  "id": "relative-humidity",
  "title": "Relative Humidity",
  "lang": "en",
  "source_lang": "en",
  "summary": "Relative humidity measures water-vapor pressure relative to saturation at the same temperature, linking atmospheric moisture to weather, living organisms, and materials.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "RH",
    "percent relative humidity"
  ],
  "generated_at": "2026-11-03",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/relative-humidity/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/relative-humidity/",
      "json": "https://aiwiki.page/zh/relative-humidity.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "Relative humidity is the ratio of the actual water-vapor pressure in a gas to the saturation vapor pressure at the same temperature, usually expressed as a percentage. In ordinary atmospheric applications, the gas is air and the reference surface is liquid water. A relative humidity of 50% means that the vapor pressure is half the value associated with equilibrium over a flat surface of liquid water at that temperature. It does not mean that half the air consists of water, nor that the air contains half of a fixed maximum amount of moisture.\n\nRelative humidity connects the moisture content of the atmosphere with evaporation, condensation, and the exchange of water between air and materials. It helps describe the formation of clouds and fog, the drying of soils and products, the water balance of organisms, and moisture conditions inside buildings. Because saturation vapor pressure depends strongly on temperature, relative humidity can change substantially even when no water vapor is added or removed.\n\nIts interpretation therefore requires attention to temperature, the reference phase of water, and the measurement method. The same numerical relative humidity can correspond to very different quantities of atmospheric water vapor, while a single air mass can produce different relative humidities at warm and cold surfaces."
    },
    {
      "heading": "Definition, reference conditions, and physical meaning",
      "text": "For most meteorological and engineering calculations, relative humidity is written as\n\n\\[\\mathrm{RH}=100\\frac{e}{e_s(T)},\\]\n\nwhere \\(e\\) is the partial pressure of water vapor and \\(e_s(T)\\) is the saturation vapor pressure at temperature \\(T\\). Both pressures must be expressed in the same units. The ratio itself is dimensionless; multiplication by 100 expresses it as a percentage. Reports commonly use the notation “50% RH” to distinguish the measured quantity from other percentages.\n\nSaturation is a condition of dynamic thermodynamic equilibrium. At a flat water surface in equilibrium with its vapor, water molecules leave and return to the liquid at equal average rates. The equilibrium vapor pressure depends primarily on temperature because temperature changes the molecular energy distribution and the difference in chemical potential between the liquid and vapor phases. The familiar statement that warm air “holds more water” is a convenient shorthand, but it can obscure the mechanism: saturation vapor pressure is a property of phase equilibrium, not a storage capacity provided by nitrogen and oxygen.\n\nThe reference phase matters below freezing. Saturation vapor pressure over ice is lower than saturation vapor pressure over supercooled liquid water at the same temperature. An air sample can consequently be unsaturated relative to liquid water but supersaturated relative to ice. Meteorological reports generally express surface relative humidity with respect to liquid water, including at many subfreezing temperatures, whereas upper-atmosphere and cloud studies may explicitly report humidity relative to ice. At about \\(-10\\,^\\circ\\mathrm{C}\\), saturation vapor pressures are approximately 2.86 hPa over liquid water and 2.60 hPa over ice. An actual vapor pressure of 2.70 hPa therefore corresponds to roughly 94% relative humidity with respect to water but 104% with respect to ice.\n\nThe simple pressure ratio is highly useful, but precision metrology also accounts for the behavior of moist air as a real gas. Interactions between water vapor and the other gases slightly modify the equilibrium vapor pressure compared with that above pure water in the absence of air. An enhancement factor can represent this correction; its magnitude depends on temperature and total pressure. It is small under ordinary near-surface conditions but becomes important in high-accuracy calibration and at elevated pressures.\n\nA value of 100% RH describes saturation under the stated reference conditions, not necessarily visible mist or liquid droplets. Conversely, relative humidity greater than 100% is physically possible. Such supersaturation can persist when the formation of a new condensed phase is inhibited or when cooling produces vapor excess faster than condensation removes it. Whether condensation occurs depends on surfaces, particles, curvature, and the rates of heat and mass transfer."
