A control volume is a selected region used to express balances of mass, momentum, energy, and other quantities through storage, boundary transport, and sources.

29 keywords4 linked from2 not yet writtenWritten by AI
MassMomentumEnergyFluid MechanicsThermodynamicsThermodynamic Sy…Chemical Reactio…EntropyControl Vo…

A control volume is a region of space selected for analyzing the transport and balance of physical quantities, especially mass, momentum, and energy. Its boundary, called the control surface, may be real or imaginary, and the region may be fixed, moving, or deforming. Matter can cross this boundary. Control-volume analysis is fundamental to fluid mechanics, thermodynamics, and engineering because it relates changes within a region to transfers across its boundary without requiring the motion of every individual particle to be followed.

Control volumes and material systems

A control volume is distinguished from a material system, or control mass, which consists of the same collection of matter throughout an analysis. A material system can change position and shape, but no matter crosses its boundary. By contrast, a control volume is defined geometrically, and the matter occupying it can change over time.

For example, a region enclosing a turbine remains in place while fluid enters and leaves. The fluid inside at one instant is generally not the same fluid present a short time later.

In the terminology of a thermodynamic system, a region permitting mass exchange is an open system. However, the control-volume method also applies when there is no mass transfer across the selected boundary. A boundary that moves with the material is the special case in which the control volume follows a material system.

The control surface can include:

  • Solid walls, through which fluid normally does not pass.
  • Inlet and outlet sections, through which matter flows.
  • Imaginary surfaces drawn through a fluid, such as a boundary surrounding a jet.
  • Moving interfaces, such as a piston face or a deforming free surface.

A control surface need not be a physical membrane. Its purpose is to define where storage and boundary transfers are evaluated.

General balance structure

A control-volume balance commonly takes the form

accumulation=inflow−outflow+net production.\text{accumulation} = \text{inflow} - \text{outflow} + \text{net production}.

Accumulation is the rate of change of the quantity stored inside the region. Inflow and outflow include the relevant transport mechanisms, while net production represents generation minus destruction within the volume.

The meaning of production depends on the quantity:

  • Total mass has no production term in ordinary nonrelativistic fluid mechanics.
  • A chemical species can be produced or consumed by a chemical reaction.
  • Momentum changes through applied forces.
  • Energy is transferred through heat, work, and matter; it is not created or destroyed.
  • Entropy can be generated by irreversible processes.

Transport across the surface is not limited to transport by bulk fluid motion. Diffusion, heat conduction, and stresses can also transfer quantities across it.

Reynolds transport theorem

The mathematical connection between a material-system description and a control-volume description is the Reynolds transport theorem.

Let BB be an extensive property of a material system, and let bb be its value per unit mass, so that B=∫b dmB=\int b\,dm. For a moving or deforming control volume,

dBsysdt=ddt∫V(t)ρb dV+∫S(t)ρb (u−vs)⋅n dA.\frac{dB_{\mathrm{sys}}}{dt} = \frac{d}{dt} \int_{V(t)} \rho b\,dV + \int_{S(t)} \rho b\,(\mathbf{u}-\mathbf{v}_s)\cdot\mathbf{n}\,dA.

Here:

  • V(t)V(t) is the control volume.
  • S(t)S(t) is its closed control surface.
  • ρ\rho is the density.
  • u\mathbf{u} is the material velocity.
  • vs\mathbf{v}_s is the local control-surface velocity.
  • n\mathbf{n} is the outward unit normal.

The first term on the right measures the change in the property contained in the control volume. The second is the net outward transport by matter crossing the moving surface.

For a fixed control volume, vs=0\mathbf{v}_s=0, giving

dBsysdt=∂∂t∫Vρb dV+∫Sρb u⋅n dA.\frac{dB_{\mathrm{sys}}}{dt} = \frac{\partial}{\partial t} \int_V \rho b\,dV + \int_S \rho b\,\mathbf{u}\cdot\mathbf{n}\,dA.

The theorem is a kinematic identity, not a conservation law by itself. Conservation equations follow when it is combined with the appropriate physical law.

Mass conservation

Applying conservation of mass gives

ddt∫V(t)ρ dV+∫S(t)ρ(u−vs)⋅n dA=0.\frac{d}{dt}\int_{V(t)}\rho\,dV + \int_{S(t)} \rho(\mathbf{u}-\mathbf{v}_s)\cdot\mathbf{n}\,dA =0.

For a fixed control volume with discrete inlet and outlet sections, this is often written

dmCVdt=∑inm˙−∑outm˙,\frac{dm_{\mathrm{CV}}}{dt} = \sum_{\mathrm{in}}\dot m - \sum_{\mathrm{out}}\dot m,

where the inlet and outlet mass-flow rates are defined as positive magnitudes.

For steady flow with one inlet and one outlet,

m˙in=m˙out.\dot m_{\mathrm{in}}=\dot m_{\mathrm{out}}.

If density and normal velocity are approximately uniform over each stationary cross-section,

m˙=ρAuˉn,\dot m=\rho A\bar u_n,

where AA is the section area and uˉn\bar u_n is the mean normal velocity, taken positive in the direction of flow.

Equal mass-flow rates do not necessarily imply equal volume-flow rates: a gas can change density substantially between inlet and outlet. The general expression is an area integral, and replacing it with a product of representative quantities requires appropriate averaging assumptions.

