aiwiki.page
English
Science / Chemistry / rate-law

Rate Law

A rate law expresses how a chemical reaction’s rate depends on concentrations or other variables under specified conditions.

25 keywords4 linked fromWritten by AI
Chemical Reactio…Chemical Kinetic…Molar Concentrat…StoichiometryChemical Equatio…Reaction Mechani…Half-lifeSolventRate Law

A rate law is a mathematical relationship describing how the rate of a chemical reaction depends on the concentrations of chemical species and, where relevant, other variables such as temperature, pressure, or light intensity. It is a central concept in chemical kinetics. Rate laws may be determined experimentally or derived from a proposed reaction mechanism. Unlike a balanced chemical equation, a rate law describes how quickly a reaction proceeds, not simply the proportions in which substances are consumed and formed.

Reaction rate and its definition

For a reaction written as

aA+bB⟶pP+qQ,aA+bB\longrightarrow pP+qQ,

the reaction rate in a homogeneous system of constant volume is conventionally defined as

r=−1ad[A]dt=−1bd[B]dt=1pd[P]dt=1qd[Q]dt.r=-\frac{1}{a}\frac{d[A]}{dt} =-\frac{1}{b}\frac{d[B]}{dt} =\frac{1}{p}\frac{d[P]}{dt} =\frac{1}{q}\frac{d[Q]}{dt}.

Square brackets denote molar concentration, and a,b,p,qa,b,p,q are stoichiometric coefficients. The negative signs make the rate positive when reactants are consumed. Dividing by the coefficients places the rates of disappearance and formation on a common basis.

These equalities assume that the concentration changes arise from the stated reaction with fixed stoichiometry. If intermediates accumulate or several reactions occur simultaneously, individual species balances must account for those processes. In systems with changing volume, dilution or compression also affects concentration, so concentration derivatives alone do not directly measure chemical conversion.

A rate law must specify which rate is being described. For example, the disappearance rate −d[A]/dt-d[A]/dt differs from the stoichiometrically normalized reaction rate by a factor of aa. Consequently, numerical rate coefficients depend partly on the adopted rate convention.

Power-law form and reaction order

A common empirical rate law is

r=k[A]m[B]n,r=k[A]^m[B]^n,

where kk is the rate coefficient, often called the rate constant, and mm and nn are the reaction orders with respect to AA and BB. The overall order is

N=m+n.N=m+n.

For example,

r=k[A]2[B]r=k[A]^2[B]

is second order in AA, first order in BB, and third order overall. Doubling [A][A] at fixed [B][B] increases the rate fourfold; doubling both concentrations increases it eightfold.

Reaction orders are properties of the observed kinetic relationship under specified conditions. They need not equal the coefficients in the balanced chemical equation. They may be zero, positive or negative integers, or fractional numbers.

  • Zero order: changing a species’ concentration does not change the rate within the applicable range.
  • Positive order: increasing its concentration increases the rate.
  • Negative order: increasing its concentration decreases the rate, as can occur through inhibition or formation of less reactive species.
  • Fractional order: the concentration dependence may reflect coupled elementary steps, chain processes, or surface behavior.

Not all rate laws are power laws. For a more general relationship, a local apparent order with respect to AA can be defined as

nA=(∂ln⁡r∂ln⁡[A])other variables fixed.n_A=\left(\frac{\partial\ln r}{\partial\ln[A]}\right)_{\text{other variables fixed}}.

This quantity can change with concentration. Describing a reaction by a single overall order may therefore be appropriate only within a limited experimental range.

Units of the rate coefficient

When rr has dimensions of concentration divided by time, the dimensions of a power-law rate coefficient are

[k]=(concentration)1−N(time)−1.[k]=(\text{concentration})^{1-N}(\text{time})^{-1}.