    },
    {
      "heading": "Temperature dependence and changes of state",
      "text": "The strong temperature dependence of relative humidity follows from the thermodynamics of vaporization. An approximate form of the Clausius–Clapeyron equation is\n\n\\[\\frac{d\\ln e_s}{dT}=\\frac{L_v}{R_vT^2},\\]\n\nwhere \\(T\\) is absolute temperature, \\(L_v\\) is the specific latent heat of vaporization, and \\(R_v\\) is the specific gas constant for water vapor. The expression assumes approximately ideal behavior of the vapor and neglects the liquid’s specific volume relative to that of the vapor. Because \\(L_v\\) varies with temperature, accurate saturation calculations use more detailed expressions. Near typical surface temperatures, saturation vapor pressure increases by roughly 6–7% per degree Celsius.\n\nThis dependence explains why heating air often reduces its relative humidity. If an air sample is warmed at approximately constant total pressure without adding or removing water, its water-vapor mixing ratio and vapor pressure remain approximately constant, while \\(e_s\\) increases. Saturation vapor pressure is about 12.28 hPa at \\(10\\,^\\circ\\mathrm{C}\\), 23.39 hPa at \\(20\\,^\\circ\\mathrm{C}\\), and 42.46 hPa at \\(30\\,^\\circ\\mathrm{C}\\). Air saturated at \\(10\\,^\\circ\\mathrm{C}\\), when warmed to \\(20\\,^\\circ\\mathrm{C}\\) under these conditions, has a relative humidity of about 52.5%. Warming has not removed its vapor; it has changed the reference against which that vapor is measured.\n\nCooling produces the reverse effect until saturation is reached. The dew point is the temperature at which the existing vapor pressure equals saturation vapor pressure over liquid water. Air at \\(20\\,^\\circ\\mathrm{C}\\) and 50% RH has a vapor pressure of approximately 11.7 hPa and a dew point near \\(9.3\\,^\\circ\\mathrm{C}\\). A surface colder than that dew point can collect condensation even though the surrounding room is far below 100% RH. The corresponding saturation temperature over ice is termed the frost point; it differs from the liquid-water dew point below freezing.\n\nThe physical constraints on a temperature change must be specified. In a sealed rigid vessel, warming a fixed amount of water vapor raises its partial pressure approximately in proportion to absolute temperature, in accordance with the ideal-gas relationship. Relative humidity nevertheless usually falls because saturation vapor pressure rises much faster. During atmospheric ascent, both temperature and pressure decrease. Before condensation begins, the vapor mixing ratio can remain nearly constant even though vapor pressure decreases; the stronger decline in saturation vapor pressure causes relative humidity to rise.\n\nCondensation and evaporation also feed back on temperature. Condensation releases latent heat, reducing the rate at which rising saturated air cools. Evaporation absorbs heat and can cool air or a wetted surface. Thus relative humidity is not merely a passive indicator: the phase changes associated with it alter the thermal conditions that determine subsequent saturation."
