{
  "id": "stokes-parameters",
  "title": "Stokes Parameters",
  "lang": "en",
  "source_lang": "en",
  "summary": "Stokes parameters are four real quantities that describe the intensity and polarization of electromagnetic radiation, including partially polarized light.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Stokes polarization parameters",
    "Stokes vector components"
  ],
  "generated_at": "2026-11-06",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/stokes-parameters/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/stokes-parameters/",
      "json": "https://aiwiki.page/zh/stokes-parameters.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "The Stokes parameters are four real quantities that describe the intensity and polarization state of a transverse beam of electromagnetic radiation. Usually written as \\(I,Q,U,V\\), or equivalently \\(S_0,S_1,S_2,S_3\\), they characterize total intensity, two components of linear polarization, and circular polarization. Unlike a description based on a single pair of electric-field amplitudes, they accommodate fully polarized, partially polarized, and unpolarized radiation. They are widely used in optics, remote sensing, and astronomy because they can be determined from intensity measurements."
    },
    {
      "heading": "Historical background",
      "text": "George Gabriel Stokes introduced the four quantities in 1852 in his analysis of streams of polarized light. Their central advantage was the ability to describe mixtures of polarized and unpolarized radiation without following the rapid oscillations of the electromagnetic field.\n\nThe parameters later became the basis of the Stokes–Mueller formalism, which describes how optical systems transform polarization. Their statistical interpretation is closely related to the coherence matrix of classical optics and to the density matrix used in quantum theory."
    },
    {
      "heading": "Definition and conventions",
      "text": "Consider radiation propagating in a specified direction, with orthogonal transverse axes \\(x\\) and \\(y\\). Let \\(E_x\\) and \\(E_y\\) be the complex amplitudes of the transverse electric field, using a time dependence \\(e^{-i\\omega t}\\). For a narrowband field, define\n\n\\[\\begin{aligned} I &= \\left\\langle |E_x|^2+|E_y|^2\\right\\rangle,\\\\ Q &= \\left\\langle |E_x|^2-|E_y|^2\\right\\rangle,\\\\ U &= 2\\operatorname{Re}\\left\\langle E_xE_y^*\\right\\rangle,\\\\ V &= -2\\operatorname{Im}\\left\\langle E_xE_y^*\\right\\rangle. \\end{aligned}\\]\n\nHere, the asterisk denotes complex conjugation, and angle brackets denote a suitable time or ensemble average. A common physical proportionality factor has been suppressed. With that factor included, the parameters have intensity units; in astronomical work they may instead be expressed as spectral radiance, flux density, or related quantities.\n\nThe parameters form the Stokes vector\n\n\\[\\mathbf S= \\begin{pmatrix} I\\\\Q\\\\U\\\\V \\end{pmatrix}.\\]\n\nTheir meanings are:\n\nParameter | Meaning\n\\(I\\) | Total intensity\n\\(Q\\) | Intensity difference between linear polarization along \\(x\\) and along \\(y\\)\n\\(U\\) | Intensity difference between linear polarization at \\(+45^\\circ\\) and \\(-45^\\circ\\) to \\(x\\)\n\\(V\\) | Intensity difference between two orthogonal circular polarization states\n\nThe sign of \\(V\\) is not universal. Different disciplines and instruments use different definitions of circular handedness, viewing direction, and complex time dependence. Under the explicit convention above, a field proportional to \\((1,i)\\) has positive \\(V\\). Calling this state “right-circular” or “left-circular” requires a further convention.\n\nThe signs of \\(Q\\) and \\(U\\) likewise depend on the orientation of the transverse reference axes. Stokes measurements must therefore specify both a coordinate frame and a circular-polarization convention."