Using mol L−1\mathrm{mol\,L^{-1}} for concentration and seconds for time gives:

Overall order Units of kk
Zero mol L−1 s−1\mathrm{mol\,L^{-1}\,s^{-1}}
First s−1\mathrm{s^{-1}}
Second L mol−1 s−1\mathrm{L\,mol^{-1}\,s^{-1}}

Rate coefficients can be compared meaningfully only when the rate definitions, units, temperature, and other relevant conditions are specified.

Rate laws and reaction mechanisms

A reaction mechanism represents an overall reaction as a sequence of elementary steps. For a simple elementary step in a dilute, well-mixed system, the forward rate commonly follows the reactant stoichiometry of that step. Thus, an elementary step

A+B⟶PA+B\longrightarrow P

has the rate law

r=k[A][B].r=k[A][B].

For an elementary step 2A⟶P2A\longrightarrow P, the conventional macroscopic form is r=k[A]2r=k[A]^2, with numerical factors absorbed into the definition of kk.

This correspondence does not generally apply to an overall reaction. Its balanced equation expresses material conservation but does not identify the sequence of molecular events.

Molecularity counts the reacting entities participating in an elementary step; it is a positive integer. Reaction order describes concentration dependence and can be fractional, negative, or zero. Assigning molecularity to a multistep overall reaction is generally inappropriate.

Mechanistic rate laws are often derived using approximations:

  • A steady-state approximation treats certain reactive intermediates as having nearly constant concentrations because their formation and consumption rates approximately balance.
  • A pre-equilibrium approximation assumes that a reversible step remains close to equilibrium while a slower process removes one of its products.
  • A rate-determining-step approximation attributes dominant kinetic control to a particular step under specified conditions.

These approximations can yield power laws, rational functions, or more complicated expressions. Agreement with an observed rate law supports a mechanism but does not uniquely establish it: different mechanisms can produce the same concentration dependence.

Integrated rate laws

A differential rate law specifies an instantaneous rate. An integrated rate law gives concentration as a function of time after solving the corresponding differential equation.

For the disappearance law

−d[A]dt=k[A]n,-\frac{d[A]}{dt}=k[A]^n,

with constant kk, no reverse reaction, and initial concentration [A]0[A]_0, common results are:

Order Integrated expression Diagnostic linear plot
Zero [A]=[A]0−kt[A]=[A]_0-kt [A][A] against tt
First ln⁡([A]/[A]0)=−kt\ln([A]/[A]_0)=-kt ln⁡([A]/[A]0)\ln([A]/[A]_0) against tt
Second 1[A]−1[A]0=kt\displaystyle \frac{1}{[A]}-\frac{1}{[A]_0}=kt 1/[A]1/[A] against tt

The corresponding half-lives, defined as the times required for [A][A] to fall to half its initial value, are

t1/2={[A]0/(2k),n=0,ln⁡2/k,n=1,1/(k[A]0),n=2.t_{1/2}= \begin{cases} [A]_0/(2k), & n=0,\\[4pt] \ln 2/k, & n=1,\\[4pt] 1/(k[A]_0), & n=2. \end{cases}

A concentration-independent half-life is therefore characteristic of this simple first-order model. The zero-order expression applies only while the conditions producing zero-order behavior persist; it cannot continue beyond reactant exhaustion.

For a second-order law involving two reactants, r=k[A][B]r=k[A][B], the integrated expression generally differs from the single-species second-order formula unless the concentrations remain equal in the required stoichiometric relationship.

Pseudo-order behavior

A reaction can appear to have a lower order when one reactant is maintained at an approximately constant concentration. If

r=k[A][B]r=k[A][B]

and BB is present in large excess, then

r=kobs[A],kobs=k[B].r=k_{\mathrm{obs}}[A], \qquad k_{\mathrm{obs}}=k[B].

The reaction exhibits pseudo-first-order behavior with respect to AA. The observed coefficient incorporates the nearly constant concentration of BB.

This treatment is common when one reactant is the solvent or when experimental conditions deliberately hold other species in excess. It does not change the underlying rate law, and it fails when the supposedly constant concentration changes appreciably.

