  "id": "power-physics",
  "title": "Power (Physics)",
  "lang": "en",
  "source_lang": "en",
  "summary": "Power is the rate at which energy is transferred or transformed, or work is performed, measured in watts.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Physical power",
    "Rate of energy transfer",
    "Rate of doing work"
  ],
  "generated_at": "2026-11-03",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/power-physics/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/power-physics/",
      "json": "https://aiwiki.page/zh/power-physics.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "Power is the rate at which energy is transferred between systems or converted from one form into another. When energy transfer occurs through work, power is the rate of doing work. It describes how quickly a process takes place energetically, rather than the total energy involved: two motors may lift the same load through the same height, but the motor that completes the task in less time delivers greater average power. The SI unit is the watt, equal to one joule per second.\n\nPower provides a common language for processes that otherwise appear very different, including moving machinery, electric circuits, heat engines, sound waves, and stellar radiation. Its calculation depends on the mechanism of energy transfer: mechanical power involves force and velocity, electrical power involves voltage and current, and heat-transfer power depends on thermal transport. Distinguishing instantaneous from average power, useful output from input, and actual transfer from a device’s rated capacity is essential to interpreting physical measurements and engineering specifications."
    },
    {
      "heading": "Definition, time dependence, and energy accounting",
      "text": "For an amount of energy \\(\\Delta E\\) transferred during a time interval \\(\\Delta t\\), average power is\n\n\\[P_{\\mathrm{avg}}=\\frac{\\Delta E}{\\Delta t}.\\]\n\nInstantaneous power is the limiting rate,\n\n\\[P(t)=\\frac{dE_{\\mathrm{transferred}}}{dt}.\\]\n\nHere, \\(E_{\\mathrm{transferred}}\\) denotes accumulated energy crossing a boundary or passing through a specified conversion process. It need not equal the energy stored inside the system. A motor operating steadily can receive electrical energy and deliver mechanical energy continuously while its own stored energy remains nearly constant. Thus, the derivative of a system’s stored energy and the power passing through it are generally different quantities.\n\nThe distinction follows directly from energy accounting. For a system with identifiable incoming and outgoing energy transfers,\n\n\\[\\frac{dE_{\\mathrm{system}}}{dt} = \\sum P_{\\mathrm{in}}-\\sum P_{\\mathrm{out}}.\\]\n\nThis is a rate form of the first law of thermodynamics. At steady state, the left-hand side vanishes, although individual incoming and outgoing powers may be large. During charging, a battery stores part of its incoming power as chemical energy; during discharge, its stored energy decreases while it supplies electrical power and releases heat. The system boundary determines which transfers appear explicitly in the equation.\n\nPower can vary rapidly even when its average is steady. If \\(P(t)\\) is known, the transferred energy is obtained by integration:\n\n\\[\\Delta E=\\int_{t_1}^{t_2}P(t)\\,dt.\\]\n\nA device drawing \\(2\\,\\mathrm{kW}\\) for three hours receives \\(6\\,\\mathrm{kWh}\\), or \\(21.6\\,\\mathrm{MJ}\\). A kilowatt-hour is therefore a unit of energy, not power. Conversely, stating that a machine uses a certain number of joules does not specify its power unless the transfer time is also given. For repeated cycles, the averaging interval must be stated or understood: averaging over a single electrical cycle, an hour, and a year can answer very different questions.\n\nSigned power indicates the direction of energy transfer under a chosen convention. A force can supply positive mechanical power to an object or absorb mechanical power from it. An electrical machine can consume power as a motor and return power as a generator. Such signs do not represent positive or negative amounts of stored energy; they identify a direction relative to the defined boundary or variables. For isolated systems, internal transfers cancel in the total energy balance, although substantial power may circulate among their parts."