    },
    {
      "heading": "Relationship to other measures of atmospheric moisture",
      "text": "Relative humidity is one of several moisture variables, each suited to different questions. Absolute humidity is the mass of water vapor per unit volume, often expressed in grams per cubic metre. Specific humidity is the mass of water vapor divided by the total mass of moist air. The water-vapor mixing ratio is the mass of vapor divided by the mass of dry air. Dew point expresses moisture through a saturation temperature, whereas relative humidity describes proximity to saturation at the current temperature. These quantities are related, but they are not interchangeable.\n\nFor moist air approximated as a mixture of ideal gases, the mixing ratio \\(r\\) and specific humidity \\(q\\) can be obtained from vapor pressure and total pressure:\n\n\\[r=\\frac{\\epsilon e}{p-e}, \\qquad q=\\frac{\\epsilon e}{p-(1-\\epsilon)e},\\]\n\nwhere \\(p\\) is total pressure and \\(\\epsilon\\approx0.622\\) is the ratio of the molar mass of water to that of dry air. Vapor density follows approximately from\n\n\\[\\rho_v=\\frac{e}{R_vT}.\\]\n\nThese equations explain why a relative-humidity measurement alone does not uniquely specify the mass of water in an air sample. Temperature is needed to obtain vapor pressure, and pressure is additionally needed to convert that pressure into a mixing ratio or specific humidity.\n\nFor example, at \\(20\\,^\\circ\\mathrm{C}\\) and 50% RH, vapor pressure is approximately 1.17 kPa and vapor density is about 8.6 grams per cubic metre. At \\(30\\,^\\circ\\mathrm{C}\\) and the same relative humidity, vapor pressure is approximately 2.12 kPa and vapor density is about 15.2 grams per cubic metre. The warmer sample contains substantially more vapor per unit volume despite having the same stated percentage. Similarly, cold outdoor air can have high relative humidity but a low dew point; when brought indoors and heated without humidification, it can produce low indoor relative humidity.\n\nThe vapor-pressure deficit is another important quantity:\n\n\\[D=e_s(T)-e.\\]\n\nUnlike relative humidity, it expresses an absolute pressure difference. Air at \\(20\\,^\\circ\\mathrm{C}\\) and 50% RH has a deficit of about 1.17 kPa; at \\(30\\,^\\circ\\mathrm{C}\\) and 50% RH, the deficit is about 2.12 kPa. This difference is important in plant-water relations and drying processes. For transfer from a leaf or other wet surface, however, the relevant vapor-pressure difference uses saturation pressure at the surface temperature, which may differ from air temperature.\n\nWet-bulb temperature supplies still another perspective. It is the temperature approached by a wetted sensor exposed to adequate airflow under specified conditions. Evaporative cooling makes it lower than the ordinary dry-bulb temperature when the air is unsaturated. Psychrometrics combines these quantities with moist-air enthalpy and specific volume to analyze heating, cooling, mixing, and moisture removal. Its charts display why processes that appear similar in relative-humidity terms may involve quite different water and energy balances."
    },
    {
      "heading": "Clouds, fog, and atmospheric variability",
      "text": "Relative humidity varies through the day, with altitude, and among air masses. Near the ground, a common fair-weather pattern is high relative humidity near sunrise and lower relative humidity in the afternoon. Overnight cooling reduces saturation vapor pressure, while daytime heating increases it. This cycle can occur with relatively little change in actual vapor content. Evaporation, plant transpiration, turbulent mixing, and the arrival of different air masses can strengthen, weaken, or reverse the pattern.\n\nCloud formation commonly begins when air cools during ascent. In an unsaturated adiabatic process, a rising parcel cools at approximately \\(9.8\\,^\\circ\\mathrm{C}\\) per kilometre under typical lower-atmosphere conditions. Its dew point usually decreases more slowly. When temperature and dew point converge, the parcel approaches saturation. The lifting condensation level provides an approximate cloud-base height for air lifted from a known starting state. Above that level, condensation releases latent heat, and the parcel’s cooling rate becomes smaller and depends on temperature and moisture content.\n\nAtmospheric condensation usually occurs on aerosol particles rather than by spontaneous formation of pure droplets. Soluble substances reduce the equilibrium vapor pressure over a droplet, while the curvature of a very small droplet increases it. Köhler theory describes the competition between these effects and the supersaturation required to activate a particle into a cloud droplet. Consequently, cloud formation depends on particle size and composition as well as relative humidity. Supersaturations in many liquid-water clouds are small, commonly fractions of one percent, but they are sufficient to activate suitable particles.\n\nIce clouds introduce additional complexity. At subfreezing temperatures, an atmosphere saturated with respect to supercooled droplets is already supersaturated with respect to ice. Where ice crystals and liquid droplets coexist, this difference can favor vapor transfer from liquid water to ice, contributing to precipitation development. In the cold upper troposphere, layers supersaturated with respect to ice can exist without widespread visible cloud. Such conditions are important for the persistence of aircraft contrails, whose ice crystals can continue growing when the surrounding air supplies sufficient vapor.\n\nFog involves suspended droplets near the ground, whereas dew forms directly on a surface. Radiation fog often develops when nocturnal heat loss cools near-surface air toward saturation; advection fog can form when moist air moves over a colder surface. Neither process can be inferred from a regional humidity percentage alone, because local temperature, wind, surface conditions, and mixing matter. Relative humidity also affects visibility below saturation: hygroscopic particles take up water, grow, and scatter more light. This can intensify haze without producing a conventional cloud or fog layer."
