The Stokes parameters are four real quantities that describe the intensity and polarization state of a transverse beam of electromagnetic radiation. Usually written as , or equivalently , they characterize total intensity, two components of linear polarization, and circular polarization. Unlike a description based on a single pair of electric-field amplitudes, they accommodate fully polarized, partially polarized, and unpolarized radiation. They are widely used in optics, remote sensing, and astronomy because they can be determined from intensity measurements.
Historical background
George Gabriel Stokes introduced the four quantities in 1852 in his analysis of streams of polarized light. Their central advantage was the ability to describe mixtures of polarized and unpolarized radiation without following the rapid oscillations of the electromagnetic field.
The parameters later became the basis of the Stokes–Mueller formalism, which describes how optical systems transform polarization. Their statistical interpretation is closely related to the coherence matrix of classical optics and to the density matrix used in quantum theory.
Definition and conventions
Consider radiation propagating in a specified direction, with orthogonal transverse axes and . Let and be the complex amplitudes of the transverse electric field, using a time dependence . For a narrowband field, define
Here, the asterisk denotes complex conjugation, and angle brackets denote a suitable time or ensemble average. A common physical proportionality factor has been suppressed. With that factor included, the parameters have intensity units; in astronomical work they may instead be expressed as spectral radiance, flux density, or related quantities.
The parameters form the Stokes vector
Their meanings are:
| Parameter | Meaning |
|---|---|
| Total intensity | |
| Intensity difference between linear polarization along and along | |
| Intensity difference between linear polarization at and to | |
| Intensity difference between two orthogonal circular polarization states |
The sign of is not universal. Different disciplines and instruments use different definitions of circular handedness, viewing direction, and complex time dependence. Under the explicit convention above, a field proportional to has positive . Calling this state “right-circular” or “left-circular” requires a further convention.
The signs of and likewise depend on the orientation of the transverse reference axes. Stokes measurements must therefore specify both a coordinate frame and a circular-polarization convention.
Physical interpretation
Linear, circular, and elliptical polarization
For a fully polarized field written as
with , the parameters are
Thus measures the imbalance between orthogonal linear components, while and encode their relative phase as well as their amplitudes.
Some representative states are:
| Polarization state | Normalized Stokes vector |
|---|---|
| Linear along | |
| Linear along | |
| Linear at | |
| Linear at | |
| Circular with positive | |
| Circular with negative | |
| Unpolarized |
A general fully polarized state is elliptically polarized: at a fixed point, the electric-field vector traces an ellipse over an optical cycle.
Degree of polarization
Physically admissible Stokes parameters satisfy
For , the degree of polarization is
It distinguishes three cases:
- Fully polarized: .
- Partially polarized: .
- Unpolarized: , so .
The degree of linear polarization and the signed circular polarization fraction are
The magnitude is the unsigned degree of circular polarization.
An unpolarized beam does not lack an electric field. Rather, its averaged transverse correlations have no preferred polarization. The result depends on the temporal, spatial, and spectral averaging used in the measurement.
Every nonzero Stokes vector admits a unique decomposition, at the level of these second-order statistics, into an unpolarized contribution and a fully polarized contribution. Writing
gives
This mathematical decomposition does not identify a unique microscopic mixture of source fields.
Polarization ellipse and Poincaré sphere
For fully polarized radiation, let be the orientation of the polarization ellipse and its signed ellipticity angle. Then
The range includes linear polarization at and circular polarization at the endpoints. The minor-to-major axis ratio is . When the linear component is nonzero,
with orientation understood modulo . For circular polarization, the ellipse orientation is undefined. For partially polarized radiation, ellipse parameters describe its fully polarized component, not the entire fluctuating field.
The normalized parameters
provide coordinates in the Poincaré sphere representation. Fully polarized states lie on the unit sphere, partially polarized states lie inside it, and unpolarized radiation lies at its center. Linear polarization occupies the equator, while the circular states occupy opposite poles.
Opposite points on the surface represent orthogonal polarization states. The doubled angles reflect the fact that rotating a linear polarization direction through restores the same state.
