  "id": "stator",
  "title": "Stator",
  "lang": "en",
  "source_lang": "en",
  "summary": "A stator is the stationary part of a rotating machine, providing electromagnetic interaction in electrical machines or directing fluid flow in turbomachinery.",
  "category": "technology",
  "subcategory": "engineering",
  "type": "concept",
  "aliases": [],
  "generated_at": "2026-11-04",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/stator/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/stator/",
      "json": "https://aiwiki.page/zh/stator.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "A stator is the stationary part of a rotating machine, distinguished from the moving rotor. In an electric motor or electric generator, it forms part of the electromagnetic system that converts electrical energy into mechanical energy or vice versa. In turbomachinery, it consists of stationary blades, vanes, or passages that guide fluid toward or away from rotating components. “Stationary” normally means fixed relative to the machine’s housing, even when the whole machine is moving, as in a vehicle."
    },
    {
      "heading": "Stators in electrical machines",
      "text": "An electrical-machine stator typically includes a magnetic core, electrical windings or permanent magnets, insulation, and a supporting structure. Its precise function depends on the machine design: it may produce the main magnetic field, carry the windings in which voltage is induced, or provide a magnetic path for fields generated elsewhere.\n\nIn a conventional radial-flux machine, the stator surrounds the rotor, with a narrow air gap between them. This arrangement is not universal. An external-rotor machine has its rotor outside the stator, while an axial-flux machine has disk-shaped active components separated by an axial gap. Thus, a stator is defined by its lack of rotation rather than by its position on the outside of a machine.\n\nThe stator also transmits reaction torque to the housing and mounting structure. Although it remains stationary, it must withstand electromagnetic forces, vibration, thermal expansion, and, under fault conditions, potentially large mechanical loads."
    },
    {
      "heading": "Electromagnetic operation",
      "text": "Alternating-current motors\n\nIn many alternating-current motors, stator windings are distributed around the air gap. A balanced three-phase supply produces currents displaced in time; combined with the spatial arrangement of the windings, these create a rotating magnetic field.\n\nThe synchronous speed of this field is\n\n\\[n_s=\\frac{120f}{P},\\]\n\nwhere \\(n_s\\) is the speed in revolutions per minute, \\(f\\) is the electrical frequency in hertz, and \\(P\\) is the total number of magnetic poles.\n\nIn an induction motor, the stator field induces currents in the rotor. Their interaction with the magnetic field produces torque. During ordinary steady-state motoring operation, the rotor runs below synchronous speed; the difference is described by slip.\n\nIn a synchronous motor, the rotor turns at the speed of the rotating stator field during steady synchronous operation. Rotor excitation may come from permanent magnets or an energized field winding; reluctance-based designs instead exploit differences in magnetic reluctance.\n\nA variable-frequency drive changes the supply frequency and voltage to control motor operation. Consequently, the stator’s magnetic design, insulation, and cooling must suit not only the mechanical load but also the electrical waveform supplied by the drive.\n\nGenerators and direct-current machines\n\nIn many synchronous generators, the stator carries the armature winding, in which the output voltage is induced, while the rotor supplies the main magnetic field. Keeping the output winding stationary simplifies insulation, cooling, and connection to the electrical grid, particularly in large machines.\n\nIn a conventional direct-current motor or direct-current generator with a commutator, the stator usually supplies the main field through wound poles or permanent magnets, while the armature rotates. By contrast, a brushless DC motor normally has stationary armature windings energized in sequence by electronic switching.\n\nThe terms stator and armature are therefore not interchangeable: the former identifies mechanical motion, while the latter identifies an electromagnetic function."
    },
    {
      "heading": "Construction and materials",
      "text": "A common stator core is assembled from thin, electrically insulated sheets of electrical steel. Laminating the core limits circulating eddy currents caused by changing magnetic flux and reduces the associated heating. The steel’s magnetic properties also help reduce hysteresis losses.\n\nSlots in the core accommodate insulated copper or, in some designs, aluminum conductors. Common winding arrangements include:\n\n- Distributed windings, in which coils belonging to a phase occupy multiple slots around the stator.\n- Concentrated windings, in which coils are grouped around individual teeth or a small number of slots.\n- Formed rectangular-conductor windings, including hairpin constructions used in some traction motors.\n\nThese categories are not all mutually exclusive: conductor construction and spatial winding arrangement describe different aspects of a winding.\n\nSlot insulation, conductor insulation, wedges, bindings, and impregnating resins provide electrical separation and mechanical support. End windings—the portions extending beyond the active core—require particular attention because they occupy space, generate heat, and experience electromagnetic forces without contributing directly to torque production along the active core length.\n\nNot every stator uses a conventional slotted laminated core. Slotless, coreless, and soft-magnetic-composite designs serve applications with different requirements for weight, geometry, losses, and torque smoothness."
    },
    {
      "heading": "Cooling, losses, and reliability",
      "text": "Electrical stators generate heat through winding resistance and magnetic losses. Winding resistance loss is commonly expressed as\n\n\\[P_{\\mathrm{Cu}}=\\sum_k I_{k,\\mathrm{rms}}^2R_k,\\]\n\nwhere the sum covers the relevant winding circuits. Additional losses can arise from leakage fields, harmonics, and eddy currents within the conductors.\n\nCooling methods include natural or forced airflow, liquid-cooled housings, direct oil cooling, and internal cooling passages. Some large generators use hydrogen cooling or water flowing through hollow stator conductors. The appropriate arrangement depends on power rating, duty, allowable temperature, and construction.\n\nImportant failure mechanisms include insulation aging, turn-to-turn short circuits, ground faults, loose windings, cooling-system problems, and damage to interlaminar insulation. In high-voltage machines, partial discharge can contribute to insulation deterioration. Temperature, vibration, and electrical measurements provide information about operating condition.\n\nDesign involves trade-offs. A smaller air gap can improve magnetic coupling but demands tighter manufacturing tolerances. Greater electrical loading can increase torque density but raises cooling requirements. Switching from a power inverter can introduce additional losses and electrical stress that are not fully represented by operation on a sinusoidal supply."
    },
    {
      "heading": "Stators in turbomachinery",
      "text": "In a steam turbine or gas turbine, stationary nozzle rows or guide vanes direct and often accelerate the working fluid before it enters a rotor row. Their geometry establishes the flow angle and velocity needed for the rotor to extract energy efficiently.\n\nIn an axial compressor, a rotor adds energy to the fluid, while a following stator commonly reduces swirl and diffuses the flow, converting part of its kinetic energy into static pressure. The detailed division of pressure change between rotor and stator depends on the stage design. Some compressors use adjustable stator vanes to maintain suitable flow conditions over a range of operating speeds and loads.\n\nBecause a stationary vane row performs no shaft work, its function differs fundamentally from that of a rotor. Under an ideal adiabatic approximation, stagnation enthalpy remains constant through the stator even though velocity and static pressure may change. Real stators introduce aerodynamic losses through friction, separation, leakage, and mixing.\n\nUnlike an electrical-machine stator, a turbomachinery stator is designed primarily around fluid flow, structural loading, erosion resistance, and temperature capability. The shared term identifies the stationary role, not a common energy-conversion mechanism."
    }
  ],
  "links": [
    "rotor",
    "electric-motor",
    "electric-generator",
    "magnetic-field",
    "three-phase-electric-power",
    "induction-motor",
    "synchronous-motor",
    "variable-frequency-drive",
    "electrical-grid",
    "dc-motor",
    "commutator",
    "brushless-dc-motor",
    "power-inverter",
    "steam-turbine",
    "gas-turbine"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}