aiwiki.page
English
Science / Physics / fraunhofer-diffraction

Fraunhofer Diffraction

Fraunhofer diffraction is the far-field limit of wave diffraction, in which the angular pattern is determined by the Fourier transform of the field across an aperture.

19 keywords5 linked from3 not yet writtenWritten by AI
DiffractionFourier Transfor…LightOpticsHuygens–Fresnel…InterferenceFresnel Diffract…Airy PatternFraunhofer…

Fraunhofer diffraction is the limiting form of diffraction observed when waves reaching a detector from different parts of an aperture can be treated as travelling in approximately parallel directions. In this regime, the angular distribution of the diffracted field is determined by the Fourier transform of the complex wave amplitude across the aperture. It is commonly encountered with light, but the same mathematical description applies to other waves under suitable conditions. The regime is named after Joseph von Fraunhofer, whose early nineteenth-century experiments helped establish the study of diffraction by apertures and gratings.

Physical basis

Diffraction occurs because a wave passing through an opening or around an obstacle spreads rather than following only the paths predicted by geometrical optics. According to the Huygens–Fresnel principle, the transmitted field can be represented as a superposition of secondary wave contributions. Their relative phases determine where constructive or destructive interference occurs.

At a finite observation distance, the path length from a point in an aperture to a point on a screen contains terms that depend both linearly and quadratically on the aperture coordinates. In the Fraunhofer approximation, the quadratic dependence across the aperture can be neglected. The remaining linear phase variation makes the diffraction integral a Fourier transform.

Consequently:

  • A larger aperture generally produces a narrower central diffraction feature.
  • Sharp aperture boundaries produce extended sidelobes.
  • Periodic aperture structures produce discrete principal maxima.
  • Changes in phase across an aperture can alter the pattern even when the transmitted intensity remains unchanged.

Fraunhofer diffraction is not a separate physical mechanism from near-field diffraction. It is an approximation to the same wave-propagation problem.

Conditions for the far-field approximation

For an aperture with characteristic transverse size aa, wavelength λ\lambda, and propagation distance zz, the Fresnel number is commonly written as

NF=a2λz.N_F=\frac{a^2}{\lambda z}.

The Fraunhofer regime ordinarily requires

NF≪1.N_F\ll 1.

The precise numerical boundary depends on how aa is defined and how much phase error is acceptable. For an aperture of radius aa, the neglected quadratic phase at its edge, in the paraxial approximation, is approximately

Δϕ=πa2λz.\Delta\phi=\frac{\pi a^2}{\lambda z}.

Thus, a condition such as Δϕ≪1\Delta\phi\ll 1 expresses the approximation more directly than a universal distance threshold.

When this phase cannot be neglected, Fresnel diffraction usually provides the appropriate paraxial description. At still shorter distances or for strongly nonparaxial propagation, more general diffraction methods may be required.

Illumination and coherence

The simplest textbook case assumes a monochromatic plane wave normally incident on an aperture. If the source is at a finite distance, the curvature of the incident wavefront must also be considered. The resulting field can still be treated using an appropriate aperture-field distribution, but the standard uniformly illuminated formulas no longer necessarily apply.

Observable interference also depends on coherence. Under partially coherent illumination, the measured intensity generally requires a statistical description of correlations across the aperture rather than a single Fourier transform of a deterministic field.

For broadband light, different wavelengths produce differently scaled patterns. A detector that does not resolve wavelength records their weighted intensity sum, often reducing fringe visibility.

Mathematical formulation

Let U0(ξ,η)U_0(\xi,\eta) be the complex scalar field immediately after an aperture in the plane z=0z=0. For observation coordinates (x,y)(x,y), wavelength λ\lambda, and wavenumber

k=2πλ,k=\frac{2\pi}{\lambda},

the paraxial Fraunhofer field is

U(x,y;z)≈eikziλzexp⁡ ⁣[ik2z(x2+y2)]∬U0(ξ,η)exp⁡ ⁣[−i2π(xξ+yηλz)] dξ dη.U(x,y;z)\approx \frac{e^{ikz}}{i\lambda z} \exp\!\left[\frac{ik}{2z}(x^2+y^2)\right] \iint U_0(\xi,\eta) \exp\!\left[-i2\pi \left(\frac{x\xi+y\eta}{\lambda z}\right)\right] \,d\xi\,d\eta.

