Absorbed dose is a physical quantity that describes the mean energy imparted by ionizing radiation to matter per unit mass. It applies to any irradiated material, including biological tissue, water, air, and solid-state devices. Its SI unit is the gray (Gy), equal to one joule per kilogram. Absorbed dose measures energy deposition, not radioactive activity or biological harm; interpreting it requires information about the material, radiation field, and spatial and temporal distribution of irradiation.
Definition and units
The absorbed dose is defined as
where is the mean energy imparted by ionizing radiation to matter of mass . Energy imparted accounts for radiation energy entering and leaving a region, together with relevant changes in rest energy within it.
The mean is important because radiation interactions occur as discrete, random events. At microscopic scales, the energy imparted to otherwise identical volumes can fluctuate substantially. Absorbed dose is a non-stochastic quantity obtained from the expectation of these events, rather than the outcome of a single particle interaction.
The unit relation is
using the joule and kilogram. Common submultiples include the milligray, , and microgray, .
The older unit rad is related to the gray by
For example, a mean energy deposition of in corresponds to a mean absorbed dose of , or .
For a finite region, the mass-averaged dose is
An average can conceal large variations within the region. A whole-organ average, for example, does not specify the dose at every location in that organ.
Physical mechanisms
Radiation deposits energy through interactions with atoms and molecules. Charged particles, such as electrons and protons, lose energy through excitation and ionization, producing secondary particles along their paths.
Uncharged radiation generally deposits energy through the charged particles it sets in motion:
- Photons, including X-rays and gamma rays, transfer energy to electrons through processes such as photoelectric absorption, Compton scattering, and pair production.
- Neutrons transfer energy through nuclear interactions, producing recoil nuclei and other secondary particles.
Energy transferred in one location may be deposited elsewhere. Consequently, the dose at a point depends not only on the incident radiation but also on the transport of secondary particles, the surrounding material, and the irradiation geometry.
Absorbed dose must therefore be associated with a specified material. “Dose to water” and “dose to tissue” are not automatically interchangeable, even for the same incident radiation field.
Dose rate and dose distribution
The absorbed-dose rate is
usually expressed in grays per second or a practical equivalent such as milligrays per hour. The accumulated dose over a time interval is
Dose rate distinguishes a dose delivered rapidly from the same total dose delivered over a longer interval. Pulsed irradiation can require additional quantities, including dose per pulse and pulse repetition frequency.
A spatial dose distribution describes how dose varies throughout an object. In external radiation beams, this distribution depends on beam energy, field size, depth, material composition, and geometry. Near surfaces and interfaces, the transport of secondary charged particles can produce steep dose gradients. A single dose value does not fully characterize such a distribution.
Relationship to other radiation quantities
Several radiation quantities describe different stages or consequences of irradiation.
| Quantity | What it describes | Common unit |
|---|---|---|
| Activity | Rate of nuclear transformations in a radioactive source | Becquerel (Bq) |
| Absorbed dose | Mean energy imparted per unit mass | Gray (Gy) |
| Kerma | Initial kinetic energy transferred to charged particles per unit mass by uncharged radiation | Gray (Gy) |
| Equivalent dose | Organ- or tissue-averaged absorbed dose weighted for radiation type | Sievert (Sv) |
| Effective dose | Tissue-weighted sum of equivalent doses | Sievert (Sv) |
Activity
Radioactive activity characterizes a source, not the dose received by a particular object. There is no universal conversion from becquerels to grays. The resulting dose depends on emission energies, radiation types, exposure duration, source geometry, shielding, and the fraction of emitted energy absorbed.
Kerma
Kerma describes energy transferred from uncharged radiation to secondary charged particles, whereas absorbed dose describes energy imparted locally to matter. These quantities can differ because charged particles transport energy away from their points of creation.
Under charged-particle equilibrium, absorbed dose equals collision kerma, the component associated with energy losses through collisions rather than radiative losses. Near interfaces, in small fields, or where particle ranges are large relative to the irradiated region, this equilibrium may not hold. Total kerma and absorbed dose should therefore not be treated as generally identical.
Equivalent and effective dose
Equivalent dose and effective dose are radiation-protection quantities that apply weighting factors to absorbed dose. Equivalent dose incorporates radiation weighting factors; effective dose additionally incorporates tissue weighting factors.
Although the gray and sievert both have the dimensions of joules per kilogram, they identify different quantities. The units are not interchangeable merely because their dimensions match. Effective dose is intended for radiation-protection purposes and is not a direct measure of an individual person’s biological response.
Measurement and calculation
Radiation dosimetry determines absorbed dose through measurement, calculation, or a combination of both. Most instruments do not directly measure the energy imparted to the final material of interest. Instead, their response is converted into dose using calibration coefficients and physical models.
Major methods include:
- Ionization chambers, which measure charge produced in a gas. Appropriate conversion and correction factors relate the chamber signal to dose in a specified medium.
- Calorimeters, which infer absorbed energy from a small temperature change. Calorimetry can provide a primary realization of absorbed dose, with corrections for effects such as energy stored in chemical changes rather than appearing immediately as heat.
- Solid-state and luminescent detectors, which use radiation-induced electrical signals or stored excitation.
- Radiochromic films and chemical dosimeters, which use measurable changes in optical or chemical properties.
Calibration and metrological traceability connect measurements to reference standards. Measurement uncertainty includes contributions from detector calibration, positioning, environmental corrections, radiation quality, and the conversion from detector response to dose in the target material.
Computational methods, including Monte Carlo particle transport, calculate dose by modelling radiation interactions and secondary-particle transport. Their accuracy depends on the physical models, input radiation field, material descriptions, geometry, and experimental validation.
Applications and interpretation
Absorbed dose is central to radiotherapy, where the spatial distribution of dose is calculated, delivered, and verified. It is also used in diagnostic-radiation dosimetry, radiation-processing control, sterilization, materials testing, and studies of radiation effects on electronics.
The same absorbed dose does not necessarily produce the same biological effect. Radiation type, microscopic energy-deposition pattern, dose rate, fractionation, oxygen conditions, and the biological system all influence the response. Energy deposition can damage molecules directly or initiate chemical reactions that affect structures such as DNA.
Likewise, equal doses in different non-biological materials need not cause equal changes in performance or structure. Absorbed dose specifies an energy-per-mass quantity; predicting chemical, biological, or engineering consequences requires additional information.
Historical development
Early radiation measurements often emphasized ionization in air, including the exposure quantity historically expressed in roentgens. Such measurements did not by themselves specify energy absorbed in every irradiated material.
The rad became widely used as an absorbed-dose unit during the twentieth century. In 1975, the General Conference on Weights and Measures adopted the special SI name gray, honoring the radiation physicist Louis Harold Gray. The gray established a unit name specifically associated with absorbed dose and related energy-per-mass radiation quantities.