Kilowatt-hour

The kilowatt-hour is a unit of energy equal to 3.6 million joules, widely used to measure electricity consumption, generation, and storage.

16 keywords1 linked fromWritten by AI
EnergyPower (Physics)JouleElectricityJames WattSecondInternational Sy…IntegralKilowatt-h…

The kilowatt-hour (symbol kWh) is a unit of energy equal to the energy transferred by a power of one kilowatt sustained for one hour. It is exactly equal to 3.6 million joules, or 3.6 megajoules. The kilowatt-hour is widely used in measuring and billing electricity consumption, reporting electricity generation, and describing the energy capacity of storage systems. Despite its name, it measures energy, not power.

Definition and conversion

Power is the rate at which energy is transferred or converted. One watt equals one joule per second, and one kilowatt equals 1,000 watts. Because an hour contains exactly 3,600 seconds,

1 kWh=1,000 W×3,600 s=3,600,000 J=3.6 MJ.1\ \mathrm{kWh} =1{,}000\ \mathrm{W}\times3{,}600\ \mathrm{s} =3{,}600{,}000\ \mathrm{J} =3.6\ \mathrm{MJ}.

These conversion factors are exact; uncertainty in a measured quantity arises from the measurement, not from the conversion.

The joule is the coherent energy unit of the International System of Units (SI). The kilowatt-hour combines an SI multiple of the watt with the hour, a non-SI unit accepted for use with the SI.

Related units used at different scales include:

Unit Equivalent in kilowatt-hours Equivalent in joules
Watt-hour (Wh) 0.001 kWh 3,600 J
Megawatt-hour (MWh) 1,000 kWh 3.6×1093.6\times10^9 J
Gigawatt-hour (GWh) 1,000,000 kWh 3.6×10123.6\times10^{12} J
Terawatt-hour (TWh) 1,000,000,000 kWh 3.6×10153.6\times10^{15} J

The symbol is case-sensitive: k denotes kilo, W denotes watt, and h denotes hour. The notation kW·h also explicitly indicates multiplication. By contrast, kW/h means kilowatts per hour—a rate of change of power—and is not a unit of energy.

Relationship between energy and power

For constant power, energy is calculated as

E=Pt.E=Pt.

With power expressed in kilowatts and time in hours, the result is in kilowatt-hours. Thus, a device drawing a constant 2 kW for three hours uses 6 kWh. A 10 W lamp operating for 100 hours uses 1 kWh.

If power varies over time, energy is the integral of power:

E=∫t1t2P(t) dt.E=\int_{t_1}^{t_2}P(t)\,dt.

Equivalently, energy equals average power multiplied by elapsed time. A device’s rated power therefore does not by itself determine its energy consumption: operating duration, settings, standby consumption, and cycling behavior can all matter.

This distinction also applies to generating facilities. A plant’s rating in megawatts describes its power capacity; its output in megawatt-hours describes energy generated during a specified period. Two plants with the same rated power can produce different amounts of energy because their operating conditions and availability differ.

Electricity metering and billing

An electricity meter accumulates electrical energy transferred over time. In an idealized single-phase circuit, this energy is

E=∫v(t)i(t) dt,E=\int v(t)i(t)\,dt,

where v(t)v(t) is voltage and i(t)i(t) is electric current. The resulting energy in joules can be converted to kilowatt-hours.

For alternating current, voltage and current may differ in phase or contain waveform distortion. Meters recording kWh measure active energy. Apparent energy, expressed in kilovolt-ampere-hours, and reactive energy, commonly expressed in kilovar-hours, are distinct quantities used in electrical engineering and some tariffs.

Under a simple flat-rate tariff, the energy charge is

C=EkWhr,C=E_{\mathrm{kWh}}r,

where rr is the price per kilowatt-hour. An electricity bill may also include fixed charges, taxes, or charges based on maximum demand in kilowatts. Time-varying tariffs can assign different prices to kilowatt-hours consumed at different times. Consequently, equal energy consumption does not necessarily imply equal cost.

Energy storage and thermal uses

For a battery, a rating in kilowatt-hours describes an amount of stored energy, whereas a rating in kilowatts describes charging or discharging power. Ideally, a system supplying 5 kW from 10 kWh of usable energy could operate for two hours. Actual duration depends on factors including conversion losses, operating limits, temperature, and load.

Battery capacity expressed in ampere-hours measures electric charge, not energy. An approximate conversion is

EWh≈VnominalQAh,E_{\mathrm{Wh}}\approx V_{\mathrm{nominal}}Q_{\mathrm{Ah}},

although an accurate energy calculation must account for voltage variation during discharge.

The kilowatt-hour is not restricted to electrical energy. It can also express heat transferred or fuel energy content. When comparing electrical input with thermal output, both the energy form and the measurement boundary must be specified. For example, a heat pump can deliver more than 1 kWh of heat per kilowatt-hour of electrical input because it also transfers heat from its surroundings; this does not violate the first law of thermodynamics.

Interpretation and limitations

A kilowatt-hour specifies an energy quantity, not its source, cost, environmental impact, or usefulness for a particular task. Its associated emissions depend on how the energy is produced and on the accounting boundary used. Energy delivered to a consumer also differs from energy generated upstream because of losses in the electrical grid.

Likewise, equal amounts of electrical energy and low-temperature heat are not interchangeable in their ability to perform work. Comparisons between technologies therefore require information beyond a common kilowatt-hour total, including conversion efficiency, operating conditions, and the form of energy being measured.