Machine perfusion is a method of preserving donor organs by circulating a specially formulated fluid, called a perfusate, through their blood vessels using an external device. Used in organ transplantation, it provides controlled conditions of flow, pressure, and temperature, with oxygen delivery in many systems. Depending on the organ and technique, machine perfusion can support preservation, permit functional assessment, and reduce particular forms of preservation injury. It differs from static cold storage, in which an organ is cooled in preservation solution without continuous circulation.

Biological principles

After an organ loses its normal blood supply, its cells receive insufficient oxygen and nutrients. This interruption, called ischemia, limits production of adenosine triphosphate (ATP), the principal energy carrier used by cells. Energy depletion impairs ion transport, promotes cellular swelling, and disrupts normal metabolism.

Cooling slows these processes but does not stop them completely. Restoring blood flow during transplantation can produce additional damage through oxidative stress, vascular dysfunction, and inflammation. Together, these processes are known as ischemia–reperfusion injury.

Machine perfusion modifies the organ’s environment during preservation. Low-temperature systems primarily suppress metabolic demand while maintaining circulation; oxygenated systems can also support energy metabolism. Warmer systems provide more active metabolic support and allow observation of functions that are difficult to assess in a deeply cooled organ. None of these approaches completely reproduces the physiological environment of a living body.

Equipment and perfusate

A typical system includes an organ chamber, a pump, tubing connected to the organ’s vessels, a reservoir, temperature control, and sensors. Depending on the technique, it may also include an oxygenator, filters, and equipment for sampling fluid or removing metabolic waste.

Important monitored variables include:

  • Perfusion pressure and flow.
  • Temperature.
  • Oxygen delivery and consumption.
  • pH and electrolyte concentrations.
  • Organ-specific products, such as urine or bile.

Perfusates differ substantially between systems. Cold-perfusion solutions generally contain substances intended to limit cell swelling and preserve tissue integrity. Normothermic solutions commonly include nutrients, buffers, and an oxygen carrier, such as red blood cells. Not every machine-perfusion protocol uses blood, and not every cold-perfusion system actively adds oxygen.

Flow and pressure must suit the organ’s vascular structure. Excessive pressure or inappropriate fluid composition can damage small vessels or cause edema.

Main approaches

Hypothermic machine perfusion

Hypothermic machine perfusion generally operates at approximately 4–12 °C, although protocols vary. The low temperature substantially reduces metabolic demand. It is particularly established in kidney preservation.

Hypothermic oxygenated perfusion adds controlled oxygen delivery at low temperature. It is used in liver preservation and in some kidney protocols. Oxygenation can support restoration of cellular energy stores before the organ is exposed to warm, oxygenated blood during implantation.

Cold-perfusion measurements, such as vascular resistance, provide information about circulation through an organ but do not independently establish whether transplantation will succeed.

Normothermic machine perfusion

Normothermic machine perfusion maintains an organ near physiological temperature, commonly around 35–37 °C. It supplies oxygen and metabolic substrates to support active tissue function.

Because the organ is metabolically active, this approach can permit assessment of features such as lactate metabolism, bile production, urine production, or cardiac activity. The relevant measurements and their interpretation differ between organs.

Normothermic perfusion requires close control of oxygen delivery and perfusate composition. Interruption of circulation at warm temperatures can rapidly expose the organ to renewed ischemia.

Intermediate-temperature and rewarming techniques

Subnormothermic perfusion uses temperatures between conventional cold preservation and physiological temperature. Controlled oxygenated rewarming gradually raises the temperature of a cold-preserved organ.

These approaches seek to manage the transition between suppressed and active metabolism. Their clinical use and evidence base are less established than those of the principal cold and normothermic techniques.

Applications by organ

Kidneys

Kidney machine perfusion is the longest-established clinical application. Evidence from randomized controlled trials supports a reduction in delayed graft function with hypothermic machine perfusion compared with static cold storage in deceased-donor kidney transplantation. Delayed graft function commonly refers to the need for dialysis during the first week after transplantation, although study definitions can differ.

Normothermic kidney perfusion is also used in selected settings and investigated for functional assessment. Urine production alone does not demonstrate adequate filtration or tubular function.

Livers

Both hypothermic oxygenated perfusion and normothermic perfusion are used for donor livers. Randomized trials have demonstrated benefits for particular outcomes, including reductions in some forms of early graft injury or biliary complications, depending on the technique and donor population.

During normothermic perfusion, assessment may include lactate clearance, acid–base balance, vascular flows, and bile production and composition. No single measurement reliably captures the condition of every part of the liver; hepatocyte function and bile-duct integrity require distinct consideration.

Lungs

Ex vivo lung perfusion combines circulation through the pulmonary vessels with mechanical ventilation. It allows assessment of gas exchange, pulmonary vascular behavior, and lung mechanics outside the donor’s body.

This approach can support evaluation of selected lungs whose suitability is uncertain after initial donor assessment. Protocols differ in temperature, perfusate composition, and operating conditions.

Hearts and other organs

Heart-perfusion systems circulate an oxygenated perfusate through the coronary vessels. Some maintain a warm, beating heart, whereas others use hypothermic oxygenated preservation. Visible beating alone is not equivalent to a complete assessment of the heart’s ability to support a recipient’s circulation.

Perfusion of the pancreas, intestine, and other tissues is under investigation, with less established routine clinical use.

Preservation and viability assessment

Machine perfusion has two related but distinct roles: maintaining an organ during preservation and generating information about its condition. Better preservation does not necessarily imply that the device can reliably classify every organ as suitable or unsuitable for transplantation.

Assessment can combine donor history, appearance, perfusion behavior, biochemical measurements, and, where applicable, biopsy. Proposed biomarkers and acceptance thresholds vary between centers and protocols. Favorable short-term measurements do not guarantee long-term graft survival or exclude every form of tissue injury.

Perfusion measurements may also function as surrogate endpoints in research. Their clinical value depends on how well they predict meaningful recipient outcomes.

Historical development

Experimental organ perfusion predates modern transplantation. During the twentieth century, advances in pumps, preservation solutions, and vascular cannulation enabled isolated organs to be maintained under increasingly controlled conditions.

Kidney machine perfusion entered clinical practice before comparable approaches became established for other solid organs. Static cold storage nevertheless became widely used because of its relative simplicity and portability.

Subsequent improvements in portable equipment, oxygenation, monitoring, and organ-specific protocols expanded clinical use to the liver, lungs, and heart. Contemporary development emphasizes both preservation quality and assessment of organs that might otherwise be declined.

Limitations and distinction from related techniques

Machine perfusion requires equipment, consumables, trained personnel, and reliable transport and operating arrangements. Device malfunction, vessel injury during cannulation, contamination, hemolysis in blood-containing circuits, and inadequate perfusion are potential complications.

Evidence cannot be transferred automatically between organs, temperatures, or perfusion protocols. Studies also differ in donor characteristics, duration of perfusion, prior cold-storage time, and chosen outcomes. Effects on early graft function do not necessarily establish effects on long-term survival or overall cost.

Machine perfusion does not eliminate transplant rejection or replace recipient immunosuppression.

Most transplant machine perfusion is performed outside the donor’s body. It is distinct from normothermic regional perfusion, which restores oxygenated circulation to a defined region within a deceased donor before organ recovery. The two techniques can be used within the same donation pathway, but they differ in anatomy, operation, and governance.