The standard hydrogen electrode (SHE) is a reference electrode whose standard electrode potential is assigned the value of exactly zero volts at every temperature by convention. It is based on the reversible interconversion of aqueous hydrogen ions and gaseous hydrogen at a platinum surface. The SHE establishes the reference scale for standard electrode potentials in electrochemistry, allowing the relative tendencies of chemical species to undergo reduction or oxidation to be compared.

Electrode reaction and construction

The electrode reaction, written as a reduction, is

2H+(aq)+2e−⇌H2(g).2\mathrm{H^+(aq)}+2e^-\rightleftharpoons\mathrm{H_2(g)}.

Here, H+(aq)\mathrm{H^+(aq)} denotes solvated hydrogen ions; it does not imply that bare protons exist independently in water. The reaction can proceed in either direction, so a hydrogen electrode can function as an anode or a cathode depending on the other half-cell with which it is paired.

A typical physical hydrogen electrode consists of:

  • a platinum foil or wire in contact with an acidic aqueous solution;
  • a finely divided platinum coating, called platinum black, that provides a large active surface;
  • a supply of sufficiently pure hydrogen gas;
  • an electrical connection and an ionic connection to another half-cell.

Platinum conducts electrons and catalyzes the hydrogen reaction without appearing in the net reaction. Its effectiveness depends on catalysis and the adsorption of hydrogen-containing species at its surface.

The idealized half-cell is commonly represented as

Pt(s) ∣ H2(g) ∣ H+(aq).\mathrm{Pt(s)\,|\,H_2(g)\,|\,H^+(aq)}.

A hydrogen electrode operated under arbitrary conditions is not necessarily a standard hydrogen electrode. The term standard specifies the thermodynamic conditions defining its reference potential.

Standard conditions

The SHE is defined by the following conditions:

  1. The activity of aqueous hydrogen ions is unity:

    aH+=1.a_{\mathrm{H^+}}=1.
  2. Hydrogen gas has unit activity relative to its standard gas state:

    fH2p∘=1,\frac{f_{\mathrm{H_2}}}{p^\circ}=1,

    where fH2f_{\mathrm{H_2}} is its fugacity and the standard pressure is

    p∘=1 bar=100 000 Pa.p^\circ=1\ \mathrm{bar}=100\,000\ \mathrm{Pa}.
  3. The electrode is at equilibrium with the solution and gas at a specified temperature.

For nearly ideal hydrogen gas near ambient pressure, fugacity is approximately equal to hydrogen partial pressure. Precision work distinguishes hydrogen partial pressure from total gas pressure, including the contribution of water vapor.

Unit hydrogen-ion activity is not equivalent to a hydrogen-ion concentration of exactly one mole per litre. Activity accounts for nonideal behavior through an activity coefficient. On a molality-based standard-state convention, for example,

aH+=γH+mH+m∘,a_{\mathrm{H^+}} = \gamma_{\mathrm{H^+}}\frac{m_{\mathrm{H^+}}}{m^\circ},

where m∘=1 mol kg−1m^\circ=1\ \mathrm{mol\,kg^{-1}}. An acid solution with a nominal concentration of one mole per litre need not satisfy this condition.

The SHE is often discussed at 298.15 K298.15\ \mathrm{K}, or 25 ∘C25\,^\circ\mathrm{C}, because many tables use that temperature. However, this temperature is not part of the general definition. Its assigned standard potential is zero at every temperature; the standard potentials of other electrodes relative to it generally change with temperature.

Potential and the Nernst equation

For the hydrogen reduction reaction, the Nernst equation gives

E=E∘−RT2Fln⁡[fH2/p∘aH+2],E = E^\circ - \frac{RT}{2F} \ln\left[ \frac{f_{\mathrm{H_2}}/p^\circ} {a_{\mathrm{H^+}}^2} \right],

where RR is the gas constant, TT is absolute temperature, and FF is the Faraday constant. On the SHE scale,

E∘=0.E^\circ=0.

Consequently,

E=RTFln⁡aH+−RT2Fln⁡(fH2p∘).E = \frac{RT}{F}\ln a_{\mathrm{H^+}} - \frac{RT}{2F}\ln\left(\frac{f_{\mathrm{H_2}}}{p^\circ}\right).

At unit hydrogen gas activity, using the definition

pH=−log⁡10aH+,\mathrm{pH}=-\log_{10}a_{\mathrm{H^+}},

the potential becomes

E=−2.303RTF pH.E=-\frac{2.303RT}{F}\,\mathrm{pH}.

At 298.15 K298.15\ \mathrm{K}, this is approximately

E=−(0.05916 V) pH.E=-(0.05916\ \mathrm{V})\,\mathrm{pH}.

Thus, a hydrogen electrode in a solution of pH 7 has a potential of approximately −0.414 V-0.414\ \mathrm{V} versus SHE at this temperature and unit hydrogen gas activity. This is a nonstandard hydrogen electrode potential, not a change in the assigned zero of the SHE.

