Thermal resistance is a measure of how strongly a material, interface, component, or assembly opposes the transfer of heat. For a specified heat-flow path, it is defined as the difference in temperature between two locations divided by the heat-transfer rate between them. It provides a practical way to describe insulation and cooling systems and to calculate temperatures using networks analogous to electrical circuits. Unlike thermal conductivity, thermal resistance generally depends on geometry and boundary conditions as well as material properties.
Definition and units
For heat flowing from a hot location at temperature to a colder location at , the thermal resistance is
where is the heat-transfer rate, measured in watts. Thus,
In the International System of Units, thermal resistance is expressed in kelvins per watt, . Degrees Celsius per watt gives the same numerical value because temperature differences of one degree Celsius and one kelvin are equal.
The reciprocal quantity is thermal conductance:
with units of .
Thermal resistance usually describes steady-state conditions: temperatures remain constant while heat continues to flow. A steady state is not thermodynamic equilibrium, because a temperature difference and sustained heat transfer can remain present.
For linear heat-transfer processes, thermal resistance is independent of the applied temperature difference. When properties or heat-transfer mechanisms vary with temperature, a resistance calculated from a finite temperature difference is an effective value for those operating conditions. An incremental resistance, , need not equal that finite-difference value.
Conduction resistance
Plane layers
Heat conduction is described macroscopically by Fourier’s law. For one-dimensional, steady conduction through a uniform plane layer,
so that
Here is the layer thickness, is the cross-sectional area perpendicular to heat flow, and is the thermal conductivity.
This expression assumes constant conductivity, negligible heat generation within the layer, and negligible edge effects. It shows that:
- Increasing thickness increases resistance.
- Increasing heat-flow area decreases resistance.
- Increasing thermal conductivity decreases resistance.
For example, a layer with , , and has
A temperature difference of would therefore produce a heat-transfer rate of through that layer alone.
Cylindrical and spherical layers
The plane-layer formula cannot be used directly when the heat-flow area changes substantially along the path. For radial conduction through a cylindrical shell,
where and are the inner and outer radii and is the cylinder length. End effects are neglected.
For radial conduction through a spherical shell,
These expressions are used for insulated pipes, vessels, and other curved structures.
Temperature-dependent and directional conductivity
If conductivity varies with temperature, steady one-dimensional conduction through a plane layer instead satisfies
The resulting effective resistance depends on the temperature range.
In anisotropic materials, conductivity depends on direction. Layered composites and graphite, for example, can conduct heat very differently along and across their internal structures. A scalar resistance can still describe a specified path, but complex geometries may require a multidimensional temperature-field calculation.
Convection and radiation resistance
Thermal-resistance methods are not restricted to conduction.
Convection
For heat transfer between a surface and a fluid, convection is commonly represented by
giving
Here is the surface temperature, is a representative bulk-fluid temperature, and is the convective heat-transfer coefficient.
The coefficient is not a material constant. It depends on fluid properties, geometry, flow speed, orientation, and whether flow is natural or forced, laminar or turbulent. The boundary layer next to a surface often plays an important role. A resistance calculated for one airflow condition cannot automatically be used for another.
Thermal radiation
Thermal radiation is intrinsically nonlinear in temperature. For an idealized gray surface exchanging radiation with a large isothermal enclosure,
where is emissivity, is the Stefan–Boltzmann constant, and temperatures are absolute.
Factoring the temperature difference gives
and hence
This form resembles convection resistance, but changes with temperature. Exchanges among multiple finite surfaces also depend on geometry and surface properties; a single surface-to-surroundings resistance may then be inadequate. The underlying temperature dependence follows the theory of blackbody radiation.
When convection and radiation carry heat from a surface to surroundings at the same temperature, they act as parallel paths and their conductances add. If the fluid and radiative surroundings have different temperatures, they must be represented by separate temperature nodes.
Resistance networks
The analogy with electrical resistance associates temperature difference with voltage difference and heat-transfer rate with electric current. The relation has the same algebraic form as Ohm’s law.
Series paths
For elements in series, the same heat-transfer rate passes through each element under steady conditions without intermediate heat generation or branching:
A composite wall can therefore be represented as
The temperature drop across each element is . The largest resistance accounts for the largest temperature drop and often dominates the total resistance.
