivity , and real permittivity , a simple model gives
More complex materials may require frequency-dependent conductivity, complex permittivity, or additional elements representing interfaces and distributed processes.
Multiport networks
A network with several ports can be described by admittance parameters:
With currents defined as entering the ports, is the current response at port per unit voltage at port , while all other port voltages are held at zero. These short-circuit admittance parameters are used in amplifier, filter, and network modeling.
Measurement and limitations
Admittance can be obtained by measuring voltage, current, and their phase difference with an impedance analyzer, an LCR meter, or a suitable bridge circuit. Practical measurements must account for lead resistance and inductance, stray capacitance, fixture effects, and instrument calibration. Near an open circuit, very small currents make leakage and parasitic capacitance especially important.
A single frequency-dependent admittance most directly describes a linear, time-invariant circuit in steady state. For nonlinear devices, a small-signal admittance can be defined about a specified bias point, but it need not describe large-signal behavior. It may also depend on temperature, signal amplitude, and operating conditions.
At high frequencies, propagation delays and distributed effects can invalidate a lumped-element description. A terminal admittance can still be defined, but it may vary strongly with frequency and depend on the chosen reference plane. In multiport measurements, the input admittance also depends on how the other ports are terminated.