International Atomic Time (TAI) is a continuous international time scale calculated by the International Bureau of Weights and Measures (BIPM) from measurements supplied by atomic clocks and frequency standards around the world. Its scale interval is intended to realize the SI second at a conventional terrestrial reference gravitational potential. TAI provides the atomic-time foundation of Coordinated Universal Time (UTC), the basis of civil timekeeping. Unlike UTC, TAI does not insert leap seconds to maintain an approximate relationship with the rotation of Earth. Its abbreviation comes from the French name Temps atomique international.
Physical basis
The atomic second
The International System of Units defines the second by fixing the frequency of a specified transition in the ground state of the caesium-133 atom at exactly hertz. An ideal realization therefore associates one second with periods of the radiation corresponding to that transition.
An atomic clock uses an atomic resonance to control an oscillator. Because atomic transition frequencies are highly reproducible, they provide a more uniform basis for measuring elapsed time than astronomical observations of Earth's rotation. Atomic clocks nevertheless have noise and systematic frequency shifts: no individual clock reproduces the ideal second perfectly.
TAI is consequently not the output of one master clock. It is an internationally computed ensemble time scale, whose stability comes from combining many clocks and whose rate is calibrated using particularly accurate frequency standards.
Relativistic reference
Clock rates depend on motion and gravitational potential, as described by special relativity and general relativity. Two otherwise identical clocks at different elevations can accumulate different amounts of elapsed time because of gravitational time dilation.
Measurements contributing to TAI must therefore be referred to a common relativistic convention. Its rate corresponds to the SI second at a conventional reference potential associated with the terrestrial geoid, rather than to the uncorrected proper time of every participating clock.
This distinction becomes important at high accuracy. Near Earth's surface, a height difference of about one metre corresponds to a fractional gravitational frequency difference of approximately . Relativistic corrections are therefore part of practical time metrology, not merely a theoretical refinement.
How TAI is calculated
An international clock ensemble
National metrology institutes, observatories, and other timing laboratories maintain local clocks and time scales. Participating equipment includes commercial caesium clocks and hydrogen masers. Laboratories compare these clocks locally and establish international time links, principally through satellite-based techniques.
The BIPM uses these measurements to determine the relative behavior of clocks distributed among the participating laboratories. The calculation has two conceptually distinct stages:
- Constructing a stable ensemble time scale. A weighted algorithm combines clock data into Free Atomic Time, known by its French abbreviation EAL, from Échelle atomique libre. Weighting and clock-performance prediction reduce the influence of less stable clocks and prevent excessive dependence on an individual instrument.
- Calibrating the ensemble's rate. Evaluations from primary and secondary frequency standards establish how the ensemble's scale interval differs from the SI second. Frequency corrections are then used to obtain TAI.
This separates short- and medium-term stability from long-term accuracy. A continuously running clock may be excellent at maintaining a smooth signal, while a frequency standard operated for limited measurement intervals can provide a more accurate determination of the SI second.
Primary and secondary frequency standards
Primary frequency standards realize the defining caesium transition with evaluated systematic corrections and measurement uncertainty. Caesium fountain standards are an important example: laser-cooled atoms move through a microwave interrogation region, enabling highly accurate frequency measurements.
Secondary frequency standards use other atomic transitions whose recommended frequencies have been established in relation to the SI second. These include microwave and optical transitions. Qualified evaluations from secondary standards can also contribute to the calibration of TAI.
The calculations take account of the uncertainty of the standards and their comparisons, including the effects of measurement duration and gaps in operation. The resulting connection between the time scale and the SI second is an example of metrological traceability.
Retrospective publication and real-time access
The definitive international time-scale results are computed retrospectively. The BIPM publishes time differences and related information in its monthly Circular T. A laboratory's local realization of UTC is designated UTC(), where identifies the laboratory. Published differences between UTC and UTC() allow users to relate local timing signals to the international scale.
TAI itself is therefore not a single radio signal broadcast from a central clock. Real-time users normally obtain time through local timing services, satellite navigation systems, or network services, whose relationship to international time must be established through documented comparisons.
The BIPM also produces Rapid UTC, or UTCr, on a shorter reporting cycle to help laboratories monitor their local realizations more promptly.
Relationship to other time scales
Coordinated Universal Time
UTC and TAI have the same rate apart from the discontinuities introduced by leap seconds. Under the system introduced in 1972, their difference is an integer number of seconds:
where .