    },
    {
      "heading": "Instruments, calibration, and observational uncertainty",
      "text": "Instruments for humidity measurement are called hygrometers. Their history reflects several different physical approaches. Horace-Bénédict de Saussure developed a hair hygrometer in the eighteenth century, exploiting changes in the length of prepared hair as it exchanges moisture with the air. Such mechanical instruments made continuous recording possible but were affected by temperature, contamination, friction, and aging. Psychrometers instead infer humidity from evaporative cooling, while modern electronic sensors commonly detect moisture-dependent changes in an electrical property.\n\nA psychrometer uses a dry-bulb thermometer and a second thermometer covered by a wetted wick. When evaporation occurs, the wet bulb cools below the dry bulb. A simplified psychrometric equation is\n\n\\[e=e_s(T_w)-A p(T_d-T_w),\\]\n\nwhere \\(T_w\\) and \\(T_d\\) are wet- and dry-bulb temperatures, \\(p\\) is atmospheric pressure, and \\(A\\) is a coefficient appropriate to the instrument and ventilation conditions. Reliable measurements require adequate airflow, clean water and wick material, and protection from radiation. Ice on the wick requires different treatment from liquid water. The aspirated psychrometer associated with Richard Assmann’s late-nineteenth-century work improved control of ventilation and radiation exposure.\n\nMany compact electronic instruments use a moisture-sensitive polymer whose capacitance changes as water is absorbed. Others measure electrical resistance or impedance. Their advantages include small size, low power consumption, and easy integration with data loggers. Limitations include response lag, hysteresis between humidification and drying, drift, and sensitivity to contaminants. A sensor that has been wetted by condensation may require time to recover. Its quoted accuracy normally applies only within specified temperature and humidity ranges and does not automatically describe performance after prolonged exposure to harsh conditions.\n\nA chilled-mirror hygrometer measures dew point by cooling a reflective surface and detecting the onset of condensation optically. With careful temperature measurement and surface control, it can serve as a high-quality reference instrument. At subfreezing temperatures, identifying whether the deposit is liquid water, ice, or a changing mixture is important. Humidity generators and saturated salt solutions provide controlled calibration environments. For example, a saturated sodium chloride solution establishes an equilibrium relative humidity of approximately 75% near room temperature, with the exact value depending on temperature and solution conditions.\n\nTemperature errors are often central to measurement uncertainty. Near \\(20\\,^\\circ\\mathrm{C}\\), saturation vapor pressure changes by about 6% per kelvin. A humidity sensor just 1 K warmer than the sampled air can therefore indicate several percentage points less RH than the true ambient value. Solar heating, nearby electronics, and poor ventilation can create such offsets. Calibration establishes an instrument’s response under controlled conditions, but good field measurements also require representative exposure, synchronized temperature measurements, and documentation of sensor replacements, processing algorithms, and maintenance."
