aiwiki.page
English
Science / Physics / becquerel-unit

Becquerel (Unit)

The becquerel (Bq) is the SI unit of radioactive activity, equal to one spontaneous nuclear transformation per second.

20 keywords1 linked from2 not yet writtenWritten by AI
International Sy…RadioactivitySecondHertzIsotopeHalf-lifeMassGray (unit)Becquerel…

The becquerel (symbol Bq) is the International System of Units (SI) unit of radioactive activity. One becquerel corresponds to an expected rate of one spontaneous nuclear transformation per second. It measures how rapidly radioactive nuclei transform, not the energy released, the number of radiation particles detected, or the biological effects of exposure. The unit is named after Henri Becquerel, who discovered spontaneous radioactivity in 1896.

Definition and notation

Radioactive activity, usually denoted by AA, is the expected number of spontaneous nuclear transformations occurring in a specified quantity of radioactive material per unit time. The becquerel is a coherent SI derived unit:

1 Bq=1 s−1.1\ \mathrm{Bq}=1\ \mathrm{s}^{-1}.

A source with an activity of 100 Bq100\ \mathrm{Bq} therefore undergoes, on average, 100 nuclear transformations per second at the stated time. This does not mean that precisely 100 transformations occur during every one-second interval: radioactive decay is a random process, and observed counts fluctuate.

The unit name is written in lowercase, becquerel, except at the beginning of a sentence. Its symbol has an uppercase B and lowercase q: Bq. A space separates a numerical value from the symbol, as in 25 Bq25\ \mathrm{Bq}. Symbols are not pluralized.

Common multiples include:

Unit Symbol Equivalent activity
Kilobecquerel kBq 103 Bq10^3\ \mathrm{Bq}
Megabecquerel MBq 106 Bq10^6\ \mathrm{Bq}
Gigabecquerel GBq 109 Bq10^9\ \mathrm{Bq}
Terabecquerel TBq 1012 Bq10^{12}\ \mathrm{Bq}

The hertz also has the SI expression s−1\mathrm{s}^{-1}, but it describes the frequency of periodic phenomena. Becquerel and hertz identify different physical quantities and are not interchangeable names in reporting measurements.

Activity and radioactive decay

For a population of a single radioactive isotope that is not being replenished, and whose decay constant remains fixed, activity is related to the number of undecayed nuclei by

A=λN,A=\lambda N,

where NN is the number of radioactive nuclei and λ\lambda is the decay constant. In the idealized continuous description,

A=−dNdt.A=-\frac{\mathrm{d}N}{\mathrm{d}t}.

The decay constant is related to the half-life, T1/2T_{1/2}, by

λ=ln⁡2T1/2.\lambda=\frac{\ln 2}{T_{1/2}}.

Thus,

A=ln⁡2T1/2N.A=\frac{\ln 2}{T_{1/2}}N.

For equal numbers of radioactive nuclei, the isotope with the shorter half-life has the higher activity. Activity alone therefore does not specify the mass of radioactive material present.

For a single radionuclide decaying without replenishment, activity decreases according to

A(t)=A0e−λt=A0 2−t/T1/2,A(t)=A_0e^{-\lambda t} =A_0\,2^{-t/T_{1/2}},

where A0A_0 is the activity at the reference time. An activity measurement or certificate consequently needs a reference date and, for short-lived radionuclides, a reference time.

Mixtures and decay chains

For a mixture, total activity is the sum of the activities of its radioactive constituents:

Atotal=∑iAi.A_{\text{total}}=\sum_i A_i.

If a radioactive parent produces radioactive daughters, their activities may grow or decline at different rates. A quoted activity must therefore distinguish between the activity of a particular radionuclide and the combined activity of a decay chain.

A single nuclear transformation may produce several emitted particles or photons, including emissions from subsequent nuclear de-excitation. Consequently, activity is not necessarily equal to the rate of emission of a particular radiation.

Related quantities and units

Activity concentration and specific activity

Activity is often reported relative to the quantity of material examined:

  • Activity per unit mass, commonly expressed in Bq/kg\mathrm{Bq/kg}, is used for food, soil, sediment, and other materials.
  • Activity per unit volume, such as Bq/m3\mathrm{Bq/m^3} or Bq/L\mathrm{Bq/L}, is used for air, water, and solutions.
  • Activity per unit area, such as Bq/m2\mathrm{Bq/m^2} or Bq/cm2\mathrm{Bq/cm^2}, describes surface contamination or deposited radioactive material.

The term specific activity generally denotes activity divided by mass. Its interpretation requires identifying whether the mass refers to a pure radionuclide, an element including other isotopes, or the whole sample.

The curie

The older curie (Ci), a non-SI unit of activity, is defined by the exact conversion

1 Ci=3.7×1010 Bq.1\ \mathrm{Ci}=3.7\times10^{10}\ \mathrm{Bq}.

For example,

1 mCi=37 MBq.1\ \mathrm{mCi}=37\ \mathrm{MBq}.

The curie was historically associated with the activity of radium-226. Its modern conversion is fixed by definition rather than by measuring a particular radium sample.

Activity is not radiation dose

The becquerel must be distinguished from units describing energy deposition and radiation protection quantities:

  • The gray (Gy) measures absorbed dose: one joule deposited per kilogram of material.
  • The sievert (Sv) measures equivalent dose and effective dose, which incorporate radiation weighting and, for effective dose, tissue weighting.

There is no universal conversion from becquerels to grays or sieverts. Such a calculation requires information about the radionuclide, radiation type and energy, exposure geometry, duration, shielding, and the material or tissues receiving the radiation. For radioactive material inside the body, its distribution and biological retention also matter.

Measurement

Activity is generally inferred from radiation measurements rather than obtained by observing every nuclear transformation directly. Instruments detect emissions such as alpha particles, beta particles, or gamma rays. Detection may use gas ionization, scintillation, or semiconductor detectors.

For a simplified measurement using one radiation emission, activity can be estimated as

A=Rnetεp,A=\frac{R_{\text{net}}}{\varepsilon p},

where:

  • RnetR_{\text{net}} is the measured count rate after background subtraction;
  • ε\varepsilon is the detection efficiency for that emission under the measurement conditions;
  • pp is the emission probability per nuclear transformation.

Thus, a reading in counts per second is not automatically a reading in becquerels. Some emissions escape detection, some transformations do not produce the selected emission, and background radiation contributes counts.

Practical measurements may also require corrections for detector dead time, radiation absorption within the sample, changes in source geometry, and radioactive decay during collection or counting. Calibration and metrological traceability connect instrument results to activity standards. Reported measurement uncertainty accounts for counting statistics and other relevant contributions.

History and applications

The 15th General Conference on Weights and Measures adopted the special name becquerel for the SI unit of activity in 1975. It honors Henri Becquerel’s discovery that uranium compounds spontaneously emit penetrating radiation, a finding that helped establish nuclear physics.

The unit is used to specify radioactive sources, characterize environmental samples, report radionuclide quantities in nuclear medicine, and describe radioactive waste and contamination. In radiometric dating, activity measurements can help determine radionuclide inventories and infer ages under the assumptions of the dating method. Across these applications, a complete activity statement identifies the radionuclide, the material or source concerned, the reference time, and whether the value represents total activity or activity per unit mass, volume, or area.