Gas absorption is a separation process in which one or more components of a gas mixture are transferred into the bulk of a liquid. The liquid, called the absorbent or solvent, preferentially takes up the component being removed, called the solute. Absorption is a major unit operation in chemical engineering, used for gas purification, pollution control, product recovery, and the manufacture of chemicals. It may involve physical dissolution alone or dissolution accompanied by chemical reaction.
Scope and related processes
Absorption removes a substance from a gas by incorporating it into a liquid phase. It differs from adsorption, in which substances accumulate at a surface, commonly that of a porous solid. Although industrial equipment can combine several mechanisms, the distinction is important because equilibrium behavior, capacity, and regeneration methods differ.
The reverse of absorption is stripping, or desorption: a dissolved component transfers from a liquid to a gas. Many industrial installations operate an absorber and a separate regenerator as a continuous solvent loop.
Gas scrubbing is a broader equipment and operating term. A wet scrubber may remove gaseous contaminants by absorption, suspended particles by contact with droplets, or both. Absorption also differs from condensation, where cooling or compression produces a liquid phase from vapor without necessarily introducing a separate solvent.
Physical and chemical absorption
Physical absorption
In physical absorption, the solute dissolves without being converted into a chemically distinct species to a significant extent. Its uptake depends on gas–liquid equilibrium, temperature, pressure, and solvent composition.
Examples include water absorption of ammonia and the use of chilled methanol or polyethylene glycol dimethyl ethers to remove acid gases from pressurized process streams. The classification describes the dominant mechanism: real solutions may also exhibit ionization or other chemical interactions.
Physical solvents are particularly useful when the solute has a high partial pressure. Regeneration can often be achieved by reducing pressure, raising temperature, or contacting the liquid with a stripping gas. However, unwanted absorption of valuable gas components can reduce selectivity and increase recovery requirements.
Chemical absorption
In chemical absorption, dissolved solute reacts with one or more liquid-phase components. The reaction reduces the concentration of unreacted solute in the liquid and can therefore increase both absorption capacity and the rate of transfer.
Important examples include:
- Aqueous amines used to remove carbon dioxide and hydrogen sulfide from gases.
- Alkaline solutions used to capture acidic gases such as hydrogen chloride and sulfur dioxide.
- Water absorption of hydrogen chloride to produce hydrochloric acid.
Some reactions are sufficiently reversible for economical solvent regeneration. Others consume the absorbent and produce a salt solution or slurry requiring further processing or disposal. Chemical absorption can be effective at low solute partial pressures, but regeneration, solvent degradation, and corrosion may impose substantial costs.
Thermodynamic basis
Gas–liquid equilibrium
The limiting extent of absorption is determined by thermodynamic equilibrium. For a dilute solute in a suitable liquid, equilibrium can often be approximated by Henry’s law:
where is the equilibrium partial pressure of solute , is its liquid-phase mole fraction, and is a Henry’s-law constant defined on this pressure–mole-fraction basis.
For an approximately ideal gas mixture,
where is the equilibrium gas-phase mole fraction and is total pressure. Henry’s-law constants are also defined using other concentration conventions, sometimes with reciprocal forms, so their definitions and units must accompany numerical values.
At a given liquid composition, absorption occurs when the bulk gas has a solute partial pressure above the equilibrium value associated with that liquid. At equilibrium there is no net transfer.
Increasing total pressure generally increases physical absorption when it raises the solute partial pressure. Increasing temperature often reduces the solubility of gases, although the temperature dependence is system-specific. Reactive solvents require equilibrium models that also account for chemical speciation, reaction equilibria, and nonideal solution behavior.
Heat effects
Dissolution and reaction commonly release heat. The resulting temperature rise can reduce equilibrium uptake and produce a temperature maximum within an absorber. Temperature also changes viscosity, diffusivity, and reaction rates, making its overall effect more complex than a solubility change alone.
An energy balance is therefore often required alongside the separation calculation. Solvent precooling, interstage cooling, and external circulation through a heat exchanger can help control the temperature profile.
Mass-transfer mechanism
Absorption requires transport from the gas bulk to the interface and then into the liquid bulk. Molecular diffusion and fluid motion both contribute.
The classical two-film model represents resistance as concentrated in thin regions on either side of the interface. The interface is usually assumed to be at local equilibrium. With compatible coefficient definitions, the solute molar flux can be written as
where and are gas-side and liquid-side mass-transfer coefficients, is gas-phase partial pressure, and is dissolved concentration. Subscripts and denote bulk conditions and the interface.
An overall expression eliminates the unknown interfacial conditions:
Here is the gas partial pressure in equilibrium with the bulk liquid. For a linear equilibrium relation ,
where is defined on a pressure–concentration basis.
These relations show that a highly soluble gas may be limited mainly by gas-side transport, whereas a sparingly soluble gas often encounters substantial liquid-side resistance. Actual behavior also depends on flow conditions, solvent properties, and reaction kinetics.
A fast liquid-phase reaction can increase uptake by consuming dissolved solute near the interface. This effect is often described by an enhancement factor relative to physical absorption under otherwise comparable conditions. Very rapid reaction does not eliminate all transport limitations: gas-side resistance or transport of the liquid reactant may still control the rate.
Equipment and contacting arrangements
Packed columns
A packed column contains random packing elements or structured packing that provide a large wetted surface. Gas commonly flows upward while liquid flows downward over the packing.
Packed columns can offer low pressure drop and are widely used for gas purification and solvent-based carbon capture. Their performance depends on effective wetting and uniform liquid distribution. Channeling, dry regions, fouling, and poor redistribution can reduce useful contact area.
Tray columns
Tray columns bring gas and liquid into repeated contact on perforated trays or related internals. Gas passes through liquid retained on each tray, while liquid flows between trays through downcomers.