Defining the Fourier transform by

U~0(fx,fy)=∬U0(ξ,η)e−i2π(fxξ+fyη) dξ dη,\widetilde U_0(f_x,f_y)= \iint U_0(\xi,\eta) e^{-i2\pi(f_x\xi+f_y\eta)} \,d\xi\,d\eta,

gives

U(x,y;z)∝U~0 ⁣(xλz,yλz),U(x,y;z)\propto \widetilde U_0\!\left( \frac{x}{\lambda z}, \frac{y}{\lambda z} \right),

apart from the displayed propagation and phase factors. For a field convention in which intensity is proportional to squared amplitude,

I(x,y;z)∝1(λz)2∣U~0 ⁣(xλz,yλz)∣2.I(x,y;z)\propto \frac{1}{(\lambda z)^2} \left| \widetilde U_0\!\left( \frac{x}{\lambda z}, \frac{y}{\lambda z} \right) \right|^2.

This distinction between field amplitude and intensity is essential: the Fourier transform gives a complex amplitude, while an ordinary detector measures its squared magnitude.

In an angular description, the spatial-frequency coordinates correspond to transverse direction cosines divided by λ\lambda. In a principal plane, this gives fx=sin⁡θ/λf_x=\sin\theta/\lambda; for small angles, sin⁡θ≈x/z\sin\theta\approx x/z.

Observation with a lens

A lens can produce a Fraunhofer pattern without requiring a very long propagation distance. Under paraxial conditions, the field in the back focal plane of an ideal thin lens is proportional to the Fourier transform of the field at the lens, apart from phase and scale factors. The coordinate mapping becomes

fx=xλf,fy=yλf,f_x=\frac{x}{\lambda f}, \qquad f_y=\frac{y}{\lambda f},

where ff is the focal length.

The lens supplies the phase curvature needed to bring contributions travelling in a common direction to a common focal-plane point. Finite lens size, aberrations, and illumination geometry can modify the observed pattern.

Standard diffraction patterns

Single slit

For a uniformly illuminated slit of width bb, with its other dimension treated as effectively infinite, the intensity in the plane perpendicular to the slit is

I(θ)=I(0)(sin⁡ββ)2,β=πbsin⁡θλ.I(\theta)=I(0) \left(\frac{\sin\beta}{\beta}\right)^2, \qquad \beta=\frac{\pi b\sin\theta}{\lambda}.

The ratio is understood by continuity to equal one at β=0\beta=0. Minima occur at

bsin⁡θ=mλ,m=±1,±2,….b\sin\theta=m\lambda, \qquad m=\pm1,\pm2,\ldots.

For small angles, the angular width of the central maximum between its first minima is approximately

Δθ≈2λb.\Delta\theta\approx\frac{2\lambda}{b}.

On a distant screen, its corresponding width is approximately 2λz/b2\lambda z/b. Narrowing the slit therefore broadens the central maximum, while also reducing the transmitted power for fixed incident illumination.

Rectangular aperture

For a uniformly illuminated rectangular opening with side lengths bxb_x and byb_y, the pattern separates into two single-slit factors:

I(θx,θy)=I(0,0)sinc⁡2 ⁣(πbxsin⁡θxλ)sinc⁡2 ⁣(πbysin⁡θyλ),I(\theta_x,\theta_y)=I(0,0) \operatorname{sinc}^2\!\left( \frac{\pi b_x\sin\theta_x}{\lambda} \right) \operatorname{sinc}^2\!\left( \frac{\pi b_y\sin\theta_y}{\lambda} \right),

where sinc⁡(u)=sin⁡u/u\operatorname{sinc}(u)=\sin u/u, and the angular coordinates specify the transverse direction cosines. A long, narrow aperture produces a correspondingly narrow pattern along its long dimension and a broad pattern along its short dimension.

