A semipermeable membrane is a barrier that allows certain substances to pass through while restricting others. In the classical description of osmosis, it permits a solvent, usually water, to cross but prevents the passage of one or more dissolved substances. More broadly, the term describes biological and artificial membranes whose permeability differs among substances. Their selectivity depends on molecular size, charge, solubility, and interactions with the membrane, rather than simply on the presence of microscopic holes.
Definition and terminology
Semipermeability is a relative property: a membrane is permeable to particular substances under specified conditions, not universally “permeable” or “impermeable.” A membrane that retains a large protein may freely transmit water and small dissolved salts. Another may allow water through while strongly restricting those same salts.
The terms semipermeable, selectively permeable, and partially permeable overlap in ordinary scientific usage. A useful distinction is that an ideal semipermeable membrane passes solvent while completely excluding solute, whereas a selectively permeable membrane may discriminate among several solvents, solutes, or ions. Biological membranes generally fit the broader description.
Real membranes are not perfectly selective. A substance described as rejected may still cross slowly, and its transmission can change with temperature, solution composition, membrane condition, and applied pressure.
Mechanisms of selective transport
Several mechanisms can contribute to a membrane’s selectivity.
- Size exclusion: pores restrict particles or molecules that cannot enter or move efficiently through them. Effective size includes hydration and molecular shape, not just the dimensions of an isolated molecule.
- Partitioning and diffusion: a substance dissolves in the membrane material and then moves through it by diffusion. Substances with different solubilities and mobilities cross at different rates.
- Electrostatic interactions: charged membrane surfaces and internal groups influence the entry and transport of ions.
- Specific transport pathways: biological channels and carriers recognize particular substances and provide routes that are unavailable through the surrounding membrane material.
Porous membranes often behave partly like molecular sieves. Dense polymer membranes, including many used for desalination, are commonly described using a solution–diffusion model rather than as sheets containing fixed, open pores. These are useful descriptions of transport, not a universal division: the dominant mechanism depends on the membrane and operating conditions.
A membrane’s selectivity describes how strongly it favors one substance over another. Its flux is the amount of material crossing a unit area per unit time. High selectivity does not necessarily imply high flux.
Osmosis and osmotic pressure
When a membrane passes solvent but retains solute, net solvent movement is governed by differences in the solvent’s chemical potential. At equal pressure and temperature, water generally moves from a more dilute solution toward a more concentrated one, provided the relevant solute is retained by the membrane.
This does not mean that individual water molecules move in only one direction. Molecular exchange occurs both ways; osmosis is the net movement resulting from unequal opposing fluxes.
The osmotic pressure of a solution is the excess pressure required to prevent net solvent entry across an ideal semipermeable membrane relative to pure solvent. For a sufficiently dilute ideal solution,
where is osmotic pressure, is the molar concentration of dissolved formula units, is the gas constant, is absolute temperature, and accounts for the effective number of dissolved particles produced per formula unit. For an ideal, nondissociating solute, . Concentrated solutions and interacting solutes require descriptions based on solvent activity rather than this dilute-solution approximation.
A common approximate expression for pressure-driven solvent transport is
where is volumetric flux per unit membrane area, is hydraulic permeability, and and are the pressure and osmotic-pressure differences measured with the same side-to-side convention. The reflection coefficient describes the effectiveness of solute exclusion: an ideal retained solute has , while a freely permeating solute has little sustained osmotic effect and approaches zero. This relation is an approximation for specified membrane–solution systems, not a universal transport law.
Biological membranes
The cell membrane separates a cell’s interior from its surroundings. Its lipid bilayer permits some small, uncharged molecules to cross relatively readily while presenting a substantial barrier to ions and many polar molecules.
Embedded proteins greatly extend its selective functions. An ion channel provides a pathway for particular ions, while water channels called aquaporins can greatly increase water permeability. Carrier proteins transport specific solutes, and pumps can move substances against their electrochemical gradients using energy, often supplied through ATP hydrolysis.
Semipermeability itself is not an energy-consuming process. Passive transport follows the relevant chemical or electrochemical driving force; active transport requires an energy source. Together, selective barriers and transport proteins enable cells to maintain different internal and external compositions.
The osmotic effect of a substance on a cell depends on whether it can cross the membrane over the timescale considered. Consequently, two solutions with the same total concentration of dissolved particles need not produce the same sustained change in cell volume.
Artificial membranes and applications
Artificial membranes are made from polymers, ceramics, and other materials. Their structures range from porous sheets and hollow fibers to composites containing a very thin selective layer supported by a stronger porous substrate.
Reverse osmosis
In reverse osmosis, pressure is applied to a solution to drive solvent through a membrane in the direction opposite to spontaneous osmosis. The applied pressure must overcome the opposing osmotic-pressure difference and transport resistance.
Reverse osmosis is used in seawater desalination, treatment of brackish water, wastewater reuse, and production of high-purity water. The membrane produces a solvent-rich permeate and a more concentrated retained stream. Rejection is substance-specific: strong salt rejection does not imply complete exclusion of every small neutral compound.
Dialysis and laboratory separation
In dialysis, diffusible solutes cross a membrane while larger retained components remain behind. Laboratory dialysis commonly removes salts or exchanges the buffer surrounding a protein solution. Its principal driving force is a solute concentration difference, unlike pressure-driven filtration.
Medical hemodialysis also uses selective membranes to exchange dissolved substances between blood and a dialysis fluid; fluid removal is additionally controlled through pressure differences.
Related filtration processes
Microfiltration, ultrafiltration, and nanofiltration provide different, partly overlapping ranges of separation. Ultrafiltration commonly retains proteins and other macromolecules, whereas nanofiltration can discriminate among smaller solutes and ions.
These membranes are often described as semipermeable in the broad sense. However, retaining suspended particles while allowing most dissolved substances through is not equivalent to the ideal solvent-only membrane used in osmotic theory.
Historical development
Experiments with animal membranes helped establish osmosis as a distinct phenomenon in the eighteenth century. In the nineteenth century, artificial precipitate membranes, notably copper ferrocyanide membranes supported within porous vessels, enabled more systematic measurements of osmotic pressure.
Wilhelm Pfeffer’s measurements provided important experimental evidence for dilute-solution behavior. Jacobus Henricus van ’t Hoff subsequently developed its theoretical relationship to gas laws. During the twentieth century, advances in polymer chemistry and asymmetric membrane fabrication made high-throughput membrane separations increasingly practical.
Performance and limitations
Membrane performance is normally characterized by flux, permeability or permeance, and rejection of specified substances. Observed solute rejection is often written as
where is the permeate concentration and is a specified feed-side reference concentration. Reported values depend on test conditions and on where the feed concentration is measured.
Several effects limit performance:
- Concentration polarization: retained substances accumulate near the membrane surface, changing the local driving force and potentially increasing osmotic resistance.
- Fouling: particles, organic matter, or biological growth obstruct transport or alter the membrane surface.
- Scaling: sparingly soluble salts precipitate on or within the membrane.
- Degradation and defects: chemical attack, compaction, swelling, and mechanical damage can change permeability and selectivity.
Manufacturers may specify a molecular-weight cutoff, but it is an operational rating measured under particular conditions, not an exact boundary between molecules that pass and molecules that are retained. Molecular shape, charge, solution chemistry, and interactions with the membrane can all affect the result.