Chemical shift is the displacement of a resonance frequency caused by the chemical environment of the species being observed. The term is used principally in nuclear magnetic resonance (NMR), where nuclei of the same isotope can resonate at different frequencies because their surrounding electrons modify the magnetic field they experience. Measured relative to a reference, chemical shifts provide information about molecular structure, bonding, conformation, and interactions. Related uses of the term occur in other forms of spectroscopy, where chemical environment changes the energy of a spectral feature.
Physical origin
An atomic nucleus with nonzero spin angular momentum can possess a magnetic moment. In an applied magnetic field, its allowed spin states have different energies, and transitions between these states occur at characteristic resonance frequencies.
The nucleus does not experience the applied field in isolation. The field also affects the surrounding electrons, whose response produces an additional local magnetic field. In a simplified description appropriate to an isotropic liquid,
where is the applied field and is the dimensionless magnetic shielding constant. The corresponding resonance frequency is approximately
where is the nuclear gyromagnetic ratio.
A larger shielding constant generally gives a lower resonance frequency at a fixed applied field. A nucleus with reduced shielding is described as deshielded and generally resonates at a higher frequency.
Shielding depends on the electronic structure around the nucleus, including chemical bonding, molecular geometry, and the response of occupied and unoccupied electronic states to the applied field. It is therefore not simply a measure of the amount of nearby electron density. Electronic circulation in neighboring groups can also produce substantial local fields.
Definition and units
The chemical shift of a sample resonance relative to a reference is defined by
with the frequencies compared under the same magnetic-field conditions. Chemical shift is dimensionless and is conventionally reported in parts per million, or ppm:
For example, a resonance 1,200 Hz above a reference frequency of 400 MHz has a chemical shift of approximately 3 ppm.
To first order, chemical shift is independent of magnetic-field strength because both the frequency difference and the reference frequency scale with the field. A separation of 1 ppm corresponds to approximately 400 Hz on a 400 MHz proton NMR instrument and 600 Hz on a 600 MHz instrument. Consequently, ppm values allow spectra recorded on different instruments to be compared, while frequency separations in hertz increase at higher fields.
For the same isotope under comparable conditions, chemical shift and shielding are related approximately by
when both quantities are expressed as dimensionless fractions.
Upfield and downfield
In conventional NMR plots, chemical shift increases from right to left.
- Downfield usually means higher chemical shift, higher resonance frequency at a fixed field, and lower shielding relative to the reference.
- Upfield usually means lower chemical shift, lower resonance frequency at a fixed field, and greater shielding.
These terms originated in instruments that swept the magnetic field while maintaining a fixed radiofrequency. The corresponding resonance frequencies provide the less ambiguous description for modern instruments.
Reference standards and measurement
Chemical shifts require a reference convention. For many organic solutions, tetramethylsilane (TMS) is used as the zero-point reference for proton and carbon-13 NMR. Its equivalent methyl groups produce a single proton resonance and a single carbon resonance, and its signals usually occur away from those of many common organic compounds.
Other reference compounds are used in aqueous samples, where TMS has limited solubility. Different nuclei, including fluorine-19 and phosphorus-31, have their own established reference conventions. Unified referencing procedures relate different nuclear frequency scales to a proton reference through specified frequency ratios.
Referencing may be:
- Internal: the reference compound is present in the sample.
- External: the reference is held separately, for example in a coaxial insert.
- Indirect: the scale is established through a calibrated frequency relationship or an assigned solvent resonance.
Internal references share much of the sample environment, but they can interact with the sample. External references avoid mixing but may require corrections for differences in bulk magnetic susceptibility and sample geometry. Residual signals from an incompletely deuterated solvent are convenient secondary references, although their positions can vary with conditions.
Reliable reporting identifies the observed nucleus, reference convention, solvent, and relevant experimental conditions. Temperature, concentration, pH, and sample composition may all affect measured shifts. Instrumental calibration and consistent referencing are particularly important when interpreting small changes.
Factors controlling chemical shift
Substituents and bonding
Electronegative substituents often deshield nearby nuclei. For example, a proton attached to carbon near oxygen commonly appears at a higher chemical shift than a proton in a simple saturated hydrocarbon environment. Such effects depend on distance, bonding pathways, geometry, and the complete molecular electronic structure.
Bond hybridization and multiple bonding also influence shielding. Carbon atoms in saturated, unsaturated, and carbonyl environments occupy broadly different regions of a carbon-13 spectrum. These differences make chemical shift a central tool of organic chemistry.
Magnetic anisotropy
Electrons in multiple bonds and aromatic rings respond directionally to the applied field. The induced local field can shield a nucleus in one region of space and deshield a nucleus elsewhere.
Aromatic ring currents commonly deshield protons around the outside of an aromatic ring. By contrast, the location of a terminal alkyne proton relative to the carbon–carbon triple bond helps explain why it is more shielded than a simple comparison of carbon hybridization might suggest. These examples show why chemical shifts cannot be predicted from electronegativity alone.
Hydrogen bonding and intermolecular interactions
Hydrogen bonding can substantially change the shifts of hydroxyl, amide, and other exchangeable protons. Their resonance positions may therefore depend strongly on solvent, concentration, temperature, and molecular association.