They can be represented as a series of contacting stages. An ideal equilibrium stage corresponds to a theoretical plate, although real trays generally do not reach full equilibrium. Tray efficiency, entrainment, weeping, and downcomer capacity affect performance.
Other contactors
Spray towers, bubble columns, stirred vessels, venturi scrubbers, and membrane contactors are also used.
- Spray towers create liquid droplets in a gas stream and offer relatively open flow passages.
- Bubble columns disperse gas through a continuous liquid phase.
- Stirred vessels provide controlled mixing and are useful for reactive absorption.
- Venturi scrubbers use high gas velocity to generate intensive droplet contact, often combining gas absorption with particle removal.
- Membrane contactors maintain a gas–liquid interface at membrane pores without dispersing one phase into the other. Membrane wetting and added transport resistance can limit performance.
Countercurrent contacting generally provides a favorable driving-force profile because the cleanest solvent contacts the most depleted gas. Cocurrent and crossflow arrangements are used when equipment layout, heat effects, or operating requirements favor them.
Design and performance
Material balance and solvent circulation
A material balance relates the solute removed from the gas to the increase in solvent loading. For a dilute system with approximately constant solute-free carrier-gas and solvent flow rates,
where and are solute-free molar flow rates, and and are solute-to-carrier and solute-to-solvent molar ratios.
The operating relation and equilibrium curve determine the available driving force. At the minimum solvent rate, a pinch occurs where this driving force approaches zero. In the idealized design model, reaching the target separation at that limiting flow requires indefinitely large contacting equipment. Practical solvent rates exceed the minimum.
For dilute systems with a linear equilibrium relation , an absorption factor is often defined as
using consistent molar flow and composition bases. It helps characterize staged absorption, but is not a universal design rule for reactive, concentrated, or strongly nonisothermal systems.
Column height and diameter
Column height supplies the contacting capacity needed to achieve the specified removal. Packed-column calculations often use the height-of-a-transfer-unit and number-of-transfer-units formulation:
where is packed height, is an overall gas-phase transfer-unit height, and represents the required separation expressed through its driving-force integral. This simple product applies when a representative transfer-unit height can be used; detailed models allow properties and coefficients to vary along the column.
Diameter is governed largely by hydraulic capacity. Excessive gas flow can impede downward liquid flow and cause flooding, sharply increasing pressure drop and entrainment. Insufficient liquid flow can leave packing poorly wetted. Design therefore balances mass-transfer performance, stable operation, pressure drop, and cost.
Solvent selection
Important solvent properties include:
- Solubility and selectivity for the target component.
- Useful capacity between regenerated and loaded states.
- Absorption and regeneration kinetics.
- Vapor pressure and solvent carryover.
- Viscosity, diffusivity, and foaming tendency.
- Chemical stability and compatibility with equipment materials.
- Regeneration energy, makeup requirements, and waste generation.
High equilibrium capacity alone does not guarantee an effective process. A solvent can have favorable uptake but poor cyclic performance because it is difficult to regenerate or transfers mass slowly.
Solvent regeneration and process integration
In a regenerative system, loaded or rich solvent leaves the absorber and is treated to release the absorbed material. Regenerated or lean solvent then returns to the absorber.
Regeneration may use pressure reduction, heating, stripping steam, an inert gas, or combinations of these methods. A common amine process includes an absorber, a rich–lean heat exchanger, a regeneration column, a reboiler, and overhead cooling. Heat exchange between hot lean solvent and cooler rich solvent reduces external energy demand.
Pressure reduction is particularly useful for physical solvents operating at elevated pressure. Reactive solvents often require thermal regeneration, although the appropriate method depends on reaction reversibility and solvent chemistry.
The released gas may be recovered as a product, sent for further treatment, or prepared for transport and storage. Absorption by itself transfers a substance between phases; it does not necessarily destroy it or provide permanent disposal.
Industrial applications and development
Gas absorption developed alongside industrial gas washing, acid manufacture, and chemical recovery, and became a standard unit operation as quantitative equilibrium and transport models matured.
Major applications include:
- Natural-gas treatment: removal of carbon dioxide and hydrogen sulfide from natural gas.
- Carbon capture: separation of carbon dioxide from flue gas and process streams for carbon capture systems.
- Chemical manufacture: absorption of hydrogen chloride, ammonia, and other gases into liquids to produce solutions or intermediates.
- Air-pollution control: removal of soluble or reactive gaseous contaminants from industrial exhaust.
- Product recovery: recovery of valuable vapors from gas streams when a suitable selective solvent is available.
- Gas dehydration: absorption of water vapor into hygroscopic liquids such as triethylene glycol.
Absorption also forms part of absorption refrigeration, where uptake of refrigerant vapor into a liquid enables a thermally driven refrigeration cycle rather than primarily serving gas purification.
Limitations and operational concerns
Absorption performance is constrained by equilibrium, transfer rates, and equipment hydraulics. Very low target concentrations can require large contacting areas, highly regenerated solvent, or more reactive absorbents. Compressing a low-pressure gas solely to improve absorption may consume more energy than the resulting separation benefit justifies.
Operating problems include foaming, entrainment, flooding, packing fouling, solvent evaporation, and degradation. Reactive solutions can be corrosive, and impurities may accumulate or form unwanted by-products. Solvent management, emissions control, and materials selection are therefore integral to process safety and environmental performance.
Process control commonly regulates gas and solvent flow, liquid levels, pressure, solvent temperature, and regeneration heat input. Changes in feed composition can affect both removal efficiency and heat release. For integrated facilities, absorption must also be coordinated with upstream contaminant removal and downstream solvent, product, or waste treatment.