Étendue is a quantity in optics that measures the combined area and angular spread occupied by a bundle of light rays, with a factor accounting for the refractive index of the medium. In ideal, lossless geometrical optics, étendue is conserved: reducing a beam’s cross-sectional area requires a corresponding increase in its angular spread. This conservation law sets fundamental limits on light collection, image brightness, solar concentration, and coupling between optical instruments.
Definition
For rays crossing a small surface element, the differential étendue is
where:
- is the refractive index of the medium;
- is the surface area element;
- is the angle between a ray’s direction and the surface normal;
- is an element of solid angle around that direction.
For a complete ray bundle,
The angular domain can vary with position on the surface. This matters because many beams have correlations between ray position and direction: not every direction occurs at every point.
The cosine factor accounts for projected area. A surface viewed obliquely presents a smaller collecting area than the same surface viewed face-on.
Étendue is normally expressed in square metres steradian, . In the International System of Units, the steradian is dimensionless, so étendue has the physical dimension of area; retaining “sr” makes its angular meaning explicit.
Conventions
Some authors define geometrical extent without the refractive-index factor:
In a uniform medium, . Under this convention, , rather than alone, is conserved when rays pass between media. The word throughput is also used for étendue, although in other contexts it means transmitted power or transmission efficiency. Definitions therefore need to be checked when comparing formulas.
Common geometries
Uniform circular cone
Consider an area in a uniform medium, with every point accepting all directions in a circular cone of half-angle about the surface normal. Its étendue is
Using the numerical aperture, ,
This expression applies only when the stated area and angular cone are fully accepted. An obscured, vignetted, or position-dependent acceptance generally requires the full integral.
For a narrow cone, and its solid angle is approximately . Thus,
The familiar area–solid-angle product is therefore a small-angle approximation unless is explicitly understood as a projected solid angle.
Hemispherical emission
A surface emitting into all directions of one hemisphere has
The factor is , not , because étendue includes the cosine projection. A Lambertian surface, whose radiance is direction-independent, is an important example of emission occupying this hemispherical domain.
Exchange between two surfaces
For two mutually visible surface elements separated by distance in a uniform medium,
Here and are measured from the respective surface normals. The symmetry between the surfaces underlies reciprocity relations used in radiative transfer.
Conservation and optical invariants
In lossless geometrical optics, propagation through free space, ideal reflection, and refraction preserves the étendue of a ray bundle. Focusing changes the balance between beam area and angular spread, but not their combined optical extent.
For example, an imaging system that reduces a source’s image area must increase the range of ray directions at the image if it transmits the complete bundle. A small image does not by itself imply that all the original light can enter a narrow-angle detector or optical fibre.
The factor accounts for changes in angular spread across refracting interfaces. Rays entering a higher-index medium can occupy a narrower cone without violating conservation.
Phase-space interpretation
A ray crossing a plane can be described by two transverse position coordinates and two direction-related coordinates. Étendue measures a volume in this four-dimensional optical phase space.
For a plane normal to the -axis, define optical momentum coordinates
where and are transverse components of the ray’s unit direction vector. For forward-going rays,
Ideal optical propagation preserves this phase-space volume, an optical counterpart of Liouville’s theorem in Hamiltonian mechanics. This makes étendue more general than a simple product of a beam diameter and a divergence angle.
The Lagrange optical invariant is closely related. In a centered, paraxial imaging system, a combination of the heights and angles of two rays remains constant. It describes a meridional constraint, whereas étendue describes the full spatial and angular extent of a bundle; the two are related but are not interchangeable quantities.
Losses and scattering
Conservation applies to an identified bundle of rays under the stated ideal conditions. An aperture can remove rays and thereby reduce both transmitted power and transmitted étendue. It does not compress the full input bundle into a smaller optical phase-space volume.
Scattering and diffusers can spread radiation over additional directions, increasing its effective occupied étendue and generally reducing its radiance. Absorption can reduce power without changing the geometrical domain occupied by the surviving rays. These distinctions are important when interpreting the shorthand statement that “étendue cannot decrease.”
Radiance and the brightness theorem
Radiance is radiant power per unit projected area per unit solid angle:
where is radiant flux. Consequently,
For uniform radiance in a uniform medium,
Conservation of power and étendue implies conservation of reduced radiance, , along a ray in a transparent, lossless optical system. At a refracting interface, radiance itself can change with ; reflection and absorption losses must be treated separately.
This result is commonly called the brightness theorem. Passive optical rearrangement cannot increase reduced radiance above that supplied by the source. A lens can increase irradiance—the power incident per unit receiving area—by gathering light from a larger area and delivering it through a wider cone of directions. That does not increase radiance.
The theorem concerns passive transport under geometrical-optics assumptions. Optical amplification and the generation or wavelength conversion of light require additional analysis rather than direct application of this statement.
Limits on optical concentration
Étendue conservation places a maximum on how much an extended source can be concentrated while retaining all accepted rays.
For an ideal three-dimensional concentrator accepting a complete circular cone of half-angle , let be its entrance area and its receiving area. If the input medium has index ,
The largest output étendue available over the receiving hemisphere is
Transmitting the whole accepted bundle therefore requires
In the same medium on both sides, the maximum area concentration is . A source with a larger angular extent has a lower maximum concentration.
This limit is central to solar concentrators: the Sun has a finite apparent angular size, so even ideal optics cannot focus all direct sunlight onto an arbitrarily small receiver. Practical concentration is lower because of imperfect surfaces, alignment errors, finite acceptance margins, and transmission losses. Two-dimensional, line-focusing concentrators obey a different concentration relation.
Applications
Imaging and astronomy
In telescopes, collecting area determines how much light enters, while field of view determines the angular region observed. Their product is often used as a survey-speed indicator and called the instrument’s étendue. For small fields in air it approximates the accepted geometrical étendue, although actual performance also depends on transmission, image quality, detector properties, and observing conditions.
In microscopy, the area imaged and the accepted numerical aperture jointly determine the collected optical extent. Magnification trades image area against angular spread rather than creating additional brightness.
Spectroscopy
In spectroscopy, entrance slits, pupils, dispersing elements, and detectors constrain the accepted ray bundle. Enlarging an entrance slit can admit more light but may degrade spectral resolution. Étendue provides a way to distinguish collection capacity from optical transmission efficiency and resolving power.
Fibre coupling and illumination
For a multimode optical fibre with core area and approximately uniform acceptance cone, its geometrical acceptance is often estimated as
A source occupying a larger étendue cannot be coupled completely into that acceptance by ideal passive optics alone.
The same constraint governs projectors and illumination systems. Efficient design requires matching the source’s spatial and angular distribution to the acceptance of the modulator, relay optics, and target. Matching a spot size without matching its angular distribution can still produce substantial losses.
Diffraction and limits of the ray description
Geometrical étendue is most directly useful when optical dimensions are large compared with the wavelength. Near the diffraction limit, wave structure and spatial coherence become essential.
For a single transverse spatial mode, the characteristic étendue is of order
where is the vacuum wavelength. Precise numerical factors depend on definitions of beam area, angular width, mode counting, and polarization. A multimode field can occupy many such spatial-mode cells.
A Gaussian beam illustrates the associated trade-off: reducing its waist increases its far-field divergence. Its intensity distribution has no sharp boundary, however, so assigning a finite geometrical étendue requires a specified beam-width or enclosed-power convention.
Étendue alone does not specify an optical field’s coherence, spectrum, polarization, or wavefront quality. Fields with similar area–angle products can therefore differ substantially in their diffraction-limited coupling and imaging performance.