Coherence matrix and Jones calculus
The transverse coherence, or coherency, matrix is
It is Hermitian and positive semidefinite. Its eigenvalues are
Their nonnegativity yields the physical constraint on the Stokes parameters.
A fully polarized nonzero state has a rank-one coherence matrix and can be represented by a Jones vector, a two-component complex field amplitude. An unpolarized state has , where is the two-dimensional identity matrix.
Jones vectors retain complex amplitude information but, individually, describe only fully polarized states. Stokes vectors and coherence matrices also describe statistical mixtures. They do not retain a common optical phase: multiplying both field components by the same phase factor leaves all four Stokes parameters unchanged. Consequently, Stokes vectors alone generally do not determine the interference of mutually coherent beams; their relative phase and cross-correlations are also required.
In quantum mechanics, has the mathematical form of a two-state density matrix. With the usual Pauli matrices,
This connects the Poincaré sphere to the Bloch-sphere representation of a two-level quantum system.
Transformations of Stokes parameters
Rotation of reference axes
If the transverse axes are rotated through an angle , with
the Stokes parameters transform as
Thus and depend on the chosen axes, whereas , , and the total degree of polarization are invariant under this rotation.
Mueller matrices
An optical element or propagation system can often be represented by a real Mueller matrix:
This formalism describes polarizers, retarders, reflection, scattering, and depolarizing systems. A deterministic Jones transformation acts on the coherence matrix as
and induces a corresponding Mueller transformation. Depolarizing Mueller matrices require a more general description than a single Jones matrix, such as an ensemble of unresolved transformations.
An ideal lossless retarder rotates the polarization vector on the Poincaré sphere while preserving and . A depolarizer can reduce , whereas a polarizer can increase it by selectively transmitting particular polarization components. Not every arbitrary real matrix represents a physically realizable optical system.
Measurement
The experimental determination of Stokes parameters is called polarimetry. For ideal, consistently calibrated analyzer measurements,
where and are intensities in circular analyzer states defined consistently with the chosen sign convention.
A linear analyzer at angle transmits
This expression contains no , so rotating a linear polarizer alone cannot determine circular polarization. A phase-sensitive optical element, such as a quarter-wave plate, can convert circular polarization into a measurable linear component. Retarders commonly exploit birefringence.
At least four linearly independent intensity measurements are needed to recover four unrestricted Stokes parameters. Practical instruments often use additional measurements to improve noise performance or suppress systematic errors. Calibration must account for detector gain differences, imperfect retardance, instrumental polarization, and cross-talk between parameters.
Because and involve nonnegative square roots of squared noisy measurements, their direct estimates are biased upward at low signal-to-noise ratio. Noise can also produce reconstructed vectors outside the physical region. Statistical estimation may therefore incorporate physical constraints and a measurement-noise model.
Applications and limitations
In astronomy, Stokes measurements constrain radiation mechanisms and the geometry of magnetic fields. Synchrotron radiation can exhibit strong linear polarization, while circular polarization and polarized spectral lines provide additional diagnostics. Polarization can also change during propagation, so observed parameters reflect both emission and intervening material.
In atmospheric and planetary remote sensing, polarization provides information about scattering, aerosols, clouds, and surface properties. Polarized radiative transfer treats intensity and polarization together, generally evolving a Stokes vector rather than a single scalar intensity.
In optical engineering, the parameters characterize sources, fibers, coatings, displays, and imaging systems. Combined with suitable models, they help distinguish selective absorption, phase retardation, and depolarization.
The four parameters completely specify the local second-order polarization statistics of a transverse field under the stated averaging conditions. They do not specify its full spectrum, absolute phase, higher-order fluctuations, or correlations between different positions and times. A single four-component vector is also insufficient for a general three-dimensional field with an appreciable longitudinal electric component.
Depolarization is resolution-dependent. Unresolved mixtures of individually fully polarized fields can yield a partially polarized or unpolarized measurement. Spatial, temporal, or spectral integration can therefore change the measured degree of polarization even when each resolved contribution is fully polarized.