Momentum balance

Combining the transport theorem with Newton’s second law gives the linear momentum balance. In an inertial reference frame,

∑Fext=ddt∫V(t)ρu dV+∫S(t)ρu[(u−vs)⋅n] dA.\sum \mathbf{F}_{\mathrm{ext}} = \frac{d}{dt}\int_{V(t)}\rho\mathbf{u}\,dV + \int_{S(t)} \rho\mathbf{u} \left[(\mathbf{u}-\mathbf{v}_s)\cdot\mathbf{n}\right]\,dA.

External forces include surface forces due to pressure and viscous stresses, as well as body forces such as gravity.

The velocity carrying momentum is u\mathbf{u}, while the velocity determining the rate at which matter crosses the surface is u−vs\mathbf{u}-\mathbf{v}_s. This distinction is essential for moving control volumes.

Momentum balances are used to calculate forces on pipe bends, nozzles, blades, and jet-impact surfaces. Uniform-flow approximations may require correction factors when velocity varies significantly across a section.

An analogous balance for angular momentum relates external torque to angular-momentum storage and transport, providing a basis for analyzing turbines and pumps.

Energy balance

The first law of thermodynamics can be expressed for a fixed control volume with stationary inlet and outlet sections as

dECVdt=Q˙−W˙+∑inm˙(h+u22+gz)−∑outm˙(h+u22+gz).\frac{dE_{\mathrm{CV}}}{dt} = \dot Q-\dot W + \sum_{\mathrm{in}} \dot m \left(h+\frac{u^2}{2}+gz\right) - \sum_{\mathrm{out}} \dot m \left(h+\frac{u^2}{2}+gz\right).

Here Q˙\dot Q is the rate of heat transfer into the control volume, and W˙\dot W is the rate of work transfer out, excluding the pressure-flow work already incorporated in hh. The stored energy ECVE_{\mathrm{CV}} includes internal, kinetic, and potential energy.

The specific enthalpy is

h=e+pρ,h=e+\frac{p}{\rho},

where ee is specific internal energy. The term p/ρp/\rho accounts for pressure-flow work under the assumptions used in this common engineering form. Additional transport mechanisms or forms of energy must be included when relevant.

For steady flow with one inlet and one outlet,

Q˙−W˙=m˙[h2−h1+u22−u122+g(z2−z1)].\dot Q-\dot W = \dot m \left[ h_2-h_1 +\frac{u_2^2-u_1^2}{2} +g(z_2-z_1) \right].

Different approximations make this equation useful for turbines, compressors, nozzles, and heat exchangers. Neglecting a term requires a physical justification; steady operation alone does not make heat transfer, work, or kinetic-energy changes vanish.

Fixed, moving, and deforming control volumes

The choice of control volume can simplify a problem substantially.

Fixed control volumes are convenient for stationary equipment and flow through fixed pipe sections. A constant geometric volume can still contain a changing mass, as when a rigid tank fills with gas.

Moving control volumes can follow a translating object, such as a vehicle or moving nozzle. Boundary transport must then be evaluated using relative velocity.

Deforming control volumes change shape or size. Examples include regions bounded by moving pistons and computational cells that follow a changing interface.

When a boundary moves with the material in its normal direction,

(u−vs)⋅n=0,(\mathbf{u}-\mathbf{v}_s)\cdot\mathbf{n}=0,

so no mass crosses it. The complete boundary of a material system satisfies this condition.

Steady and unsteady analyses

A steady flow has no time dependence at fixed spatial positions. Consequently, storage terms vanish for a fixed control volume. Matter can nevertheless pass continuously through that volume, carrying mass, momentum, and energy.

An unsteady analysis retains storage terms. Examples include tank filling, equipment startup, and flood routing.

Steadiness depends on the reference frame. A pattern that changes with time in a stationary frame may be steady in a frame moving with it. Moreover, even in a steady spatial field, the amount of a property within a moving or deforming region can change as the region samples different parts of that field.

A zero storage term for one quantity does not establish complete steady operation. A vessel may maintain constant mass while its temperature and stored energy change.

Applications and numerical methods

Control-volume methods support several kinds of analysis:

  • Engineering equipment: performance and force calculations for pumps, turbines, ducts, and heat exchangers.
  • Hydrology: water budgets for a drainage basin, reservoir, or aquifer, including precipitation, discharge, infiltration, and evaporation.
  • Environmental transport: budgets for pollutants, heat, and chemical species.
  • Computational fluid dynamics: numerical approximation of flow and transport equations.

In the finite volume method, a computational domain is divided into small control volumes. Integral balance equations are applied to each cell. When a shared face flux is used consistently, the outward flux from one cell is the inward flux to its neighbor. Internal face contributions therefore cancel in the balance over the combined region, supporting discrete conservation.

Assumptions and limitations

A control-volume balance constrains overall behavior but does not necessarily determine the detailed fields inside the region. Equal total inlet and outlet mass-flow rates, for example, do not reveal recirculation zones, local velocities, or pressure distributions.

Solving a problem generally also requires constitutive relations, material properties, boundary conditions, and sometimes models for turbulence or reaction rates. A balance equation remains valid even when these additional approximations are poor.

The integral equations presented here use a continuum description. At scales where matter cannot adequately be treated as a continuous medium, microscopic or statistical descriptions may be needed.

Frequent errors include confusing a fixed volume with a fixed mass, omitting pressure forces from a momentum balance, counting pressure-flow work twice in an energy balance, and using absolute rather than relative velocity to calculate transport through a moving surface. Clear specification of the control surface, reference frame, sign conventions, and neglected terms is therefore part of the mathematical model.