    },
    {
      "heading": "Physical interpretation",
      "text": "Linear, circular, and elliptical polarization\n\nFor a fully polarized field written as\n\n\\[E_x=a,\\qquad E_y=b e^{i\\delta},\\]\n\nwith \\(a,b\\geq0\\), the parameters are\n\n\\[\\begin{aligned} I &= a^2+b^2,\\\\ Q &= a^2-b^2,\\\\ U &= 2ab\\cos\\delta,\\\\ V &= 2ab\\sin\\delta. \\end{aligned}\\]\n\nThus \\(Q\\) measures the imbalance between orthogonal linear components, while \\(U\\) and \\(V\\) encode their relative phase as well as their amplitudes.\n\nSome representative states are:\n\nPolarization state | Normalized Stokes vector \\((I,Q,U,V)/I\\)\nLinear along \\(x\\) | \\((1,1,0,0)\\)\nLinear along \\(y\\) | \\((1,-1,0,0)\\)\nLinear at \\(+45^\\circ\\) | \\((1,0,1,0)\\)\nLinear at \\(-45^\\circ\\) | \\((1,0,-1,0)\\)\nCircular with positive \\(V\\) | \\((1,0,0,1)\\)\nCircular with negative \\(V\\) | \\((1,0,0,-1)\\)\nUnpolarized | \\((1,0,0,0)\\)\n\nA general fully polarized state is elliptically polarized: at a fixed point, the electric-field vector traces an ellipse over an optical cycle.\n\nDegree of polarization\n\nPhysically admissible Stokes parameters satisfy\n\n\\[I\\geq0,\\qquad Q^2+U^2+V^2\\leq I^2.\\]\n\nFor \\(I>0\\), the degree of polarization is\n\n\\[P=\\frac{\\sqrt{Q^2+U^2+V^2}}{I}.\\]\n\nIt distinguishes three cases:\n\n- Fully polarized: \\(P=1\\).\n- Partially polarized: \\(0<P<1\\).\n- Unpolarized: \\(P=0\\), so \\(Q=U=V=0\\).\n\nThe degree of linear polarization and the signed circular polarization fraction are\n\n\\[P_{\\mathrm L}=\\frac{\\sqrt{Q^2+U^2}}{I}, \\qquad p_{\\mathrm C}=\\frac{V}{I}.\\]\n\nThe magnitude \\(|V|/I\\) is the unsigned degree of circular polarization.\n\nAn unpolarized beam does not lack an electric field. Rather, its averaged transverse correlations have no preferred polarization. The result depends on the temporal, spatial, and spectral averaging used in the measurement.\n\nEvery nonzero Stokes vector admits a unique decomposition, at the level of these second-order statistics, into an unpolarized contribution and a fully polarized contribution. Writing\n\n\\[R=\\sqrt{Q^2+U^2+V^2},\\]\n\ngives\n\n\\[\\mathbf S= \\begin{pmatrix} I-R\\\\0\\\\0\\\\0 \\end{pmatrix} + \\begin{pmatrix} R\\\\Q\\\\U\\\\V \\end{pmatrix}.\\]\n\nThis mathematical decomposition does not identify a unique microscopic mixture of source fields."
    },
    {
      "heading": "Polarization ellipse and Poincaré sphere",
      "text": "For fully polarized radiation, let \\(\\psi\\) be the orientation of the polarization ellipse and \\(\\chi\\) its signed ellipticity angle. Then\n\n\\[\\begin{aligned} Q &= I\\cos(2\\chi)\\cos(2\\psi),\\\\ U &= I\\cos(2\\chi)\\sin(2\\psi),\\\\ V &= I\\sin(2\\chi). \\end{aligned}\\]\n\nThe range \\(-\\pi/4\\leq\\chi\\leq\\pi/4\\) includes linear polarization at \\(\\chi=0\\) and circular polarization at the endpoints. The minor-to-major axis ratio is \\(|\\tan\\chi|\\). When the linear component is nonzero,\n\n\\[\\psi=\\frac12\\operatorname{atan2}(U,Q),\\]\n\nwith orientation understood modulo \\(\\pi\\). For circular polarization, the ellipse orientation is undefined. For partially polarized radiation, ellipse parameters describe its fully polarized component, not the entire fluctuating field.\n\nThe normalized parameters\n\n\\[q=Q/I,\\qquad u=U/I,\\qquad v=V/I\\]\n\nprovide coordinates in the Poincaré sphere representation. Fully polarized states lie on the unit sphere, partially polarized states lie inside it, and unpolarized radiation lies at its center. Linear polarization occupies the equator, while the circular states occupy opposite poles.\n\nOpposite points on the surface represent orthogonal polarization states. The doubled angles reflect the fact that rotating a linear polarization direction through \\(180^\\circ\\) restores the same state."
