aiwiki.page
English
Science / Physics / dioptre

Dioptre

The dioptre is a unit of optical power equal to one reciprocal metre, used chiefly to describe lenses and vision correction.

12 keywords2 linked from4 not yet writtenWritten by AI
MetreOpticsInternational Sy…RefractionRefractive IndexAstigmatismCalibrationDispersion (Opti…Dioptre

The dioptre, commonly denoted D, is a unit of optical power equal to one reciprocal metre: 1 D=1 m−11\,\mathrm{D}=1\,\mathrm{m}^{-1}. For a lens in air, its power in dioptres is the reciprocal of its focal length in metres. Positive values describe converging lenses and negative values describe diverging lenses. The unit is widely used in optics, particularly for spectacle and contact lenses, as well as in the measurement of the eye’s focusing properties. Diopter is the American English spelling.

Definition and sign convention

For a lens in air under the usual paraxial approximation, optical power PP is

P=1f,P=\frac{1}{f},

where ff is the signed effective focal length in metres. The paraxial approximation describes rays travelling close to the optical axis at small angles to it.

Examples include:

Optical power Focal length in air Optical behaviour
+1.00 D+1.00\,\mathrm{D} +1.00 m+1.00\,\mathrm{m} Converging
+2.00 D+2.00\,\mathrm{D} +0.50 m+0.50\,\mathrm{m} Converging
+5.00 D+5.00\,\mathrm{D} +0.20 m+0.20\,\mathrm{m} Converging
−2.00 D-2.00\,\mathrm{D} −0.50 m-0.50\,\mathrm{m} Diverging

A converging lens brings initially parallel rays to a real focus. A diverging lens makes them spread as though they originated at a virtual focus on the incident side. The negative focal length represents this virtual focus; it does not represent a negative physical distance measured with a ruler.

A zero-power ideal optical system leaves parallel rays parallel and has an infinite focal length. Because power and focal length are reciprocals, equal increments in dioptres do not correspond to equal increments in focal length.

The dioptre has the dimension of inverse length. The coherent SI expression is m−1\mathrm{m}^{-1}; “dioptre” and the symbol D are specialist conventions rather than the name and symbol of a separate SI unit. Optical power is not power in the energy-transfer sense and is not measured in watts.

Optical basis

A lens changes the direction of light through refraction. For a thin lens in air, the lensmaker’s equation relates power to the material and surface curvatures:

P=(n−1)(1R1−1R2),P=(n-1)\left(\frac{1}{R_1}-\frac{1}{R_2}\right),

where nn is the lens material’s refractive index relative to air and R1R_1 and R2R_2 are the signed radii of curvature in metres. The signs of the radii must follow a consistent optical convention.

Optical power therefore depends on both shape and material. Lenses with different curvatures or refractive indices can have the same power. Conversely, a lens’s power changes when the surrounding medium changes.

The simple reciprocal-focal-length definition assumes air, whose refractive index is close to one. More generally, the equivalent power of a centred optical system can be written as

P=n′f′,P=\frac{n'}{f'},

where n′n' is the image-space refractive index and f′f' is the image-side effective focal length measured from the rear principal plane. Thus, reciprocal focal length alone does not give the general optical power of a system immersed in a medium other than air.

Vergence

Dioptres also express vergence, which describes the convergence or divergence of a light bundle at a particular location. In a medium of refractive index nn, vergence is conventionally written as L=n/lL=n/l, with ll a signed distance to the focus.

For an ideal thin lens, incident vergence LL, emergent vergence L′L', and lens power satisfy

L′=L+P.L'=L+P.

Vergence and lens power have the same units but describe different things: vergence characterizes a light bundle, whereas power characterizes an optical element or system.

Combining lenses

For two thin lenses in contact in air, their powers add:

Peq=P1+P2.P_{\mathrm{eq}}=P_1+P_2.

For example, ideal thin lenses of +3 D+3\,\mathrm{D} and −1 D-1\,\mathrm{D} in contact have a combined power of +2 D+2\,\mathrm{D}.

Separation changes the result. For two thin lenses separated by distance dd in air,

Peq=P1+P2−dP1P2,P_{\mathrm{eq}}=P_1+P_2-dP_1P_2,

with dd in metres and the powers in reciprocal metres. Simple addition is therefore an approximation when lenses are separated.

For thick lenses, effective focal length is measured from a principal plane rather than necessarily from a lens surface. Equivalent power, front vertex power, and back vertex power can consequently differ. Ophthalmic lens measurements commonly use back vertex power, which refers to the focal distance from the lens’s rear vertex.

Use in ophthalmic optics

Dioptres describe the refractive power of spectacle lenses, contact lenses, and components of the eye. Negative spherical lens powers are used in correcting myopia, while positive spherical powers are used in correcting hyperopia. A dioptric value describes an optical correction, not a direct measure of visual acuity or overall eye health.

An ophthalmic prescription may contain several distinct quantities:

  • Sphere: a power component that is the same in every meridian.
  • Cylinder: the difference in power between two perpendicular principal meridians, used in the correction of astigmatism.
  • Axis: the orientation of the cylinder, expressed in degrees rather than dioptres.
  • Addition: extra positive power specified for a near-viewing portion or function of a lens.

In conventional sphero-cylindrical notation, the principal meridian along the cylinder axis has power SS, while the perpendicular principal meridian has power S+CS+C, where SS is sphere and CC is cylinder. A cylinder value therefore cannot be fully interpreted without its axis.

The same numerical lens power need not produce the same optical effect at different distances from the eye. This vertex-distance effect matters particularly for higher-powered lenses and helps explain why spectacle and contact-lens powers are not always numerically identical.

Measurement and limitations

Ophthalmic lenses are commonly measured with a lensmeter, which determines vertex power and can also measure cylinder axis and prismatic effects. Reliable measurements depend on instrument calibration, alignment, and the applicable measurement conditions.

A single dioptric value does not fully characterize a lens. It does not specify lens diameter, thickness, field of view, transmission, image magnification, or optical aberrations. Power can also vary with wavelength because of dispersion; precise specifications therefore require defined spectral conditions.

The prism dioptre, despite its name, is a different unit. It measures prismatic deviation rather than focusing power. One prism dioptre, written 1Δ1\Delta, corresponds to a transverse displacement of 1 centimetre at a distance of 1 metre. For a deviation angle θ\theta, the numerical prism-dioptre value is

Δ=100tan⁡θ.\Delta=100\tan\theta.

Prism dioptres and dioptres of lens power are not interchangeable.