Farad

The farad (F) is the SI unit of capacitance, equal to one coulomb of electric charge per volt of potential difference.

22 keywords1 linked fromWritten by AI
CapacitanceInternational Sy…CoulombVoltMichael FaradayCapacitorElectric ChargeElectric CurrentFarad

The farad, symbol F, is the unit of capacitance in the International System of Units (SI). A device has a capacitance of one farad when a change of one coulomb in its stored charge corresponds to a change of one volt in the potential difference across it. Named after Michael Faraday, the farad is used to specify capacitors, characterize electrical materials and systems, and express the charge-storage behavior of interfaces.

Definition and unit relationships

For an ideal linear capacitor, capacitance is defined by

C=QV,C=\frac{Q}{V},

where CC is capacitance, QQ is the magnitude of the electric charge on either conductor, and VV is the potential difference between them. The two conductors carry charges of equal magnitude and opposite sign; QQ is not their net combined charge.

Thus,

1 F=1 CV.1\,\mathrm{F}=1\,\frac{\mathrm{C}}{\mathrm{V}}.

Here, the upright symbol C\mathrm{C} denotes the coulomb, whereas the italic CC denotes capacitance.

In SI base units,

1 F=1 kg−1 m−2 s4 A2.1\,\mathrm{F} = 1\,\mathrm{kg}^{-1}\,\mathrm{m}^{-2}\,\mathrm{s}^{4}\,\mathrm{A}^{2}.

The farad is therefore a coherent derived unit: its expression in base units requires no numerical factor other than one. Other useful relationships are

1 F=1 A sV=1 sΩ.1\,\mathrm{F} = 1\,\frac{\mathrm{A\,s}}{\mathrm{V}} = 1\,\frac{\mathrm{s}}{\Omega}.

The latter follows from the relationship between voltage, electric current, and electrical resistance.

When charge is not proportional to voltage, a local or differential capacitance can be defined as

Cdiff=dQdV.C_{\mathrm{diff}}=\frac{\mathrm{d}Q}{\mathrm{d}V}.

This quantity is also measured in farads, but its value may depend on the applied voltage and other operating conditions.

Physical interpretation

Capacitance describes how much charge can be separated for a given potential difference. A larger capacitance requires more charge to produce the same voltage.

For an ideal parallel-plate capacitor, neglecting edge effects,

C=εAd,C=\varepsilon\frac{A}{d},

where ε\varepsilon is the permittivity of the material between the plates, AA is their overlapping area, and dd is their separation. Capacitance therefore increases with plate area and permittivity and decreases with separation. A dielectric between the conductors affects capacitance through its electrical response.

The energy stored in an ideal linear capacitor is

E=12CV2.E=\frac{1}{2}CV^{2}.

A 1 F capacitor charged to 1 V consequently stores 1 C of charge on each conductor in opposite signs and contains 0.5 joule of stored electrical energy. Capacitance alone does not specify energy capacity: operating voltage is also essential.

For a constant capacitance,

I=CdVdt.I=C\frac{\mathrm{d}V}{\mathrm{d}t}.

An ideal 1 F capacitor carrying a constant current of 1 A therefore changes its voltage at a rate of 1 V per second.

Multiples, submultiples, and notation

One farad is large compared with the capacitance of many ordinary electronic components. Common submultiples include:

Unit Symbol Value in farads
Millifarad mF 10−3 F10^{-3}\,\mathrm{F}
Microfarad µF 10−6 F10^{-6}\,\mathrm{F}
Nanofarad nF 10−9 F10^{-9}\,\mathrm{F}
Picofarad pF 10−12 F10^{-12}\,\mathrm{F}

Picofarad values commonly occur in radio-frequency circuits and unintended capacitances between conductors. Nanofarad and microfarad values are widespread in filtering, timing, and power-supply circuits. Large electrolytic capacitors may have millifarad-scale capacitances, while supercapacitors can reach hundreds or thousands of farads.

Under SI conventions, the unit name is written in lowercase—farad—but its symbol is uppercase because it derives from a person's name. A space separates the numerical value from the unit symbol, as in 47 µF. Symbols do not take plural endings.

Applications in circuits

Capacitor values expressed in farads help determine how circuits respond over time and to varying signals.

For a simple resistor–capacitor circuit, the characteristic charging or discharging time is

τ=RC.\tau=RC.

When resistance is expressed in ohms and capacitance in farads, τ\tau is expressed in seconds.

For an ideal capacitor driven by a sinusoidal signal, the magnitude of its capacitive reactance is

XC=12πfC,X_C=\frac{1}{2\pi fC},

where ff is frequency. This relationship explains why capacitors present a lower opposition to higher-frequency alternating current. More generally, capacitance contributes to a circuit's electrical impedance.

Capacitance is also important outside discrete components. Cables, transistor structures, and neighboring conductors possess distributed or parasitic capacitance. Biological cell membranes separate charge across an insulating layer and are often characterized by capacitance per unit area, such as microfarads per square centimetre. That quantity is an area-normalized capacitance, not a capacitance measured in farads alone.

Measurement and practical limitations

Capacitance meters and impedance-measuring instruments determine capacitance through charging behavior or electrical response to a test signal. In precision metrology, standards and comparison methods establish metrological traceability, while calibration and stated measurement uncertainty characterize the reliability of measured values.

A real capacitor is not described completely by a single number in farads. Its behavior may also depend on:

  • Frequency, because dielectric response and internal electrical effects vary with the test signal.
  • Temperature and applied voltage, which can change effective capacitance.
  • Leakage and losses, which permit charge to escape or dissipate energy.
  • Parasitic resistance and inductance, which alter behavior, especially at high frequencies.
  • Dielectric absorption, which can cause voltage to reappear after discharge.

A nominal capacitance therefore normally accompanies a tolerance, voltage rating, and specified measurement conditions. Large capacitance does not by itself imply high energy density, low losses, or suitability for high-frequency operation.

Historical origin and related names

The farad developed during nineteenth-century efforts to establish consistent electrical units. Its use as a unit of capacitance was adopted by the International Electrical Congress in Paris in 1881. It subsequently became part of the SI when that system was established in 1960.

The unit honors Faraday's contributions to electricity and magnetism, including his work on electromagnetic induction and electrolysis.

The farad must not be confused with the faraday, a historical unit of electric charge corresponding to the charge of one mole of elementary charges. The related Faraday constant, also commonly represented by FF, has units of coulombs per mole, not farads.