The candela, symbol cd, is the base unit of luminous intensity in the International System of Units (SI). It measures the amount of visible light emitted in a particular direction per unit solid angle, weighted according to a standardized model of human visual sensitivity. Unlike a measurement of total radiant power, luminous intensity accounts for the fact that different wavelengths of light produce different visual responses. The candela is defined by fixing the luminous efficacy of monochromatic radiation at a specified frequency to an exact numerical value.

Definition

The SI defines the candela by taking the fixed numerical value of the luminous efficacy of monochromatic radiation of frequency 540×1012540\times10^{12} hertz to be 683 when expressed in lumens per watt:

Kcd=683 lm W−1=683 cd sr W−1.K_{\mathrm{cd}} = 683\ \mathrm{lm\,W^{-1}} = 683\ \mathrm{cd\,sr\,W^{-1}}.

Here, lm denotes the lumen, sr the steradian, and W the watt. The defining frequency corresponds to green light with a vacuum wavelength of approximately 555.17 nanometres, calculated using the speed of light.

Equivalently, a source emitting monochromatic radiation at that frequency has a luminous intensity of one candela in a given direction if its radiant intensity in that direction is

Ie=1683 W sr−1.I_{\mathrm e} = \frac{1}{683}\ \mathrm{W\,sr^{-1}}.

This is approximately 1.464 milliwatts per steradian. It is radiant power per unit solid angle, not the source’s total power.

The candela is one of the seven SI base units. Its present definition is part of the system of definitions based on fixed values of constants that took effect on 20 May 2019. The defining value is exact; practical measurements that realize the unit still have measurement uncertainty.

Luminous intensity and solid angle

Luminous intensity describes how a source distributes its luminous output by direction. It is defined as

Iv=dΦvdΩ,I_{\mathrm v} = \frac{\mathrm d\Phi_{\mathrm v}}{\mathrm d\Omega},

where IvI_{\mathrm v} is luminous intensity, Φv\Phi_{\mathrm v} is luminous flux, and Ω\Omega is solid angle. Consequently,

1 cd=1 lm sr−1.1\ \mathrm{cd} = 1\ \mathrm{lm\,sr^{-1}}.

A steradian is the solid angle subtended at the centre of a sphere by a patch of surface whose area equals the square of the sphere’s radius. A complete sphere contains 4π4\pi steradians.

For an ideal source emitting equally in every direction, luminous intensity and total luminous flux are related by

Φv=4πIv.\Phi_{\mathrm v}=4\pi I_{\mathrm v}.

Thus, an isotropic source with an intensity of one candela emits 4π4\pi lumens, approximately 12.57 lumens.

Real sources are often strongly directional. Two lamps can emit the same total luminous flux while having very different intensities along their beam axes. Concentrating a given flux into a narrower beam increases its intensity within that beam without necessarily increasing the total emitted flux.

Although the steradian is dimensionless in SI dimensional analysis, its name and symbol are retained to distinguish angular quantities and make photometric relationships explicit.

Connection with human vision

Photometry measures light using standardized visual weighting, whereas radiometry measures electromagnetic radiation in physical quantities such as radiant power and radiant intensity.

Under bright, or photopic, viewing conditions, the standard spectral luminous efficiency function V(λ)V(\lambda) describes the relative sensitivity of human vision to different wavelengths. It is greatest in the green region of the spectrum and much smaller near the violet and deep-red ends. Equal radiant intensities at different wavelengths therefore generally correspond to unequal luminous intensities.

For radiation with a continuous spectrum, photopic luminous intensity is calculated from spectral radiant intensity:

Iv=Km∫0∞Ie,λ(λ)V(λ) dλ,I_{\mathrm v} = K_{\mathrm m} \int_0^\infty I_{\mathrm e,\lambda}(\lambda) V(\lambda)\,\mathrm d\lambda,

where:

  • Ie,λI_{\mathrm e,\lambda} is radiant intensity per unit wavelength;
  • V(λ)V(\lambda) is the standard photopic spectral luminous efficiency function, normalized to a maximum of one;
  • KmK_{\mathrm m} is the maximum photopic luminous efficacy, approximately 683 lm W−1683\ \mathrm{lm\,W^{-1}}.