At the start of 1972, this difference was 10 seconds. The positive leap second inserted at the end of 31 December 2016 increased it to 37 seconds, effective from 1 January 2017. Thus, during an interval when that offset applies,
That number is date-dependent, not a permanent defining constant. Conversion of historical timestamps requires the appropriate offset history. Before 1972, UTC used a different adjustment system, so the modern integer-offset rule must not simply be extended backward.
Leap seconds change the relationship between UTC and TAI; they do not interrupt TAI itself.
Universal Time and Earth's rotation
Universal Time, particularly UT1, measures Earth's rotation rather than atomic elapsed time. Earth's rotation is irregular and changes under the influence of tidal interactions, exchanges of angular momentum among the solid Earth, atmosphere, and oceans, and other processes.
Consequently, UT1 does not remain at a fixed offset from TAI. In the leap-second system established in 1972, UTC is adjusted to keep its difference from UT1 within 0.9 seconds. The International Earth Rotation and Reference Systems Service monitors Earth orientation and announces leap seconds under the applicable arrangements.
In 2022, the General Conference on Weights and Measures decided that the permitted difference between UT1 and UTC should be increased by or before 2035. This concerns the future adjustment of UTC, not the continuity of TAI.
Terrestrial Time
Terrestrial Time (TT) is a theoretical time scale used in geocentric astronomy and related calculations. Its commonly used realization based on TAI is defined by
The 32.184-second offset is fixed by convention and preserves continuity with earlier astronomical timekeeping. It is unrelated to the changing number of leap seconds.
TT(TAI) is a realization of TT, not an assertion that TAI has no measurement error. The BIPM also produces retrospective realizations designated TT(BIPM), using additional analysis of frequency-standard data to improve long-term rate accuracy.
Satellite navigation time
Satellite navigation systems generally maintain their own continuous system times, with documented relationships to TAI or UTC. For example, GPS time was aligned with UTC at its epoch in January 1980 and does not insert leap seconds. Its nominal relationship is
Actual system realizations have small timing errors, so precise work requires the relevant clock corrections. Not all satellite navigation systems use the same time scale or offset.
Historical development
Early international timekeeping depended on astronomical observations, initially of Earth's rotation and later also on dynamical descriptions of celestial motion. The development of practical caesium clocks in the 1950s made possible a substantially more uniform time scale.
TAI's historical origin was chosen so that it approximately coincided with UT2, a seasonally corrected form of Universal Time, at the beginning of 1958. This origin establishes an epoch convention; it does not make Earth's rotation the continuing basis of TAI.
In 1967, the General Conference on Weights and Measures adopted the caesium-based definition of the second. International recognition and organization of TAI followed in the early 1970s, alongside the introduction of the modern leap-second form of UTC in 1972.
The Bureau International de l'Heure originally carried out the international atomic-time calculations. Responsibility transferred to the BIPM in 1988. Subsequent improvements have included better clock-ensemble algorithms, satellite time transfer, caesium fountain standards, and contributions from optical frequency standards.
Uses and limitations
TAI provides a continuous reference for precise elapsed-time measurements and for relating measurements made at different laboratories. It supports frequency calibration, astronomical observations, satellite-system timing, and the international consistency of UTC.
Its continuity is particularly useful when an interval crosses a UTC leap second. Subtracting two civil timestamps without accounting for their time scale and the leap-second history can produce an incorrect elapsed duration. A properly interpreted atomic-time representation avoids that ambiguity.
TAI nevertheless has practical limitations:
- Final results are retrospective. Real-time applications depend on local clocks and operational realizations rather than immediate access to the final computed scale.
- Its realization has uncertainty. Clock noise, systematic frequency shifts, imperfect time transfer, and frequency-standard uncertainties affect the result.
- It does not track the solar day. TAI alone is unsuitable for describing Earth's rotational orientation or directly maintaining civil time's relationship to the Sun.
- A timestamp requires a stated convention. A date and clock reading without a specified time scale may be ambiguous by seconds or more. TAI is also distinct from a time zone or a calendar.
Advances in optical clocks and time-transfer methods can improve TAI and support a future redefinition of the SI second. Such a redefinition would change how the unit is realized, while the international time scale would need to preserve continuity.