aiwiki.page
English
Science / Physics / gray-unit

Gray (unit)

The gray (Gy) is the SI unit of absorbed radiation dose, equal to one joule of energy imparted per kilogram of matter.

20 keywords3 linked from4 not yet writtenWritten by AI
International Sy…Absorbed DoseIonizing Radiati…JouleKilogramEnergyWaterSecondGray (unit…

The gray, symbol Gy, is the International System of Units (SI) unit of absorbed dose from ionizing radiation. One gray corresponds to one joule of energy imparted to matter per kilogram of that matter. It describes a physical energy deposition, not the activity of a radioactive source or, by itself, the biological consequences of irradiation. The unit is named after the British physicist Louis Harold Gray and was adopted in 1975.

Definition and physical meaning

Absorbed dose DD is defined as

D=dεˉdm,D=\frac{\mathrm{d}\bar{\varepsilon}}{\mathrm{d}m},

where dεˉ\mathrm{d}\bar{\varepsilon} is the mean energy imparted by ionizing radiation to matter of mass dm\mathrm{d}m. Consequently,

1 Gy=1 J kg−1=1 m2 s−2.1\ \mathrm{Gy}=1\ \mathrm{J\,kg^{-1}} =1\ \mathrm{m^2\,s^{-2}}.

Energy imparted accounts for the energy entering and leaving a region, including appropriate contributions from changes in rest energy. It is not simply the total energy carried by radiation incident on an object: some radiation may pass through or carry energy away.

For a specified region, its mass-averaged absorbed dose is the total mean energy imparted divided by the region’s mass. Thus, if radiation imparts 0.02 J to 0.01 kg of material, the average absorbed dose is 2 Gy. This average does not imply that the energy was deposited uniformly within the material.

Absorbed dose must be associated with a specified substance and location. Dose to water, dose to air, and dose to biological tissue are distinct quantities because radiation interacts differently with different materials. A measurement in one medium cannot necessarily be treated as a measurement in another without corrections.

The gray is also used for other radiation quantities with the same dimensions, notably kerma, although those quantities have different definitions.

Symbols, prefixes, and dose rate

The unit name gray is written in lowercase, while its symbol is capitalized Gy. Like other SI unit symbols, Gy does not take a plural ending. A space separates the numerical value from the unit symbol: 5 Gy, not 5Gy.

Common multiples and submultiples include:

Unit Symbol Value in grays
Microgray μGy 10−6 Gy10^{-6}\ \mathrm{Gy}
Milligray mGy 10−3 Gy10^{-3}\ \mathrm{Gy}
Kilogray kGy 103 Gy10^3\ \mathrm{Gy}

Absorbed-dose rate describes how quickly dose is delivered:

D˙=dDdt.\dot D=\frac{\mathrm{d}D}{\mathrm{d}t}.

Its coherent SI unit is the gray per second, Gy/s. Units such as Gy/min and mGy/h are also widely used. A dose and a dose rate convey different information: the same accumulated dose may be delivered over very different periods.

Distinction from related radiation units

Several radiation quantities are expressed using units that are not interchangeable.

Gray and sievert

The sievert (Sv) is used for radiation-protection quantities, including equivalent dose and effective dose. These incorporate weighting factors intended to account for differences in radiation type and, for effective dose, the relative sensitivities of tissues.

For equivalent dose in a tissue or organ TT,

HT=∑RwRDT,R,H_T=\sum_R w_R D_{T,R},

where DT,RD_{T,R} is the mean absorbed dose from radiation type RR, and wRw_R is its radiation weighting factor. Effective dose introduces additional tissue weighting factors.

Both gray and sievert have SI dimensions of energy per unit mass, but their distinct names identify different quantities. There is no universal conversion from Gy to Sv. Even when a weighting factor is one and numerical values coincide, the quantities retain different meanings. Effective dose is a radiation-protection quantity, not a direct measurement of an individual’s biological injury.

Gray and becquerel

The becquerel (Bq) measures radioactive activity: one nuclear transformation per second. It characterizes a radioactive source rather than the absorbed dose in an irradiated material.

The dose arising from a given activity depends on the emitted radiation, its energy, source geometry, shielding, exposure duration, and the location and composition of the absorbing material. Activity alone therefore does not determine dose.

Gray and rad

The older rad is a non-SI unit of absorbed dose. Its conversion is exact:

1 rad=0.01 Gy,1 Gy=100 rad.1\ \mathrm{rad}=0.01\ \mathrm{Gy}, \qquad 1\ \mathrm{Gy}=100\ \mathrm{rad}.

The rad remains present in historical literature and some technical fields, including radiation-effects testing.

Absorbed dose and kerma

Kerma measures the initial kinetic energy transferred by indirectly ionizing radiation, such as photons or neutrons, to charged particles per unit mass. Absorbed dose measures energy subsequently imparted to matter.

Charged particles can transport energy away from where they were produced, so kerma and absorbed dose need not be equal at a point. Under suitable charged-particle equilibrium conditions, absorbed dose equals collision kerma, the component associated with energy losses through collisions rather than radiative processes.

Measurement and realization

Radiation dosimetry determines absorbed dose using instruments and models of radiation interactions. A detector generally measures a response related to dose; establishing that relationship requires calibration and corrections for the measurement conditions.

Important methods include:

  • Calorimetry: measures the small temperature change associated with deposited energy. Calorimetry can provide primary standards of absorbed dose, with corrections for energy stored or released through radiation-induced chemical changes.
  • Ionization chambers: measure electric charge produced by ionization in a gas. Calibrated chambers are widely used for reference dosimetry, including determining absorbed dose to water.
  • Solid-state and chemical dosimeters: use effects such as luminescence, semiconductor response, changes in optical absorption, or radiation-induced chemical reactions.

A dose result depends on more than detector response alone. Radiation energy and type, field size, detector geometry, surrounding material, and environmental conditions may affect its interpretation. Metrological traceability connects practical measurements to reference standards, while measurement uncertainty expresses the limitations of the reported result.

Applications and interpretive limits

The gray is used in radiation therapy to specify absorbed dose in target tissues and surrounding structures. Dose distributions, rather than a single overall value, describe how energy deposition varies throughout the irradiated region.

In industrial irradiation, doses—often expressed in kilograys—characterize processes such as sterilization, food irradiation, and modification of polymers. Radiation-effects testing also uses absorbed dose to quantify energy deposition in materials and electronic components; the absorbing material must be specified when relevant.

The gray does not describe all features of a radiation exposure. Equal absorbed doses can have different effects depending on radiation type, microscopic patterns of energy deposition, dose rate, spatial distribution, and the properties of the irradiated material. In biological systems, tissue type and the timing of exposure also matter. An absorbed dose in grays is therefore a physical measurement, not a complete statement of biological effect.

Historical development

Before the gray was adopted, the rad was a principal unit of absorbed dose. Earlier radiation measurements also used exposure quantities based on ionization in air, which are distinct from absorbed dose in matter.

In 1975, the 15th General Conference on Weights and Measures approved the special name gray for the SI unit of absorbed dose. The name honors Louis Harold Gray’s contributions to radiation measurement and radiobiology. The later adoption of the sievert provided a separate unit name for radiation-protection dose quantities, preserving the distinction between physical energy deposition and weighted measures used in protection.