Coercivity is a measure of a magnetic material’s resistance to reversal of its magnetization. It is usually determined by first magnetizing a specimen to saturation and then applying a magnetic field in the opposite direction. The magnitude of the reverse field at which either the magnetization or the magnetic flux density becomes zero is reported as a coercive field. These two criteria give different quantities, distinguished as intrinsic and normal coercivity. Coercivity is central to the distinction between magnetically hard materials, used to retain magnetization, and magnetically soft materials, designed to reverse magnetization readily.
Definition and hysteresis
In a ferromagnetic or ferrimagnetic material, magnetization generally depends on both the present magnetic field and the specimen’s previous magnetic history. Cycling the field produces a magnetic hysteresis loop rather than a single-valued, reversible relationship.
Starting from positive magnetic saturation, reducing the applied field to zero typically leaves a residual magnetization, called remanence. A reverse field is then required to bring the measured magnetization or flux density to zero. The corresponding field magnitude is the coercivity. Reversing the field farther eventually drives the specimen toward negative saturation.
Coercivity is conventionally reported as a positive magnitude, although the relevant crossing occurs at a negative field on the descending branch of a loop. For a symmetric loop, the ascending branch gives an equal and opposite crossing. Asymmetric or shifted loops may require reporting the two crossings separately.
A value measured after a field excursion insufficient to reach saturation belongs to a minor hysteresis loop and need not equal the major-loop coercivity. Consequently, the maximum magnetizing field is an important part of a measurement specification.
Normal and intrinsic coercivity
In the International System of Units, the magnetic flux density , magnetic field strength , and magnetization satisfy
where is the vacuum permeability. For a specified measurement direction, this relation can be applied to the corresponding components.
Two coercivities follow from the choice of quantity brought to zero:
- Normal coercivity, commonly written or , is the magnitude of the reverse field at which .
- Intrinsic coercivity, commonly written or , is the magnitude of the reverse field at which the magnetic polarization , and therefore , becomes zero.
The term magnetic polarization here denotes , not electric polarization or the polarization of light.
At the normal coercive point, zero flux density does not generally mean zero magnetization: the contributions of and cancel. Intrinsic coercivity more directly describes resistance to loss and reversal of the net magnetization. For a conventional demagnetization curve, intrinsic coercivity is at least as large as normal coercivity.
Despite the historical name coercive force, coercivity is a field strength, not a mechanical force. Its SI unit is the ampere per metre, usually expressed as A/m or kA/m. The older unit oersted remains common in magnetic-material specifications:
Some publications report in tesla. This is a field-strength quantity multiplied by , and should not be confused with the specimen’s flux density .
Microscopic origins
Coercivity arises because reversing magnetization requires overcoming barriers in a material’s magnetic energy landscape. These barriers depend on crystal structure, specimen shape, defects, interfaces, and interactions between magnetic regions.
Domain-wall motion
Many bulk magnetic materials contain magnetic domains: regions in which the magnetization is approximately aligned. Applied fields can change the relative sizes of these regions by moving their boundaries, called domain walls.
Defects, grain boundaries, inclusions, and local variations in magnetic properties can impede domain-wall motion. A reverse field must provide sufficient driving force to overcome this pinning. Alternatively, reversal may be limited by the formation of new reversed domains rather than by the movement of existing walls. Nucleation and pinning often act together, so a measured coercivity does not by itself identify a unique reversal mechanism.
Rotation and magnetic anisotropy
In sufficiently small particles, a domain wall may be energetically unfavorable. Magnetization can instead reverse through rotation, curling, or other nonuniform configurations.
Magnetic anisotropy makes some magnetization directions energetically preferable to others. Magnetocrystalline anisotropy originates from the coupling of magnetic moments to the crystal lattice; shape anisotropy results from the magnetostatic field associated with specimen geometry.
An ideal model of a noninteracting, uniformly magnetized particle with uniaxial anisotropy gives an anisotropy field
where is the anisotropy energy density and is the saturation magnetization. In the ideal coherent-rotation case, with the field along the easy axis and thermal activation neglected, the switching field equals . Real materials often reverse at substantially smaller fields because reversal begins at defects, interfaces, or locally unfavorable configurations.