    },
    {
      "heading": "Coherence matrix and Jones calculus",
      "text": "The transverse coherence, or coherency, matrix is\n\n\\[J= \\begin{pmatrix} \\langle |E_x|^2\\rangle & \\langle E_xE_y^*\\rangle\\\\ \\langle E_yE_x^*\\rangle & \\langle |E_y|^2\\rangle \\end{pmatrix} = \\frac12 \\begin{pmatrix} I+Q & U-iV\\\\ U+iV & I-Q \\end{pmatrix}.\\]\n\nIt is Hermitian and positive semidefinite. Its eigenvalues are\n\n\\[\\lambda_\\pm=\\frac12\\left(I\\pm\\sqrt{Q^2+U^2+V^2}\\right).\\]\n\nTheir nonnegativity yields the physical constraint on the Stokes parameters.\n\nA fully polarized nonzero state has a rank-one coherence matrix and can be represented by a Jones vector, a two-component complex field amplitude. An unpolarized state has \\(J=(I/2)\\mathbb 1_2\\), where \\(\\mathbb 1_2\\) is the two-dimensional identity matrix.\n\nJones vectors retain complex amplitude information but, individually, describe only fully polarized states. Stokes vectors and coherence matrices also describe statistical mixtures. They do not retain a common optical phase: multiplying both field components by the same phase factor leaves all four Stokes parameters unchanged. Consequently, Stokes vectors alone generally do not determine the interference of mutually coherent beams; their relative phase and cross-correlations are also required.\n\nIn quantum mechanics, \\(J/I\\) has the mathematical form of a two-state density matrix. With the usual Pauli matrices,\n\n\\[\\frac{J}{I} =\\frac12\\left(\\mathbb 1_2+u\\sigma_x+v\\sigma_y+q\\sigma_z\\right).\\]\n\nThis connects the Poincaré sphere to the Bloch-sphere representation of a two-level quantum system."
    },
    {
      "heading": "Transformations of Stokes parameters",
      "text": "Rotation of reference axes\n\nIf the transverse axes are rotated through an angle \\(\\theta\\), with\n\n\\[E_{x'}=E_x\\cos\\theta+E_y\\sin\\theta,\\]\n\nthe Stokes parameters transform as\n\n\\[\\begin{aligned} I' &= I,\\\\ Q' &= Q\\cos2\\theta+U\\sin2\\theta,\\\\ U' &= -Q\\sin2\\theta+U\\cos2\\theta,\\\\ V' &= V. \\end{aligned}\\]\n\nThus \\(Q\\) and \\(U\\) depend on the chosen axes, whereas \\(I\\), \\(V\\), and the total degree of polarization are invariant under this rotation.\n\nMueller matrices\n\nAn optical element or propagation system can often be represented by a real \\(4\\times4\\) Mueller matrix:\n\n\\[\\mathbf S_{\\mathrm{out}}=M\\mathbf S_{\\mathrm{in}}.\\]\n\nThis formalism describes polarizers, retarders, reflection, scattering, and depolarizing systems. A deterministic Jones transformation \\(A\\) acts on the coherence matrix as\n\n\\[J_{\\mathrm{out}}=A J_{\\mathrm{in}}A^\\dagger\\]\n\nand induces a corresponding Mueller transformation. Depolarizing Mueller matrices require a more general description than a single Jones matrix, such as an ensemble of unresolved transformations.\n\nAn ideal lossless retarder rotates the polarization vector \\((Q,U,V)\\) on the Poincaré sphere while preserving \\(I\\) and \\(P\\). A depolarizer can reduce \\(P\\), whereas a polarizer can increase it by selectively transmitting particular polarization components. Not every arbitrary real \\(4\\times4\\) matrix represents a physically realizable optical system."