Parallel paths
When several paths connect the same two temperature nodes,
Metal fasteners through insulation, for example, can provide low-resistance parallel paths. Such paths are called thermal bridges. Even a relatively small conductive path can materially increase heat transfer through an otherwise well-insulated assembly.
Network methods require meaningful node temperatures. Treating a surface as a single node assumes that its temperature is approximately uniform. Strong lateral gradients, local heat sources, or complicated branching may require a more detailed network or a numerical field model.
Contact, boundary, and spreading resistance
Contact resistance
Two solid surfaces in contact do not ordinarily meet across their entire apparent area. Microscopic roughness creates discrete contact spots separated by gaps. Heat must pass through those spots and through any intervening gas or other material, producing thermal contact resistance.
An interface can be described by
where is the contact conductance per unit area.
Contact resistance depends on surface roughness, contact pressure, material properties, cleanliness, and any interface material. Thermal greases, pads, and compliant layers can reduce resistance by replacing poorly conducting voids, although they introduce their own conduction resistance.
At small scales, an interfacial temperature jump can also arise from imperfect transmission of energy carriers, including phonons and electrons, between different materials. This thermal boundary resistance is distinct from resistance caused solely by macroscopic gaps.
Spreading and constriction resistance
When heat passes from a small source into a larger body, heat-flow lines spread outward. Conversely, they converge when heat enters a smaller contact. These multidimensional effects produce spreading or constriction resistance.
A highly conductive plate can consequently have appreciable resistance between a small heat source and a large cooling surface. The simple expression generally does not describe this geometry adequately.
Area-normalized resistance and building R-values
Two related quantities must be distinguished:
- Thermal resistance, , in , describes a specified component or heat-flow path.
- Area-normalized thermal resistance, often written , describes temperature difference divided by heat flux:
For uniform transfer over a specified area,
Its SI unit is , and for a uniform plane layer,
The R-value used in building insulation commonly means this area-normalized quantity, not resistance in . In customary US units it is expressed in , with
The overall heat-transfer coefficient, or U-value, is the reciprocal of the total area-normalized resistance when the same reference area and boundary temperatures are used:
A product’s insulation R-value is not necessarily the R-value of a complete wall or roof. Framing, joints, surface heat transfer, moisture, installation details, and air leakage can change whole-assembly performance. Air leakage transports energy by bulk airflow and is not fully characterized by the conduction resistance of the insulation.
Thermal resistivity, , is another distinct quantity. Its units are ; unlike component resistance, it characterizes a material under specified conditions.
Transient thermal behavior
Thermal resistance describes heat transfer, whereas heat capacity describes energy storage. Both are needed when temperatures change with time.
For a body that can be approximated as having a uniform temperature , connected through a resistance to surroundings at ,
where is the body’s heat capacity and is its internal heating power.
For constant properties, this single-node model has a time constant
More complex systems require multiple resistances and heat capacities. In electronics, transient thermal impedance commonly denotes the temperature response to a specified power input as a function of time. It approaches a steady-state thermal resistance only when the system reaches a steady state under unchanged boundary conditions.
Applications and measurement
High resistance is useful in building insulation, furnace linings, cryogenic vessels, and insulated storage. Low resistance is useful in heat sinks, electronic packaging, cooling equipment, and heat exchangers.
For a semiconductor device under suitable steady conditions, a simple thermal model gives
where is junction temperature, is ambient temperature, and is dissipated power. Junction-to-ambient resistance depends strongly on the circuit board, enclosure, mounting, and airflow; it is not solely an intrinsic property of the semiconductor package. Package thermal metrics also differ in their definitions and test conditions and are not all interchangeable series resistances.
Thermal resistance can be measured by establishing known boundary conditions, supplying or measuring heat flow, and measuring the corresponding temperature difference. Methods include guarded hot-plate and heat-flow-meter measurements for insulation, component heating tests, and interface measurements under controlled mechanical loading.
Important sources of measurement uncertainty include parasitic heat losses, sensor placement, imperfect contacts, incomplete steady state, and nonuniform surface temperatures. A measured resistance is therefore meaningful only when the specimen geometry, temperature locations, operating conditions, and included heat-flow paths are specified.