Ampere-hour

The ampere-hour is a unit of electric charge equal to 3,600 coulombs, widely used to express battery capacity under specified operating conditions.

18 keywords2 linked fromWritten by AI
Electric ChargeElectric CurrentAmpereCoulombBatterySecondInternational Sy…TemperatureAmpere-hou…

The ampere-hour (symbol Ah, also written A·h) is a unit of electric charge equal to the charge transferred by a steady electric current of one ampere flowing for one hour. It is exactly equal to 3,600 coulombs. Its principal use is to express the charge capacity of a battery: the quantity of charge that the battery can deliver under specified discharge conditions. Despite its association with stored electricity, the ampere-hour is not a unit of energy.

Definition and notation

Electric charge transferred through a circuit is the time integral of current:

Q=∫t0t1I(t) dt.Q=\int_{t_0}^{t_1} I(t)\,\mathrm{d}t.

For constant current, this becomes Q=ItQ=It. When current is expressed in amperes and time in hours, the resulting charge is expressed in ampere-hours. Because one hour is exactly 3,600 seconds,

1 Ah=3,600 A s=3,600 C.1\ \mathrm{Ah}=3{,}600\ \mathrm{A\,s}=3{,}600\ \mathrm{C}.

The coulomb is the coherent unit of charge in the International System of Units (SI). The ampere-hour is a noncoherent unit formed by combining an SI unit with the hour, a non-SI unit accepted for use with the SI.

Common multiples and submultiples include:

Unit Symbol Equivalent charge
Microampere-hour μAh 0.0036 C0.0036\ \mathrm{C}
Milliampere-hour mAh 3.6 C3.6\ \mathrm{C}
Ampere-hour Ah 3,600 C3{,}600\ \mathrm{C}
Kiloampere-hour kAh 3.6×106 C3.6\times10^6\ \mathrm{C}

The symbol Ah denotes a product, not a quotient. A/h, meaning amperes per hour, instead describes a rate of change of current. Unit symbols are case-sensitive: the ampere symbol is uppercase A, while the hour symbol is lowercase h.

Use in battery capacity ratings

A battery’s ampere-hour rating describes how much charge it can deliver before reaching a specified discharge endpoint. For example, a nominal capacity of 2 Ah corresponds to 7,200 C of delivered charge under the relevant test conditions.

In an idealized calculation, a 2 Ah battery could supply 2 A for one hour, 1 A for two hours, or 0.1 A for twenty hours. Actual batteries do not necessarily deliver the same capacity at all three discharge rates. A meaningful capacity rating therefore depends on conditions including:

  • Discharge current or load profile.
  • Initial state of charge and charging procedure.
  • Operating temperature.
  • End-of-discharge voltage.
  • Battery age and previous use.

The rating measures charge transferred through the external circuit during electrochemical reactions. It does not mean that the battery contains an equivalent net excess electric charge; batteries normally remain approximately electrically neutral overall.

Battery capacity in ampere-hours is also distinct from capacitance, which is charge change per unit voltage change and is measured in farads.

Discharge rate and runtime

Battery currents are often described using the C-rate, which expresses current relative to a reference ampere-hour capacity. For a battery rated at 5 Ah:

  • A 1C rate corresponds to 5 A.
  • A 0.2C rate corresponds to 1 A.
  • A 2C rate corresponds to 10 A.

A 1C discharge would last one hour only if the full reference capacity were available at that rate. Runtime may be shorter because of voltage limits, internal losses, or rate-dependent electrochemical behavior.

For a constant-current load, a first approximation to runtime is

t≈QusableI,t\approx\frac{Q_{\mathrm{usable}}}{I},

with tt in hours when usable capacity is in ampere-hours and current is in amperes. For constant-power equipment, current typically rises as battery voltage falls, so a fixed-current calculation may be inadequate.

In lead–acid batteries, available capacity commonly decreases as discharge current increases, a behavior often approximated by Peukert’s law over a limited operating range. Other chemistries also exhibit rate-dependent capacity, but their behavior need not follow the same relationship.

Relationship to energy

Ampere-hours measure charge, whereas energy depends on both charge and voltage. For a battery discharging through an external circuit, the electrical energy delivered is

E=∫V(t)I(t) dt.E=\int V(t)I(t)\,\mathrm{d}t.

Here V(t)V(t) is the terminal potential difference. With voltage in volts, current in amperes, and time in seconds, the result is in joules. If time is measured in hours, the corresponding result is in watt-hours.

Using a representative voltage gives the approximation

EWh≈VnominalQAh.E_{\mathrm{Wh}}\approx V_{\mathrm{nominal}}Q_{\mathrm{Ah}}.

Thus, a 3 Ah battery with a nominal voltage of 3.7 V has a nominal energy of approximately 11.1 Wh. A 3 Ah battery rated at 12 V has approximately 36 Wh. Equal ampere-hour ratings therefore do not imply equal energy storage.

Actual delivered energy depends on the discharge voltage curve and the operating conditions. In devices containing voltage converters, such as power banks, an ampere-hour rating at the internal battery voltage cannot be directly treated as the available ampere-hours at the output voltage. Voltage conversion and conversion losses must both be considered.

Series and parallel connections

For identical, balanced electrochemical cells operated within their limits:

  • Series connection adds the cell voltages while leaving the ampere-hour capacity approximately equal to that of one cell.
  • Parallel connection adds the ampere-hour capacities while maintaining approximately the voltage of one cell.

For example, two 3.7 V, 2 Ah cells connected in series form a nominal 7.4 V, 2 Ah battery. Connected in parallel, they form a nominal 3.7 V, 4 Ah battery. Both arrangements have approximately the same nominal energy, 14.8 Wh.

These relationships assume compatible cells. Differences in capacity, internal resistance, temperature, or state of charge can limit the usable capacity of a real battery pack.

Measurement and other applications

Battery capacity is commonly measured by charging according to a defined procedure, discharging to a specified voltage limit, and integrating the measured current over time. The result depends on the test protocol as well as the battery itself. Instrument calibration, current-sensor error, timing accuracy, and endpoint detection contribute to measurement uncertainty.

Battery-management systems also integrate current in a process called coulomb counting to estimate changes in state of charge. Such estimates can drift because of measurement offsets, self-discharge, and changes in usable capacity as a battery ages.

Outside battery testing, ampere-hours can express the charge passed during electrolysis and electroplating. Through the Faraday constant, transferred charge can be related to the amount of substance electrochemically transformed, provided the reaction stoichiometry and current efficiency are known. Charge efficiency and energy efficiency remain distinct: recovering most of the input ampere-hours does not necessarily mean recovering the same proportion of the input energy.