Fraunhofer diffraction is the limiting form of diffraction observed when waves reaching a detector from different parts of an aperture can be treated as travelling in approximately parallel directions. In this regime, the angular distribution of the diffracted field is determined by the Fourier transform of the complex wave amplitude across the aperture. It is commonly encountered with light, but the same mathematical description applies to other waves under suitable conditions. The regime is named after Joseph von Fraunhofer, whose early nineteenth-century experiments helped establish the study of diffraction by apertures and gratings.
Physical basis
Diffraction occurs because a wave passing through an opening or around an obstacle spreads rather than following only the paths predicted by geometrical optics. According to the Huygens–Fresnel principle, the transmitted field can be represented as a superposition of secondary wave contributions. Their relative phases determine where constructive or destructive interference occurs.
At a finite observation distance, the path length from a point in an aperture to a point on a screen contains terms that depend both linearly and quadratically on the aperture coordinates. In the Fraunhofer approximation, the quadratic dependence across the aperture can be neglected. The remaining linear phase variation makes the diffraction integral a Fourier transform.
Consequently:
- A larger aperture generally produces a narrower central diffraction feature.
- Sharp aperture boundaries produce extended sidelobes.
- Periodic aperture structures produce discrete principal maxima.
- Changes in phase across an aperture can alter the pattern even when the transmitted intensity remains unchanged.
Fraunhofer diffraction is not a separate physical mechanism from near-field diffraction. It is an approximation to the same wave-propagation problem.
Conditions for the far-field approximation
For an aperture with characteristic transverse size , wavelength , and propagation distance , the Fresnel number is commonly written as
The Fraunhofer regime ordinarily requires
The precise numerical boundary depends on how is defined and how much phase error is acceptable. For an aperture of radius , the neglected quadratic phase at its edge, in the paraxial approximation, is approximately
Thus, a condition such as expresses the approximation more directly than a universal distance threshold.
When this phase cannot be neglected, Fresnel diffraction usually provides the appropriate paraxial description. At still shorter distances or for strongly nonparaxial propagation, more general diffraction methods may be required.
Illumination and coherence
The simplest textbook case assumes a monochromatic plane wave normally incident on an aperture. If the source is at a finite distance, the curvature of the incident wavefront must also be considered. The resulting field can still be treated using an appropriate aperture-field distribution, but the standard uniformly illuminated formulas no longer necessarily apply.
Observable interference also depends on coherence. Under partially coherent illumination, the measured intensity generally requires a statistical description of correlations across the aperture rather than a single Fourier transform of a deterministic field.
For broadband light, different wavelengths produce differently scaled patterns. A detector that does not resolve wavelength records their weighted intensity sum, often reducing fringe visibility.
Mathematical formulation
Let be the complex scalar field immediately after an aperture in the plane . For observation coordinates , wavelength , and wavenumber
the paraxial Fraunhofer field is
Defining the Fourier transform by
gives
apart from the displayed propagation and phase factors. For a field convention in which intensity is proportional to squared amplitude,
This distinction between field amplitude and intensity is essential: the Fourier transform gives a complex amplitude, while an ordinary detector measures its squared magnitude.
In an angular description, the spatial-frequency coordinates correspond to transverse direction cosines divided by . In a principal plane, this gives ; for small angles, .
Observation with a lens
A lens can produce a Fraunhofer pattern without requiring a very long propagation distance. Under paraxial conditions, the field in the back focal plane of an ideal thin lens is proportional to the Fourier transform of the field at the lens, apart from phase and scale factors. The coordinate mapping becomes
where is the focal length.
The lens supplies the phase curvature needed to bring contributions travelling in a common direction to a common focal-plane point. Finite lens size, aberrations, and illumination geometry can modify the observed pattern.
Standard diffraction patterns
Single slit
For a uniformly illuminated slit of width , with its other dimension treated as effectively infinite, the intensity in the plane perpendicular to the slit is
The ratio is understood by continuity to equal one at . Minima occur at
For small angles, the angular width of the central maximum between its first minima is approximately
On a distant screen, its corresponding width is approximately . Narrowing the slit therefore broadens the central maximum, while also reducing the transmitted power for fixed incident illumination.
Rectangular aperture
For a uniformly illuminated rectangular opening with side lengths and , the pattern separates into two single-slit factors:
where , and the angular coordinates specify the transverse direction cosines. A long, narrow aperture produces a correspondingly narrow pattern along its long dimension and a broad pattern along its short dimension.
Circular aperture
A uniformly illuminated, unobstructed circular aperture of diameter produces an Airy pattern: a bright central disk surrounded by concentric rings. Its normalized intensity is
where is a Bessel function of the first kind.
The first dark ring occurs at approximately
For small angles, the central disk has radius in a lens’s focal plane. This pattern underlies the conventional Rayleigh criterion for resolving two point sources with an ideal circular aperture. That criterion is not a universal boundary for every imaging or measurement task.
Multiple slits and diffraction gratings
For identical, equally spaced slits of width and centre-to-centre spacing , under coherent normal illumination,
with
The first factor is the single-slit envelope; the second describes interference among the slits. Principal interference maxima satisfy
although some may be suppressed by zeros of the single-slit envelope. Increasing the number of illuminated slits narrows the principal maxima. This is a central operating principle of the diffraction grating used in spectroscopy.
Applications
Imaging and optical resolution
A finite pupil prevents an optical instrument from forming an infinitely sharp image of a point source. In an ideal system, the point-spread function is related to the Fraunhofer pattern of its pupil field. This connection is fundamental to the analysis of telescopes, cameras, and microscopes.
Pupil shape, central obstructions, support structures, phase errors, and nonuniform transmission all affect image structure. Aperture diameter alone therefore does not completely characterize imaging performance.
Fourier optics and spatial filtering
Fraunhofer diffraction provides a physical implementation of spatial Fourier transformation. In a lens-based system, masks placed in a Fourier plane can attenuate or phase-shift selected spatial-frequency components. Such arrangements are used for spatial filtering, optical information processing, and beam shaping.
The Fourier transform acts on the complex aperture field, not simply on the aperture’s geometric outline. Phase-only structures can therefore generate complicated intensity patterns while transmitting nearly uniform intensity immediately after the structure.
Measurement and wave scattering
Diffraction patterns can provide information about slit widths, particle sizes, periodic spacings, and beam profiles. Extracting those quantities requires an appropriate model of the illumination, object geometry, and detector response.
Related far-field Fourier relationships also occur in X-ray diffraction and electron diffraction. In these settings, the relevant object may be a scattering-density distribution or crystal potential rather than a simple transmitting aperture. Multiple scattering and other interaction effects can invalidate a direct Fourier interpretation.
Scope and limitations
Fraunhofer diffraction is often developed within scalar wave theory. This treatment is effective for many apertures much larger than the wavelength, but it does not fully describe vector-field boundary conditions, strong polarization effects, subwavelength structures, or evanescent fields. Such cases may require solutions of Maxwell’s equations.
The far-field approximation and the paraxial approximation are also distinct. Fraunhofer diffraction concerns the negligible curvature-related phase variation across the source or aperture, whereas paraxial formulas additionally assume propagation near an optical axis. Wide-angle calculations must retain the appropriate angular geometry and amplitude factors.
Finally, an intensity pattern generally does not uniquely determine the aperture field. A detector normally loses the phase of the Fourier amplitude. Recovering an object from diffraction intensity alone is therefore a phase-retrieval problem that requires additional constraints or measurements.