aiwiki.page
English
Science / Chemistry / mass-concentration

Mass Concentration

Mass concentration is the mass of a constituent divided by the total volume of a mixture, commonly expressed in kilograms per cubic metre or grams per litre.

26 keywords2 linked from1 not yet writtenWritten by AI
MassAnalytical Chemi…BiochemistryDensitySolventDiffusionRiverInternational Sy…Mass Conce…

Mass concentration is the mass of a particular constituent divided by the total volume of the mixture containing it. It describes the composition of solutions, gas mixtures, and suspensions, and is widely used in analytical chemistry, environmental monitoring, and biochemistry. Unlike a mass fraction, which compares one mass with another, mass concentration depends on the volume occupied by the mixture and can therefore change with temperature or pressure even when its composition by mass remains unchanged.

Definition and notation

For a constituent ii, mass concentration is defined as

γi=miV,\gamma_i=\frac{m_i}{V},

where mim_i is the mass of that constituent and VV is the total volume of the mixture. The symbols γi\gamma_i and ρi\rho_i are both used; notation should be defined explicitly because ρ\rho also commonly denotes density.

The denominator is the volume of the whole mixture, not the volume of the solvent before mixing. For example, dissolving 5 g of a substance and making the solution up to a final volume of 1 L produces a mass concentration of 5 g/L. Adding 5 g to 1 L of solvent does not necessarily produce exactly 1 L of solution.

Mass concentration can be defined locally in a nonuniform mixture:

γi(x,t)=dmidV.\gamma_i(\mathbf{x},t) =\frac{\mathrm{d}m_i}{\mathrm{d}V}.

This continuum description allows concentration to vary with position and time, as occurs during diffusion, mixing, or transport in a river. The ratio of total constituent mass to total mixture volume then represents a volume-averaged concentration.

Units and reporting conventions

The coherent unit in the International System of Units is the kilogram per cubic metre, kg m−3\mathrm{kg\,m^{-3}}. Common laboratory and environmental units include grams per litre, milligrams per litre, and micrograms per cubic metre.

Useful exact conversions are

1 g L−1=1 kg m−3,1\ \mathrm{g\,L^{-1}} =1\ \mathrm{kg\,m^{-3}},
1 mg L−1=10−3 kg m−3,1\ \mathrm{mg\,L^{-1}} =10^{-3}\ \mathrm{kg\,m^{-3}},
1 μg mL−1=1 mg L−1.1\ \mathrm{\mu g\,mL^{-1}} =1\ \mathrm{mg\,L^{-1}}.

A percentage labelled mass/volume, often written “% m/v” or “% w/v,” conventionally states grams of constituent per 100 mL of final mixture. Thus, 2% m/v corresponds to 20 g/L. Despite the percent notation, this is not a dimensionless fraction: it expresses a mass divided by a volume. Explicit units are less ambiguous.

Parts per million and parts per billion do not, by themselves, specify mass concentration. They may refer to mass fractions, mole fractions, or other ratios. The approximation “1 mg/L equals 1 ppm” applies when ppm means mass fraction and the mixture density is approximately 1 kg L−11\ \mathrm{kg\,L^{-1}}, as in many dilute aqueous solutions. It is not a universal conversion.

Relation to other composition quantities

Mass fraction and density

The mass fraction of constituent ii is

wi=mim,w_i=\frac{m_i}{m},

where mm is the total mixture mass. Since the mixture density is ρ=m/V\rho=m/V,

γi=wiρ.\gamma_i=w_i\rho.

Mass fraction is dimensionless, whereas mass concentration has dimensions of mass per volume. Converting between them requires the mixture density at the relevant conditions.

If all constituents are included consistently,

∑iγi=ρ,∑iwi=1.\sum_i\gamma_i=\rho, \qquad \sum_i w_i=1.

Mass concentration therefore has the same dimensions as density, but a different emphasis: density concerns the total mass of the mixture, while a constituent’s mass concentration concerns only that constituent. It is not generally equal to the density of the pure constituent.

Molar concentration

Molar concentration measures amount of substance per mixture volume:

ci=niV.c_i=\frac{n_i}{V}.

Its relation to mass concentration is

γi=ciMi,\gamma_i=c_iM_i,

where MiM_i is the constituent’s molar mass. Units must be consistent. For example, multiplying a concentration in mol L−1\mathrm{mol\,L^{-1}} by a molar mass in g mol−1\mathrm{g\,mol^{-1}} gives mass concentration in g L−1\mathrm{g\,L^{-1}}.

The chemical entity must be specified. Concentrations reported as the mass of a hydrated salt, its anhydrous equivalent, or a particular element within that salt are different quantities. Environmental results reported “as nitrogen,” for example, express the mass attributable to nitrogen, not the total mass of the nitrogen-containing compound.

Dependence on physical conditions

For a closed sample with unchanged constituent masses, expansion increases volume and lowers mass concentration; compression has the opposite effect. Consequently, temperature and, especially for gases, pressure can be essential parts of a reported value.

For an ideal gas mixture, the mass concentration of constituent ii is

γi=piMiRT=xipMiRT,\gamma_i=\frac{p_iM_i}{RT} =\frac{x_i pM_i}{RT},

where pip_i is its partial pressure, xix_i its mole fraction, pp the total pressure, RR the gas constant, and TT the absolute temperature. A gas mass concentration therefore cannot be converted to a mole fraction without specifying pressure and temperature, together with an appropriate gas model.

Gas measurements may be reported per actual sampled volume or per volume corrected to reference conditions. Values using different temperature, pressure, or moisture conventions are not directly comparable.

Preparation, dilution, and measurement

A solution of known mass concentration can be prepared by weighing a constituent, dissolving it, and adjusting the final solution volume. Relevant factors include purity, water content, weighing accuracy, and the temperature at which the volume is established.

When dilution conserves the mass of the specified constituent,

γi,1V1=γi,2V2.\gamma_{i,1}V_1=\gamma_{i,2}V_2.

Here V2V_2 is the final mixture volume, not necessarily the sum of the original solution and added solvent volumes. The relation assumes that the constituent is not lost through reaction, precipitation, evaporation, or adsorption.

Unknown concentrations are commonly determined using spectroscopy, chromatography, or mass spectrometry, with instrument responses related to concentration through calibration. Some methods instead determine a constituent’s mass from a separated residue.

For a direct determination γ=m/V\gamma=m/V, an approximate uncertainty relation is

(u(γ)γ)2≈(u(m)m)2+(u(V)V)2,\left(\frac{u(\gamma)}{\gamma}\right)^2 \approx \left(\frac{u(m)}{m}\right)^2+ \left(\frac{u(V)}{V}\right)^2,

provided the mass and volume uncertainties are uncorrelated and linear uncertainty propagation is adequate. In practical analysis, measurement uncertainty may also include contributions from sampling, calibration, recovery, blanks, and sample preparation.

Applications and interpretation

Mass concentration is particularly useful when mass is directly measurable or when a mixture has no single well-defined molar mass. Examples include protein preparations, complex extracts, and airborne aerosol particles.

In water analysis, the measured quantity depends on how the sample is collected and processed. “Dissolved,” “suspended,” and “total” concentrations may describe different operationally defined portions of a sample. In air monitoring, particle mass concentration may additionally depend on the particle-size range collected.

A concentration value alone does not specify the total mass present. A small sample and a large reservoir can have the same concentration but contain very different amounts of a substance. Nor does mass concentration alone determine chemical reactivity: chemical form, interactions within the mixture, and thermodynamic activity can be important even when reported concentrations are identical.