Galvanic corrosion is a form of corrosion in which a metal undergoes increased dissolution because it is electrically connected to a more noble metal or another conductive material while both contact a common electrolyte. The less noble material acts as the anode, where oxidation occurs, while the more noble material supports cathodic reduction reactions. This coupling forms an electrochemical cell and can concentrate severe damage on one component even when the other remains largely intact. Although often called bimetallic corrosion, the process can involve nonmetallic conductors, including graphite and electrically conductive carbon-fiber composites.
Conditions and electrochemical mechanism
Three conditions are required for sustained galvanic corrosion:
- Materials or surface regions with different electrochemical behavior.
- An electronically conducting connection between them, whether by direct contact or through another conductor.
- An electrolyte contacting both surfaces and providing an ionic current path.
The electrolyte may be seawater, process fluid, damp soil, or a thin moisture film containing dissolved salts. Simply placing different metals together does not necessarily produce significant galvanic corrosion if the assembly remains dry or the electrical circuit is interrupted.
The process consists of coupled oxidation–reduction reactions. At the anode, a metal dissolves:
The released electrons travel through the conductive connection to the cathode. In many aerated, approximately neutral aqueous environments, the principal cathodic reaction is oxygen reduction:
In acidic environments, hydrogen evolution may instead be important:
Ions move through the electrolyte to maintain charge balance. The anodic metal ions may remain dissolved or form oxides, hydroxides, or other corrosion products.
A metal that becomes the cathode generally experiences reduced anodic dissolution relative to its uncoupled condition. Cathodic reactions can nevertheless cause other damage, such as local alkalinization, coating disbondment, or hydrogen uptake in susceptible materials.
Potential difference and corrosion rate
Before connection, each material establishes its own corrosion potential in the environment. On connection, the potentials and reaction rates shift through electrochemical polarization. Where electrical and solution resistance are small, the coupled surfaces approach a common mixed potential at which total anodic and cathodic currents balance.
The difference between uncoupled corrosion potentials indicates a possible driving force, but it does not by itself determine the corrosion rate. The current also depends on:
- The kinetics of metal dissolution and cathodic reduction.
- The exposed areas of the coupled materials.
- Electrolyte conductivity and the length of the ionic path.
- Oxygen availability and other reactant concentrations.
- Surface films, deposits, and corrosion products.
- Temperature, flow conditions, and pH.
Electrode overpotentials and voltage losses associated with electrical resistance consume the initial driving potential. Consequently, calculating galvanic current by dividing the uncoupled potential difference by solution resistance alone is generally inadequate.
The Nernst equation describes how equilibrium electrode potentials depend on chemical activities. Actual corrosion potentials, however, are normally mixed potentials involving several simultaneous reactions, not equilibrium potentials for a single metal–ion pair.
Relation between current and metal loss
Faraday’s law relates the charge consumed by anodic dissolution to the quantity of metal dissolved:
where is the dissolved mass, is the metal’s molar mass, is the number of electrons transferred per metal atom, is the Faraday constant, and is the current attributable to that dissolution reaction.
The externally measured galvanic current is not always identical to the total dissolution current. Cathodic reactions can continue on the anodic component itself, so current measured between the components may underestimate its total corrosion.
The galvanic series
A galvanic series ranks metals and other conductive materials according to their measured corrosion potentials in a specified environment. Materials toward the active end tend to become anodes when coupled to materials toward the noble end.
In aerated seawater, magnesium, zinc, and many aluminum alloys commonly occupy relatively active positions, while copper alloys, passive stainless steels, titanium, and graphite occupy more noble positions. Such rankings are environment-specific, not universal.
The galvanic series differs from a table of standard electrode potentials. Standard potentials describe defined equilibrium reactions under specified standard conditions; a galvanic series reflects the behavior of actual surfaces in a particular electrolyte.
Passivation is especially important. Stainless steel can behave relatively nobly when protected by its passive surface film but more actively when that film breaks down. Some galvanic series therefore distinguish active and passive states of the same alloy.
Proximity in a galvanic series is a useful screening criterion, but it does not establish a universally safe material combination. Surface condition, geometry, and reaction kinetics remain essential.
Area ratio and localization
One of the strongest geometric influences is the ratio of exposed cathode area to exposed anode area. In simplified form,
where is anodic current density, is the anodic dissolution current, and is the exposed anodic area.
A large cathode connected to a small anode can support a high dissolution current per unit anode area. A small carbon-steel fastener in a large, wetted, passive stainless-steel assembly may therefore suffer rapid attack. The reversed arrangement—a small stainless-steel fastener in a large steel component—is often less severe from the standpoint of galvanic current density, although other corrosion mechanisms may still be important.