Grain size and thermal activation
The relationship between grain size and coercivity is not universally monotonic. Reducing the size of multidomain particles can inhibit domain-wall processes and increase coercivity. At still smaller sizes, thermal fluctuations may enable spontaneous reversal on the measurement timescale, producing superparamagnetic behavior and very low measured coercivity.
A simplified description of thermally activated reversal is
where is the characteristic reversal time, an attempt timescale, an energy barrier, the Boltzmann constant, and the absolute temperature. An applied reverse field generally lowers the relevant barrier. Coercivity therefore depends on observation time and field-sweep rate as well as material structure.
Measurement and reporting
Coercivity is obtained from a measured hysteresis loop. Common instruments include vibrating-sample magnetometers, alternating-gradient magnetometers, superconducting quantum interference device magnetometers, and hysteresisgraph systems. Measurements based on the magneto-optical Kerr effect are also used, particularly for thin films and spatially resolved studies.
The distinction between applied and internal field is important. A magnetized specimen generates a demagnetizing field that depends on its shape and magnetization distribution. For a uniformly magnetized ellipsoid along a principal axis,
where is the dimensionless demagnetizing factor in the SI convention. More complicated geometries generally have nonuniform internal fields and cannot always be described exactly by one demagnetizing factor.
Reliable comparisons require specification of:
- Whether the reported value is normal or intrinsic coercivity.
- Measurement temperature and field orientation.
- Maximum applied field and magnetic preparation history.
- Field-sweep rate or measurement timescale.
- Specimen geometry and any demagnetizing correction.
- Whether the result comes from a major loop or a minor loop.
For thin films, coercivity may differ greatly between fields applied in the film plane and perpendicular to it. Instrument offsets, field calibration, background subtraction, and interpolation near the zero crossing contribute to measurement uncertainty.
Technological significance
Hard magnetic materials
Permanent magnets require sufficient coercivity to resist demagnetizing fields during operation. Examples include hard ferrites, samarium–cobalt magnets, and neodymium–iron–boron magnets.
High intrinsic coercivity helps preserve magnetization against reverse fields, including those produced by the magnet’s own shape or by surrounding components. Nevertheless, coercivity alone does not determine magnet performance. Remanence, the shape of the demagnetization curve, thermal stability, and the maximum energy product are also important.
The maximum energy product describes the largest magnitude of in the useful second-quadrant portion of the demagnetization curve. It is distinct from coercivity and cannot generally be inferred from it.
Soft magnetic materials
Soft magnetic materials are selected for low coercivity and readily reversible magnetization. Applications include transformer cores, inductors, electromagnets, and electric-machine cores. Common material families include electrical steels, soft ferrites, and amorphous or nanocrystalline magnetic alloys.
Low coercivity is associated with reduced hysteretic losses, but total core loss also includes eddy-current and other dynamic contributions. It therefore depends on operating frequency, waveform, electrical resistivity, and component geometry, not just the width of a quasistatic loop.
Magnetic recording
In magnetic recording, coercivity contributes to the stability of stored magnetic states. The medium must resist accidental reversal while remaining switchable by the writing system. Increasing anisotropy can improve thermal stability but also increase the field needed for writing, creating a trade-off among information density, retention, and writability.
Interpretation and limitations
Coercivity is not a universal constant fixed by chemical composition. Processing can change grain size, texture, residual stress, phase distribution, and grain-boundary chemistry, producing large differences between specimens of nominally the same material.
Nor is coercivity identical to hardness, magnetic strength, remanence, or magnetic permeability. A material can have a large saturation magnetization but low coercivity, or high coercivity without especially high remanence.
A zero net magnetization at the intrinsic coercive field also does not imply that every local magnetic moment has vanished. Oppositely magnetized regions may cancel macroscopically while remaining strongly magnetized locally. Coercivity characterizes a particular crossing of a measured reversal curve, rather than a complete description of the material’s magnetic state.