    },
    {
      "heading": "Measurement",
      "text": "The experimental determination of Stokes parameters is called polarimetry. For ideal, consistently calibrated analyzer measurements,\n\n\\[\\begin{aligned} I &= I_x+I_y,\\\\ Q &= I_x-I_y,\\\\ U &= I_{+45^\\circ}-I_{-45^\\circ},\\\\ V &= I_+-I_-, \\end{aligned}\\]\n\nwhere \\(I_+\\) and \\(I_-\\) are intensities in circular analyzer states defined consistently with the chosen sign convention.\n\nA linear analyzer at angle \\(\\alpha\\) transmits\n\n\\[I_\\alpha= \\frac12\\left(I+Q\\cos2\\alpha+U\\sin2\\alpha\\right).\\]\n\nThis expression contains no \\(V\\), so rotating a linear polarizer alone cannot determine circular polarization. A phase-sensitive optical element, such as a quarter-wave plate, can convert circular polarization into a measurable linear component. Retarders commonly exploit birefringence.\n\nAt least four linearly independent intensity measurements are needed to recover four unrestricted Stokes parameters. Practical instruments often use additional measurements to improve noise performance or suppress systematic errors. Calibration must account for detector gain differences, imperfect retardance, instrumental polarization, and cross-talk between parameters.\n\nBecause \\(P\\) and \\(P_{\\mathrm L}\\) involve nonnegative square roots of squared noisy measurements, their direct estimates are biased upward at low signal-to-noise ratio. Noise can also produce reconstructed vectors outside the physical region. Statistical estimation may therefore incorporate physical constraints and a measurement-noise model."
    },
    {
      "heading": "Applications and limitations",
      "text": "In astronomy, Stokes measurements constrain radiation mechanisms and the geometry of magnetic fields. Synchrotron radiation can exhibit strong linear polarization, while circular polarization and polarized spectral lines provide additional diagnostics. Polarization can also change during propagation, so observed parameters reflect both emission and intervening material.\n\nIn atmospheric and planetary remote sensing, polarization provides information about scattering, aerosols, clouds, and surface properties. Polarized radiative transfer treats intensity and polarization together, generally evolving a Stokes vector rather than a single scalar intensity.\n\nIn optical engineering, the parameters characterize sources, fibers, coatings, displays, and imaging systems. Combined with suitable models, they help distinguish selective absorption, phase retardation, and depolarization.\n\nThe four parameters completely specify the local second-order polarization statistics of a transverse field under the stated averaging conditions. They do not specify its full spectrum, absolute phase, higher-order fluctuations, or correlations between different positions and times. A single four-component vector is also insufficient for a general three-dimensional field with an appreciable longitudinal electric component.\n\nDepolarization is resolution-dependent. Unresolved mixtures of individually fully polarized fields can yield a partially polarized or unpolarized measurement. Spatial, temporal, or spectral integration can therefore change the measured degree of polarization even when each resolved contribution is fully polarized."
    }
  ],
  "links": [
    "polarization",
    "electromagnetic-radiation",
    "optics",
    "astronomy",
    "density-matrix",
    "electric-field",
    "interference",
    "quantum-mechanics",
    "birefringence",
    "calibration",
    "magnetic-field",
    "synchrotron-radiation",
    "scattering",
    "radiative-transfer"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}