Coordination to a metal, protonation, and changes in oxidation state can also alter shifts. In species exhibiting paramagnetism, interactions involving unpaired electrons can produce shifts far outside the ranges typical of ordinary diamagnetic organic compounds.
Molecular motion and exchange
Observed shifts often represent averages over molecular motion. Rotation, conformational changes, and chemical exchange can interconvert environments.
If exchange is fast relative to the relevant resonance-frequency difference, a single averaged signal may appear. In the simple fast-exchange limit for two sites,
where and the values are the site populations.
Slow exchange can produce separate resonances, while intermediate exchange can broaden and distort them. Because the frequency difference in hertz depends on field strength, the same molecular exchange process can produce different line shapes on different instruments.
Typical proton and carbon-13 ranges
Approximate ranges help identify possible chemical environments, but they are not rigid boundaries.
| Environment | Typical proton shift, ppm |
|---|---|
| Simple alkyl groups | 0.5–2 |
| Protons near carbonyl groups or some unsaturated groups | 1.5–3 |
| Protons on carbon bonded to oxygen | 3–4.5 |
| Alkene protons | 4.5–6.5 |
| Aromatic protons | 6–9 |
| Aldehyde protons | 9–10.5 |
| Carboxylic acid protons | Often 10–13 |
Alcohol, amine, and other exchangeable proton shifts are particularly variable. Unusual compounds can also have negative shifts or signals well beyond these ranges.
Carbon-13 spectra typically span a much wider range. Saturated carbons commonly occur around 0–50 ppm, many saturated carbons bonded to oxygen around 50–90 ppm, alkene and aromatic carbons broadly around 100–160 ppm, and carbonyl carbons around 160–220 ppm. These ranges overlap, and individual assignments require additional evidence.
Chemical shift versus signal splitting
Chemical shift and spin–spin coupling describe different properties of an NMR spectrum.
Chemical shift identifies the resonance position associated with a nuclear environment. Spin–spin coupling is an interaction between nuclei that can split a resonance into several lines. Coupling constants, conventionally denoted , are normally reported in hertz and are approximately independent of applied field strength.
For a simple first-order multiplet, its center corresponds to the chemical shift, while the line spacing reflects coupling. More complex, strongly coupled spectra may not permit a straightforward reading of individual chemical shifts from peak maxima.
Chemically equivalent nuclei have the same chemical shift under specified conditions, but equal shifts do not necessarily establish chemical equivalence. Unrelated resonances may coincide accidentally, and magnetic equivalence imposes additional conditions on coupling relationships.
Liquids and solids
Rapid molecular tumbling in a low-viscosity liquid averages the directional components of shielding, usually leaving an isotropic shift. In a solid, this averaging is generally absent.
Shielding is more fully described by a second-rank tensor. Its isotropic component is
where the components are taken along the principal axes.
The orientation dependence produces chemical-shift anisotropy, which can broaden a static powder spectrum into a characteristic pattern. This anisotropy contains information about local bonding and structure.
Magic-angle spinning reduces many orientation-dependent interactions by rapidly rotating the sample at approximately to the applied field. Solid-state NMR can thereby resolve isotropic shifts, although spinning sidebands may remain. Chemical-shift tensors and isotropic shifts are both useful in studying crystals, glasses, polymers, and biological solids.
Applications and limitations
Chemical shifts are widely used to identify functional groups, distinguish molecular sites, and support structural assignments. Multidimensional NMR correlates shifts of different nuclei to establish connectivity and spatial relationships.
In proteins and nucleic acids, shifts are sensitive to local conformation and interactions. Deviations from suitable reference values can support the identification of secondary structure, including an alpha helix, while changes upon ligand binding can help identify affected regions. Such changes do not necessarily demonstrate direct contact: altered conformation, exchange, or solution conditions can also shift resonances.
In magnetic resonance imaging, the frequency difference between water and fat underlies chemical-shift artifacts and methods for separating their signals.
Chemical shift alone rarely establishes a unique molecular structure. Different environments can have overlapping shifts, and a single environment can move appreciably when experimental conditions change. Interpretation is therefore combined with coupling patterns, signal intensities, multidimensional correlations, and other analytical evidence. Calculated shieldings can assist assignments, but their accuracy depends on the electronic-structure method, geometry, treatment of solvent, and conformational averaging.
Historical development and broader usage
Nuclear magnetic resonance was demonstrated in condensed matter in 1946. Chemical shifts became established around 1950, and early high-resolution spectra showed that nuclei in different chemical environments within the same molecule could give distinct resonances. Resolving the different proton environments of ethanol helped demonstrate the structural value of NMR beyond identifying nuclear species.
The term also appears in other spectroscopic contexts. In X-ray photoelectron spectroscopy, a chemical shift is a change in electron binding energy associated with the chemical environment, including oxidation state and bonding. In Mössbauer spectroscopy, the related isomer shift reflects differences in electron density at the nucleus between source and absorber. These effects share the general idea of an environment-dependent spectral displacement, but their physical mechanisms and reference scales differ from those of NMR.