The exact defining value of KcdK_{\mathrm{cd}} applies at the specified frequency of 540 terahertz. The distinction between that value and the maximum of a wavelength-based efficiency function is very small but matters in precise formulations.

Standard photometric weighting represents an agreed reference observer, not every individual’s visual response. At low light levels, rod-mediated vision has a different spectral sensitivity. Intermediate adaptation conditions also require different treatment. Consequently, equal candela values do not guarantee equal apparent brightness under all viewing conditions.

Relationship to other lighting quantities

Several quantities used in lighting describe different aspects of the same optical system:

Quantity Meaning SI unit
Luminous intensity Luminous flux per solid angle in a specified direction candela, cd
Luminous flux Total visually weighted radiant output lumen, lm
Illuminance Luminous flux incident per unit area lux, lx
Luminance Luminous intensity per projected emitting or reflecting area candela per square metre, cd/m²

For a sufficiently small source illuminating a surface perpendicular to the incoming light, illuminance is approximately

Ev=Ivr2,E_{\mathrm v}=\frac{I_{\mathrm v}}{r^2},

where rr is the distance from the source. A one-candela source therefore produces one lux at one metre under these idealized conditions. For oblique incidence on a surface, a cosine factor is included. These relationships assume negligible attenuation and a geometry in which the source can be treated as a point.

Luminance describes the directional output per projected area of an extended source. It is commonly used for displays, illuminated surfaces, and glare assessment. The informal display unit nit means one candela per square metre, not one candela.

Historical development

Early luminous-intensity standards used specified candles and flame lamps. Their reproducibility was limited by fuel composition, wick characteristics, combustion conditions, and the surrounding atmosphere. The name candela comes from the Latin word for candle, but an ordinary candle is not a defining standard.

During the twentieth century, a more reproducible standard was developed using a cavity radiator at the freezing temperature of platinum. This connected the unit to blackbody radiation rather than to the variable output of a flame.

In 1948, the General Conference on Weights and Measures adopted the name candela for the new unit. A revised wording adopted in 1967 defined it through the intensity emitted perpendicular to a specified area of a blackbody at the freezing temperature of platinum.

In 1979, the definition changed to monochromatic radiation at 540 terahertz with radiant intensity 1/683 W sr−11/683\ \mathrm{W\,sr^{-1}}. This removed the requirement to realize the unit using a high-temperature platinum-based source.

The 2019 SI revision expressed the definition by fixing KcdK_{\mathrm{cd}}. It preserved the size of the unit and the physical basis of the 1979 definition.

Realization and measurement

In metrology, realizing the candela means establishing a practical measurement consistent with its definition. Modern methods commonly connect photometric measurements to calibrated radiometric detectors.

A detector-based realization may use an optical power standard, a photodiode with known spectral responsivity, and a filter designed to approximate the standard visual weighting function. Precision apertures and measured distances establish the geometry needed to relate received optical power to luminous intensity.

Important sources of uncertainty include:

  • imperfect matching between the detector’s spectral response and V(λ)V(\lambda);
  • uncertainty in the source spectrum;
  • aperture area, distance, and alignment errors;
  • stray light and unwanted reflections;
  • source instability and detector nonlinearity.

Calibration transfers the unit from primary standards to working instruments and reference lamps. Metrological traceability establishes a documented chain of calibrations, each contributing to the uncertainty of the final measurement.

Applications and interpretation

Candela measurements are used for vehicle lamps, signalling lights, aviation lighting, directional luminaires, and light-emitting diodes. Their angular intensity distributions describe where light is sent, information that total luminous flux alone cannot provide.

A candela rating must therefore be interpreted with its direction and measurement conditions. A high peak intensity may describe a narrow beam rather than a large total light output. For extended sources, luminance may be more relevant to appearance; for light arriving on a surface, illuminance is the appropriate quantity.

The candela is not a measure of electrical consumption, total emitted energy, colour quality, or optical safety. Those properties require additional measurements beyond standard visual weighting.