The relevant areas are the wetted, electrochemically effective areas, not necessarily the components’ total geometric areas. A remote part of a cathode may contribute little if electrolyte resistance is high. In thin moisture films or poorly conducting water, attack may concentrate near the junction.
This area effect also explains why a small defect in a coating on an anodic metal can be dangerous: the exposed defect may become a tiny anode coupled to a much larger cathodic surface.
Typical occurrences
Marine structures and equipment
Seawater provides an effective ionic path, making galvanic coupling important in ships, offshore structures, heat exchangers, and harbor equipment. Aluminum components coupled to copper alloys or passive stainless steel can experience accelerated attack.
Copper-containing runoff can create an additional problem when dissolved copper deposits onto aluminum or zinc. The resulting copper deposits form local cathodic sites, even without a continuing metallic connection to the original copper component.
Buildings and water systems
Dissimilar-metal joints occur in roofing, cladding, pipework, and fasteners. Their behavior depends on wetting duration, dissolved salts, coatings, and water chemistry. A joint that performs acceptably in a dry interior may deteriorate in a coastal atmosphere or persistently damp location.
Rust or staining at a joint is not, by itself, proof of galvanic corrosion. Crevice conditions and ordinary atmospheric corrosion can produce similar appearances.
Carbon-fiber composites
In electrically conductive carbon-fiber-reinforced polymers, exposed carbon fibers can support cathodic reactions. Aluminum connected to such a composite can become the anode when moisture completes the circuit. Resin-rich surfaces, insulating interlayers, and sealed interfaces can limit coupling, but exposed fibers and conductive fasteners may provide unintended connections.
Microscopic galvanic cells
Related processes occur within alloys when different phases, inclusions, or precipitates have different electrochemical behavior. These are often described as microgalvanic corrosion. External contact between two separate components is therefore not necessary for galvanically driven localized attack.
Prevention and controlled use
Control measures interrupt the circuit, reduce the driving force, or limit the electrochemical reactions.
Material selection. Compatible combinations are selected using galvanic-series data and testing relevant to the actual service environment. A small potential separation alone does not guarantee compatibility.
Electrical isolation. Nonconductive gaskets, sleeves, washers, or interlayers can break the electronic connection. Isolation is ineffective if another fastener, grounding conductor, or structural connection bypasses it.
Electrolyte exclusion. Sealing, drainage, drying, and joint designs that avoid water retention reduce the time during which a conductive liquid path exists.
Coatings. Barrier coatings limit electrolyte access. Coating only the anodic component can create severe localized attack at defects if a large cathode remains exposed. Coating the cathode, or properly protecting both components, can reduce this unfavorable area effect.
Area management. A small exposed anode coupled to a large effective cathode is generally avoided where the environment permits sustained galvanic current.
Cathodic protection. Cathodic protection deliberately makes a structure the cathode. Sacrificial anodes, commonly based on zinc, aluminum, or magnesium alloys, dissolve preferentially to protect the connected structure. Impressed-current systems instead use an external power supply.
Galvanized steel combines a zinc barrier with sacrificial protection: zinc can corrode preferentially and protect exposed steel at limited coating defects. This protection is finite and depends on the environment and the remaining zinc.
The intentional use of galvanic action has a long history. In 1824, Humphry Davy investigated protecting the copper sheathing of ships by coupling it to more active metals, an early application of cathodic protection.
Assessment and distinction from related damage
Investigation combines inspection of attack patterns with identification of materials, electrical connections, wetted areas, electrolyte chemistry, and exposure conditions. Corrosion-potential measurements and coupled-current measurements can help establish whether galvanic action is significant.
Laboratory tests must reproduce relevant area ratios, surface conditions, oxygen supply, temperature, and exposure cycles. Results from continuous immersion may not represent intermittently wet atmospheric joints. Conversely, a low current measured during a dry period does not rule out substantial damage during earlier wet periods.
Galvanic corrosion is distinguished from several related processes:
- Pitting corrosion is highly localized attack associated with breakdown of a protective surface film. Galvanic coupling can promote it, but pitting does not require dissimilar materials.
- Crevice corrosion arises in shielded regions where restricted transport changes the local solution chemistry. It can coexist with galvanic corrosion at joints.
- Stray-current corrosion results from current entering and leaving a structure because of an external electrical source, rather than solely from the natural potential difference between coupled materials.
- Differential-aeration corrosion results from differences in oxygen availability on a surface and can occur on a single metal.
These mechanisms can reinforce one another. A dissimilar-metal fastener may form a crevice, establish an unfavorable cathode-to-anode area ratio, and expose a locally depassivated surface at the same location.