    },
    {
      "heading": "Organisms, evaporation, and moisture exchange",
      "text": "Relative humidity influences living organisms primarily through water exchange rather than through the percentage value itself. Evaporation from a moist biological surface depends on the difference between vapor pressure at that surface and in the surrounding air, together with resistance to transport. Surface temperature, air movement, and the thickness of the adjacent boundary layer all matter. Two environments with the same relative humidity can therefore impose different evaporative demands, and two organisms in the same air can experience different water-loss rates.\n\nIn plants, the internal leaf air spaces are often close to saturation at leaf temperature. Water vapor moves outward through stomata and across the external boundary layer. The resulting transpiration contributes to the movement of water from soil through roots and stems to leaves. As atmospheric vapor-pressure deficit increases, stomata in many species partially close, limiting water loss but also restricting the entry of carbon dioxide for photosynthesis. Responses differ among species, developmental stages, and water-supply conditions. This is one reason agricultural studies commonly analyze vapor-pressure deficit alongside relative humidity rather than treating RH as a complete measure of atmospheric dryness.\n\nHumidity also enters estimates of evapotranspiration, the combined water loss from vegetation and other surfaces. In the Penman–Monteith framework, vapor-pressure deficit contributes to the aerodynamic component of the calculation, while available energy, wind, and surface and aerodynamic resistances also influence the result. High relative humidity generally reduces evaporative demand when other conditions are unchanged, but it does not by itself determine water use. A sunny, windy environment can sustain substantial evaporation even at moderately high RH, whereas low radiation can constrain evaporation in comparatively dry air.\n\nFor humans and other animals that use evaporative cooling, ambient vapor pressure affects the ability to dissipate metabolic heat. Sweat cools skin when it evaporates; sweat that drips away provides much less evaporative cooling. Thermoregulatory conditions therefore depend on air and skin temperatures, humidity, airflow, radiation, clothing, and metabolic activity. Measures such as heat index and wet-bulb temperature combine some of these variables in different ways. Relative humidity alone is not a direct measure of heat stress: a high percentage on a cold day has a different physiological meaning from the same percentage in hot conditions.\n\nMicroorganisms and stored biological materials respond strongly to water availability at their immediate surfaces. Water activity, rather than bulk water content alone, describes how available water is for chemical and biological processes. When a material and the surrounding vapor reach equilibrium at the same temperature, equilibrium RH is approximately 100 times the material’s water activity. Growth limits differ among bacteria, yeasts, and molds, and temperature and substrate composition also matter. A room-average RH value may therefore fail to represent the microenvironment within a damp food, porous wall, leaf surface, or packaging system."
    },
    {
      "heading": "Buildings, materials, and industrial processes",
      "text": "Indoor relative humidity results from the interaction of moisture sources, ventilation, air leakage, temperature control, and exchanges with building materials. Cooking, bathing, occupants, plants, and wet construction materials can introduce vapor. Outdoor air may add or remove moisture depending on its vapor content, not simply on whether its relative humidity is higher or lower than the indoor value. Heating generally lowers RH without removing water; cooling raises RH until condensation begins. Air-conditioning equipment removes water when air contacts a coil below its dew point and the condensate drains away.\n\nLocal surface temperature is often more informative than room-average RH for understanding condensation. Consider indoor air at \\(20\\,^\\circ\\mathrm{C}\\) and 60% RH: its dew point is about \\(12\\,^\\circ\\mathrm{C}\\). A window or thermal bridge below that temperature can become wet. Even above the dew point, the local relative humidity next to a cold surface can be much higher than in the room because saturation vapor pressure is lower there. Moisture can also move into building assemblies through air leakage, vapor diffusion, and liquid transport. These mechanisms operate on different scales and cannot all be assessed from a single indoor humidity reading.\n\nPorous and hygroscopic materials exchange water with air until approaching an equilibrium moisture content. Wood, paper, textiles, and many polymers consequently change dimensions or mechanical properties as RH changes. Their moisture content is described by sorption isotherms, which depend on temperature and often show hysteresis: the equilibrium state reached during drying differs from that reached during wetting. Adsorption onto internal surfaces and capillary condensation in small pores help explain why materials can retain substantial moisture without visible liquid water on their exterior.\n\nThese processes are important in museums, archives, and manufacturing. Repeated dimensional changes can stress composite objects in which wood, paint, adhesives, and other components respond differently. Conservation practice therefore considers the material, its previous environment, and the rate and amplitude of humidity changes rather than assuming that a single percentage is universally appropriate. Moisture also affects the corrosion of metals, especially where deposited salts form conductive surface films. Certain salts undergo deliquescence, absorbing vapor until they form a solution above a characteristic humidity; drying may reverse the process at a different threshold.\n\nIndustrial humidity control uses humidifiers, refrigeration-based dehumidification, desiccants, and controlled ventilation. In drying operations, removing moist boundary-layer air can be as important as lowering the incoming RH. In compressed-air systems, cooling after compression can cause condensation, and pressure dew point is specified at the operating pressure. Semiconductor production, pharmaceutical manufacture, food processing, and textile production each impose different moisture requirements. Very dry conditions can increase electrostatic charging, while excessive moisture can alter product dimensions, promote unwanted reactions, or cause condensation. Process specifications consequently identify temperature, measurement location, tolerances, and sometimes dew point or water content in addition to RH."