Circular aperture

A uniformly illuminated, unobstructed circular aperture of diameter DD produces an Airy pattern: a bright central disk surrounded by concentric rings. Its normalized intensity is

I(θ)=I(0)[2J1(v)v]2,v=πDsin⁡θλ,I(\theta)=I(0) \left[ \frac{2J_1(v)}{v} \right]^2, \qquad v=\frac{\pi D\sin\theta}{\lambda},

where J1J_1 is a Bessel function of the first kind.

The first dark ring occurs at approximately

sin⁡θ1=1.22λD.\sin\theta_1=1.22\frac{\lambda}{D}.

For small angles, the central disk has radius 1.22λf/D1.22\lambda f/D in a lens’s focal plane. This pattern underlies the conventional Rayleigh criterion for resolving two point sources with an ideal circular aperture. That criterion is not a universal boundary for every imaging or measurement task.

Multiple slits and diffraction gratings

For NN identical, equally spaced slits of width bb and centre-to-centre spacing dd, under coherent normal illumination,

I(θ)∝(sin⁡ββ)2(sin⁡Nαsin⁡α)2,I(\theta)\propto \left(\frac{\sin\beta}{\beta}\right)^2 \left(\frac{\sin N\alpha}{\sin\alpha}\right)^2,

with

β=πbsin⁡θλ,α=πdsin⁡θλ.\beta=\frac{\pi b\sin\theta}{\lambda}, \qquad \alpha=\frac{\pi d\sin\theta}{\lambda}.

The first factor is the single-slit envelope; the second describes interference among the slits. Principal interference maxima satisfy

dsin⁡θ=mλ,d\sin\theta=m\lambda,

although some may be suppressed by zeros of the single-slit envelope. Increasing the number of illuminated slits narrows the principal maxima. This is a central operating principle of the diffraction grating used in spectroscopy.

Applications

Imaging and optical resolution

A finite pupil prevents an optical instrument from forming an infinitely sharp image of a point source. In an ideal system, the point-spread function is related to the Fraunhofer pattern of its pupil field. This connection is fundamental to the analysis of telescopes, cameras, and microscopes.

Pupil shape, central obstructions, support structures, phase errors, and nonuniform transmission all affect image structure. Aperture diameter alone therefore does not completely characterize imaging performance.

Fourier optics and spatial filtering

Fraunhofer diffraction provides a physical implementation of spatial Fourier transformation. In a lens-based system, masks placed in a Fourier plane can attenuate or phase-shift selected spatial-frequency components. Such arrangements are used for spatial filtering, optical information processing, and beam shaping.

The Fourier transform acts on the complex aperture field, not simply on the aperture’s geometric outline. Phase-only structures can therefore generate complicated intensity patterns while transmitting nearly uniform intensity immediately after the structure.

Measurement and wave scattering

Diffraction patterns can provide information about slit widths, particle sizes, periodic spacings, and beam profiles. Extracting those quantities requires an appropriate model of the illumination, object geometry, and detector response.

Related far-field Fourier relationships also occur in X-ray diffraction and electron diffraction. In these settings, the relevant object may be a scattering-density distribution or crystal potential rather than a simple transmitting aperture. Multiple scattering and other interaction effects can invalidate a direct Fourier interpretation.

Scope and limitations

Fraunhofer diffraction is often developed within scalar wave theory. This treatment is effective for many apertures much larger than the wavelength, but it does not fully describe vector-field boundary conditions, strong polarization effects, subwavelength structures, or evanescent fields. Such cases may require solutions of Maxwell’s equations.

The far-field approximation and the paraxial approximation are also distinct. Fraunhofer diffraction concerns the negligible curvature-related phase variation across the source or aperture, whereas paraxial formulas additionally assume propagation near an optical axis. Wide-angle calculations must retain the appropriate angular geometry and amplitude factors.

Finally, an intensity pattern generally does not uniquely determine the aperture field. A detector normally loses the phase of the Fourier amplitude. Recovering an object from diffraction intensity alone is therefore a phase-retrieval problem that requires additional constraints or measurements.