A lysimeter is an instrument or experimental installation that isolates a defined volume of soil so that water entering, leaving, or being stored within it can be measured. It is used to investigate evapotranspiration, drainage, and the movement of dissolved substances through soil. A typical field lysimeter contains a soil column, often with vegetation, exposed to local weather and equipped to collect drainage water. Weighing lysimeters additionally measure changes in the mass of the soil–plant system. The term is also applied to soil-water sampling devices, although these do not necessarily measure the complete water balance.
Principle and water balance
Lysimeters make selected components of the water cycle measurable within a physically defined experimental system. Their walls normally prevent lateral exchange with surrounding soil, while the upper surface remains exposed to rainfall, irrigation, evaporation, and plant growth. The lower boundary allows drainage to be collected or controlled.
For a lysimeter with no lateral water exchange, a water balance over a specified period can be written as
where:
- is the change in water stored in the system;
- is precipitation;
- is irrigation;
- is upward water input through the lower boundary;
- is evapotranspiration;
- is downward drainage;
- is surface runoff leaving the system.
All quantities must refer to the same area and time interval. They are commonly expressed as equivalent water depths, such as millimetres. If all other terms are measured adequately, evapotranspiration can be calculated as the residual:
This expression follows conservation of mass. Its usefulness depends on accounting for every significant water pathway. Leakage, unmeasured overflow, or incorrect estimates of storage change can otherwise be mistaken for evapotranspiration.
Evapotranspiration combines evaporation from soil and wet surfaces with transpiration through plants. A conventional lysimeter measures their combined effect; separating them requires additional measurements or experimental arrangements.
Main types
Weighing lysimeters
A weighing lysimeter places the soil container on a weighing mechanism, commonly electronic load cells. Changes in measured mass reveal gains or losses of water after allowing for drainage, rainfall, irrigation, and other material transfers.
For a mass change attributable solely to water, the corresponding change in water depth is
where is the mass change, is water density, and is the exposed surface area. One kilogram of water distributed over one square metre corresponds approximately to one millimetre of water depth.
High-resolution systems can resolve short-term changes and support subdaily estimates of evapotranspiration. However, rainfall and evapotranspiration may occur simultaneously, so mass change alone cannot always distinguish their individual contributions. Whether the drainage receiver is included on the weighing platform also affects how mass changes must be interpreted.
Non-weighing drainage lysimeters
A non-weighing lysimeter collects drainage without continuously weighing the soil column. Evapotranspiration can still be estimated from the water balance if precipitation, irrigation, runoff, and storage changes are measured independently.
These installations are often simpler than weighing systems and are useful for measuring drainage volumes and solute losses. Their water-balance estimates generally depend more heavily on soil-water measurements and may be less reliable over short intervals, when changes in storage are difficult to quantify.
Monolithic and repacked lysimeters
Lysimeters can also be classified by how their soil is installed:
- Monolithic lysimeters contain an intact soil block extracted with as little disturbance as practicable. They aim to preserve soil horizons, roots, cracks, and connected pores.
- Repacked lysimeters contain excavated soil placed into a container, sometimes in layers corresponding to the original profile. They allow greater control over composition and treatment but alter natural structure.
These categories are independent of weighing: either type may be installed on a weighing system.
Suction lysimeters and soil-water samplers
A suction lysimeter usually consists of a porous cup installed in soil and connected to a sampling vessel. Applied suction draws soil water through the cup for chemical analysis.
Unlike an isolated soil-column lysimeter, a suction sampler does not ordinarily measure the total volume of water moving through the soil. It provides samples from which concentrations can be determined, but calculating a solute flux requires a separate estimate of water flux. Sampling also depends on soil wetness, applied suction, contact between the cup and soil, and the chemical properties of the sampling material.
Construction and boundary conditions
Field lysimeters are commonly installed with their surfaces level with the surrounding ground. The vegetation and management inside the instrument should resemble those outside it when the objective is to represent field conditions. Subsurface access may accommodate weighing equipment, drainage collectors, pumps, and sensors.
Container dimensions influence what can be studied. Small units are comparatively easy to handle but may restrict roots and inadequately represent spatial variability. Larger units can include deeper profiles and more vegetation, but become heavier, more expensive, and harder to extract or replicate.