Why the zero is conventional

A voltmeter measures a potential difference between terminals; it does not directly measure an isolated electrode–solution interfacial potential. In an electrochemical cell, the observable voltage depends on the two electrode systems and, where present, liquid-junction contributions.

Assigning zero to the SHE provides a common reference. It does not mean that the platinum–solution interface has no electric field, charge separation, or interfacial potential difference.

For a cell written with the SHE on the left and another electrode on the right, the standard cell voltage is

Ecell∘=Eright∘−ESHE∘=Eright∘.E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{right}} - E^\circ_{\mathrm{SHE}} = E^\circ_{\mathrm{right}}.

The sign of the other electrode’s standard reduction potential therefore indicates its reduction tendency relative to the standard hydrogen couple.

A separate concept, the absolute electrode potential, relates an electrode potential to an external reference such as an electron in vacuum. It is not identical to the conventional SHE scale.

Uses in thermodynamics and measurement

Standard electrode potentials

Tables of standard reduction potentials normally use the SHE as their reference. Combining two tabulated reduction potentials gives the standard cell potential:

Ecell∘=Ecathode∘−Eanode∘.E^\circ_{\mathrm{cell}} = E^\circ_{\mathrm{cathode}} - E^\circ_{\mathrm{anode}}.

For a reaction transferring nn electrons, the standard Gibbs energy change is

ΔrG∘=−nFEcell∘.\Delta_{\mathrm r}G^\circ=-nFE^\circ_{\mathrm{cell}}.

Its relationship to the dimensionless equilibrium constant is

ln⁡K=nFEcell∘RT.\ln K=\frac{nFE^\circ_{\mathrm{cell}}}{RT}.

These equations connect electrode-potential measurements with the thermodynamics of oxidation–reduction reactions. A favorable cell voltage does not, by itself, establish that a reaction proceeds rapidly: reaction rates also depend on chemical kinetics and electrode-surface processes.

Reference-electrode calibration

The SHE is the fundamental reference scale, but routine laboratories usually use more convenient reference electrodes, such as silver–silver chloride electrodes. Their potentials are related to the SHE scale under specified temperature and electrolyte conditions.

Reliable conversion between reference scales requires the actual reference-electrode potential, not merely the electrode’s name. Electrolyte composition, temperature, and liquid-junction potentials can all affect the conversion.

Acidity measurements

Hydrogen electrodes are important in the foundations of pH measurement. Cells without liquid junctions, including the Harned cell, are used in primary pH measurement procedures.

An important qualification is that the activity of a single ionic species cannot be determined independently by ordinary thermodynamic measurements without an additional convention. Practical pH standards therefore combine cell measurements with agreed conventions concerning single-ion activities. This limits how literally an ideal unit-activity hydrogen electrode can be realized experimentally.

SHE, NHE, and RHE

Three related terms are often encountered:

Term Meaning
Standard hydrogen electrode (SHE) The thermodynamic reference defined by unit hydrogen-ion activity and unit hydrogen gas activity.
Normal hydrogen electrode (NHE) A historical term commonly associated with a hydrogen electrode in a solution of unit normal acid concentration. It is also sometimes used loosely as a synonym for SHE.
Reversible hydrogen electrode (RHE) A hydrogen electrode in equilibrium with the electrolyte being studied; its potential relative to SHE follows that electrolyte’s pH.

NHE and SHE should not automatically be treated as rigorously identical, because concentration and activity are not interchangeable.

The reversible hydrogen electrode is particularly useful for studying hydrogen evolution, oxygen evolution, and other proton-coupled electrode reactions. At unit hydrogen gas activity, a potential reported versus RHE converts to the SHE scale according to

Evs SHE=Evs RHE−2.303RTF pH.E_{\mathrm{vs\,SHE}} = E_{\mathrm{vs\,RHE}} - \frac{2.303RT}{F}\,\mathrm{pH}.

This expression assumes the same temperature and the applicable equilibrium hydrogen-electrode response.

Practical limitations

The SHE is experimentally demanding. Important sources of deviation include:

  • Surface contamination: adsorbed impurities can inhibit the platinum-catalyzed hydrogen reaction.
  • Gas impurities: oxygen or other reactive contaminants can introduce competing reactions and mixed potentials.
  • Pressure errors: hydrogen fugacity may differ from the assumed value.
  • Nonideal solution behavior: nominal acid concentration does not directly establish hydrogen-ion activity.
  • Liquid-junction potentials: contact between solutions of different composition can add an unwanted potential difference.
  • Current flow: appreciable current can shift the electrode away from equilibrium through polarization and concentration changes.

Potential measurements are therefore made under conditions approaching zero current, with controlled gas composition, temperature, solution composition, and surface condition. These demands explain why the SHE remains the defining reference while more convenient secondary electrodes are used for most routine measurements.