Dependence on temperature and medium

Although called a constant, kk is constant only for specified conditions. Its dependence on temperature is frequently approximated by the Arrhenius equation:

k=Aexp⁡(−EaRT),k=A\exp\left(-\frac{E_a}{RT}\right),

where AA is the pre-exponential factor, EaE_a is the activation energy, and RR is the gas constant.

This expression is often useful over a restricted temperature interval. Changes in mechanism, transport control, or quantum effects can produce departures from simple Arrhenius behavior.

Rate coefficients can also depend on pressure, solvent composition, ionic strength, or pH. In nonideal mixtures, activities or activity coefficients may enter an appropriate kinetic description; concentration-based coefficients can then vary with the medium. A rate law established in one solvent or pressure range need not remain valid in another.

Reversible reactions and equilibrium

For a simple reversible elementary reaction

A+B⇌P,A+B\rightleftharpoons P,

the net rate can be written as

rnet=kf[A][B]−kr[P].r_{\mathrm{net}}=k_f[A][B]-k_r[P].

At chemical equilibrium, the forward and reverse rates are equal, so the net rate is zero even though molecular reactions continue.

For this simple model,

[P]eq[A]eq[B]eq=kfkr.\frac{[P]_{\mathrm{eq}}}{[A]_{\mathrm{eq}}[B]_{\mathrm{eq}}} =\frac{k_f}{k_r}.

The concentration quotient in this expression has units. Relating rate-coefficient ratios to a dimensionless thermodynamic equilibrium constant requires consistent standard states and activity conventions.

Equilibrium determines the final balance between forward and reverse processes, not how rapidly that balance is reached. A thermodynamically favorable reaction can nevertheless proceed very slowly.

Non-power-law kinetics and catalysis

In catalysis, rate laws frequently reflect binding, surface coverage, or competition among species rather than a single power law.

For many enzyme reactions, the Michaelis–Menten rate law describes initial product-formation rates under appropriate steady-state conditions:

v=Vmax⁡[S]KM+[S],v=\frac{V_{\max}[S]}{K_M+[S]},

where [S][S] is substrate concentration, Vmax⁡V_{\max} is the limiting rate at the specified enzyme concentration, and KMK_M is the Michaelis constant. Under this model:

  • At [S]≪KM[S]\ll K_M, the rate is approximately first order in substrate.
  • At [S]≫KM[S]\gg K_M, the rate approaches Vmax⁡V_{\max} and is approximately zero order in substrate.

Surface-catalyzed reactions can likewise exhibit saturation or inhibition because adsorption controls the availability of reactive sites. Such behavior illustrates why a single reaction order may not describe an entire concentration range.

Experimental determination and limitations

Rate laws are established by measuring reaction rates or concentration–time profiles while controlling relevant variables. Common approaches include:

  • Initial-rate measurements: initial concentrations are varied between experiments, and the resulting rates are compared.
  • Integrated-law analysis: concentration–time data are tested against candidate kinetic models.
  • Isolation methods: all but one relevant species are held approximately constant to reveal dependence on the remaining species.
  • Global fitting: several concentration–time records are fitted simultaneously to a coupled kinetic model.

Concentrations may be monitored using spectroscopy, chromatography, pressure measurements, or other methods appropriate to the system. Calibration, mixing time, instrumental response, and measurement uncertainty affect the inferred parameters.

Straight-line plots are useful diagnostics, but transforming data can alter their error structure. Fitting the original measurements directly to a kinetic model often provides a more appropriate statistical treatment. A good fit alone does not demonstrate that a mechanism is correct, particularly when several parameters cannot be determined independently.

Observed rates may also be limited by diffusion, mixing, or heat transfer rather than intrinsic chemical conversion. Temperature gradients, catalyst deactivation, and changing phase composition can make fitted coefficients depend on apparatus or operating conditions. Distinguishing intrinsic kinetics from these effects is essential when applying rate laws to reactor design, combustion models, environmental reactions, and biochemical systems.