    },
    {
      "heading": "Climate interpretation and long-term records",
      "text": "Relative humidity is an important climate variable, but it must be distinguished from the total amount of atmospheric water vapor. Because saturation vapor pressure rises rapidly with temperature, warmer air can contain more vapor at unchanged relative humidity. A nearly constant global or regional RH therefore does not imply an unchanged atmospheric moisture burden. Conversely, decreasing relative humidity does not necessarily mean that specific humidity has decreased: actual vapor content may have risen, but by less than the increase in saturation vapor pressure.\n\nThis distinction is central to water-vapor feedback in climate change. Water vapor is a greenhouse gas, and atmospheric warming generally increases the amount of vapor present. The additional vapor strengthens infrared absorption and amplifies the initial warming. The response is often described using approximately conserved relative humidity as a useful large-scale approximation, rather than as an exact physical constraint. Relative humidity can vary with circulation, altitude, season, land-surface conditions, and the balance between moisture supply and warming.\n\nLand and ocean need not respond identically. Over an ocean, an extensive water source supports evaporation, although actual fluxes also depend on wind, stability, and the air–sea humidity difference. Over land, soil moisture, vegetation, and transport from other regions constrain the supply. Land can warm more rapidly than the ocean, allowing saturation vapor pressure to increase faster than atmospheric vapor pressure and thereby lowering land relative humidity. Such changes can increase vapor-pressure deficit and affect vegetation and drying, but the response is spatially variable and interacts with precipitation and circulation changes.\n\nLong-term humidity records combine surface instruments, balloon-borne radiosondes, satellite observations, and atmospheric reanalyses. Each has distinct limitations. Radiosonde humidity sensors can exhibit slow response and radiation-related biases, particularly in cold, dry upper-air conditions. Satellites usually retrieve moisture over atmospheric layers rather than measure a sharply defined local RH directly. Reanalyses combine observations with numerical models and are affected by changes in the observing system. Establishing trends requires attention to station relocations, sensor changes, calibration histories, and the consistency of temperature and vapor measurements.\n\nAveraging also changes interpretation because relative humidity is a nonlinear function of temperature. The mean of hourly RH values is generally not equal to the RH calculated from mean temperature and mean vapor pressure. Daily minimum RH, nighttime maximum RH, seasonal mean RH, and the frequency of near-saturation conditions describe different aspects of an environment. Comparisons between places or periods are therefore most informative when the sampling times, reference phase, measurement height, and averaging method are specified, with temperature and a vapor-content variable reported alongside relative humidity."
    }
  ],
  "links": [
    "temperature",
    "water",
    "atmosphere-of-earth",
    "evaporation",
    "condensation",
    "partial-pressure",
    "thermodynamic-equilibrium",
    "chemical-potential",
    "metrology",
    "pressure",
    "latent-heat",
    "dew-point",
    "ideal-gas",
    "density",
    "vapor-pressure-deficit",
    "enthalpy",
    "adiabatic-process",
    "light",
    "capacitance",
    "electrical-resistance",
    "measurement-uncertainty",
    "calibration",
    "carbon-dioxide",
    "photosynthesis",
    "species",
    "evapotranspiration",
    "heat",
    "thermoregulation",
    "bacteria",
    "diffusion",
    "adsorption",
    "museum",
    "climate",
    "feedback",
    "climate-change",
    "greenhouse-gas",
    "ocean"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}