The lower boundary is particularly important because water movement depends on both gravity and gradients in soil-water potential.
- Passive drainage systems allow water to leave through an outlet, filter, or drainage layer. The soil immediately above the outlet may need to become relatively wet before outflow occurs.
- Controlled-suction systems apply a specified suction at the base, sometimes adjusted using measurements in adjacent soil.
- Water-table systems maintain or vary a saturated level to study interactions with shallow groundwater and upward water movement.
No lower-boundary arrangement reproduces every natural setting. For example, a shallow container with passive drainage can retain more water near its base than the corresponding depth in a deep, freely draining field profile.
Measurements and interpretation
Besides weighing and drainage collection, lysimeter installations may measure soil water content, soil-water pressure, temperature, precipitation, and plant growth. Chemical analyses of drainage water reveal the movement of nutrients, salts, pesticides, and other substances.
For drainage divided into sampling intervals, the exported mass of a dissolved substance can be estimated as
where is the representative concentration and is the drainage volume for interval . Dividing by surface area gives an areal load.
Concentrations must represent the associated drainage volume. An occasional grab sample may miss a brief, high-concentration pulse and therefore give a poor estimate of total export. Flow-proportional sampling or sufficiently frequent collection can improve the estimate.
The amount of a substance leaving the soil is not necessarily equal to the amount originally applied. Plant uptake, chemical transformation, microbial activity, and adsorption to soil particles can retain or alter it. Water may also move rapidly through cracks and large pores, bypassing much of the soil matrix.
Applications
Crop water use
Lysimeters provide experimental measurements of crop evapotranspiration and are used to evaluate irrigation practices. Under defined crop and water-supply conditions, their measurements can support the derivation of crop coefficients used with reference evapotranspiration.
Representativeness requires appropriate vegetation, soil moisture, and surrounding land cover. An irrigated lysimeter surrounded by dry ground may receive additional heat from its surroundings and show greater evapotranspiration than a comparable crop within an extensive irrigated field.
Leaching and environmental transport
Drainage lysimeters are used to investigate leaching of fertilizers, salts, pesticides, and contaminants. Because both drainage volume and chemical composition can be measured, they connect observed concentrations with transported quantities.
Experiments can compare soils, application rates, management practices, and rainfall regimes. Results nevertheless describe transport through the investigated soil depth and boundary conditions; they do not by themselves establish the eventual concentration in an underlying aquifer.
Hydrological research
Lysimeter observations help test soil-water and solute-transport models. They can also serve as comparison measurements for evapotranspiration estimates derived from weather data, remote sensing, or atmospheric flux methods.
Differences in spatial scale matter: a lysimeter measures a bounded soil volume, whereas other methods may represent an entire field or a variable upwind area.
Development
Early lysimeter experiments concentrated on collecting water that had passed through soil and determining the dissolved material it carried. Agricultural research expanded their use to nutrient losses, drainage, and crop water requirements.
Mechanical weighing systems, followed by electronic load cells and automated recording, made it possible to observe smaller mass changes more frequently. Modern installations may combine intact soil monoliths, controlled lower-boundary conditions, automated drainage sampling, and continuous environmental measurements.
Limitations and measurement quality
A lysimeter is a controlled representation of a soil–plant system, not an unaltered portion of the landscape. Important limitations include:
- Installation disturbance: extraction or repacking can change roots, pore networks, and soil structure.
- Wall effects: gaps may create preferential drainage paths, while walls prevent natural lateral exchange.
- Restricted rooting: container depth and width can alter root development and access to water.
- Boundary mismatch: drainage conditions at the base may differ from those in the surrounding profile.
- Limited spatial coverage: a small number of units may not represent heterogeneous soils or vegetation.
- Weighing disturbances: wind loading, thermal effects, mechanical contact, and instrument drift can affect recorded mass.
- Non-water mass changes: crop growth, harvesting, litter removal, fertilizer additions, and maintenance can introduce mass changes unrelated to water exchange.
Reliable interpretation therefore depends on calibration, leak testing, documentation of management events, and explicit treatment of measurement uncertainty. High weighing precision alone does not guarantee an equally accurate estimate of field-scale evapotranspiration or solute transport.