    },
    {
      "heading": "Units, dimensional structure, and historical development",
      "text": "In the International System of Units (SI), power has the coherent derived unit watt, symbol \\(\\mathrm{W}\\):\n\n\\[1\\,\\mathrm{W} = 1\\,\\mathrm{J\\,s^{-1}} = 1\\,\\mathrm{kg\\,m^2\\,s^{-3}}.\\]\n\nThe joule measures energy, while the second supplies the time scale. Power consequently has dimensions \\(ML^2T^{-3}\\). Common multiples include the kilowatt, megawatt, gigawatt, and terawatt, respectively \\(10^3\\), \\(10^6\\), \\(10^9\\), and \\(10^{12}\\) watts. Milliwatts and microwatts are widely used for electronic components, optical signals, and small heat flows. Unit symbols are case-sensitive: \\(\\mathrm{mW}\\) and \\(\\mathrm{MW}\\) differ by a factor of one billion.\n\nThe watt is named after James Watt, whose improvements to the steam engine helped make mechanical output a major commercial measurement in the late eighteenth century. The name “watt” was proposed as a power unit by C. William Siemens in 1882 and adopted internationally for electrical use in 1889. It became part of the SI when that system was established in 1960. Modern SI power measurements ultimately depend on definitions involving fixed fundamental constants and on practical realizations of the relevant electrical, mechanical, and time units.\n\nBefore the watt became standard, engine performance was commonly expressed in horsepower. Watt promoted horsepower as a way to compare steam engines with working horses. The widely used mechanical horsepower is defined as \\(550\\) foot-pounds-force per second, approximately \\(745.7\\,\\mathrm{W}\\). Metric horsepower is \\(75\\) kilogram-force metres per second, approximately \\(735.5\\,\\mathrm{W}\\). These are different units despite their similar names. Boiler horsepower is different again: it describes a standardized thermal evaporation rate and is about \\(9.81\\,\\mathrm{kW}\\), not the shaft output of an engine.\n\nThe development of power measurement accompanied the separation of force, work, and energy as physical concepts. A large force does not necessarily imply a large power, and the ability to do a large total amount of work does not specify how rapidly it can be done. During the nineteenth century, studies of engines, electricity, and heat established that these processes could be compared through a common energy balance. Experiments associated with James Prescott Joule helped establish the quantitative equivalence of mechanical work and heat.\n\nSeveral units and expressions can obscure these distinctions. A watt per second measures the rate at which power changes, not energy consumption. A watt-hour measures energy. A watt per square metre measures power per area, as in irradiance or heat flux. A watt per kilogram measures specific power, an important measure for motors and batteries, but it is not interchangeable with energy per kilogram. Logarithmic quantities such as decibels express ratios; dBW and dBm specify power relative to \\(1\\,\\mathrm{W}\\) and \\(1\\,\\mathrm{mW}\\), respectively."
    },
    {
      "heading": "Mechanical power in translation, rotation, and fluid flow",
      "text": "For a particle acted on by a force \\(\\mathbf F\\), the incremental work is \\(dW=\\mathbf F\\cdot d\\mathbf r\\). Dividing by time gives\n\n\\[P=\\mathbf F\\cdot\\mathbf v,\\]\n\nwhere \\(\\mathbf v\\) is the velocity of the point of application. The dot product is essential: only the component of force along the motion contributes to power. A force perpendicular to velocity does no instantaneous work. In uniform circular motion, for example, the net centripetal force changes the direction of momentum without changing speed or supplying net power to the particle.\n\nThe work–energy theorem relates the sum of the powers of forces on a particle to the rate of change of its kinetic energy. For a body moving at constant speed, the net power can be zero while a motor supplies positive power and resistive forces absorb an equal amount. An idealized lift raising a \\(1{,}000\\,\\mathrm{kg}\\) mass vertically at \\(1\\,\\mathrm{m\\,s^{-1}}\\) requires approximately \\(9.81\\,\\mathrm{kW}\\) of mechanical output near Earth’s surface, excluding losses and acceleration. Holding the mass stationary requires no mechanical power delivered to the mass, even if the supporting equipment consumes electrical energy internally.\n\nFor rotation about a fixed axis, the corresponding expression is\n\n\\[P=\\tau\\omega,\\]\n\nwhere \\(\\tau\\) is the component of torque about the axis and \\(\\omega\\) is angular speed. A shaft transmitting \\(100\\,\\mathrm{N\\,m}\\) at \\(3{,}000\\) revolutions per minute carries about \\(31.4\\,\\mathrm{kW}\\). Torque and power are therefore not competing measures of the same property: torque describes rotational loading, while power also includes rotational speed. An ideal gearbox can increase output torque by reducing speed, but cannot increase power. Real gears deliver less output power because of friction and other losses.\n\nMechanical power is frame-dependent. Under a change between inertial reference frames moving at a constant relative velocity \\(\\mathbf U\\), Newtonian mechanics gives \\(\\mathbf v'=\\mathbf v-\\mathbf U\\), and therefore \\(P'=P-\\mathbf F\\cdot\\mathbf U\\). The kinetic energy and its rate of change also change between frames. This is consistent with energy conservation because the whole calculation, including the work performed by other bodies, must use the same frame. For extended objects, deformation and the motion of individual contact points can also matter.\n\nIn fluid machinery, an important approximation is\n\n\\[P_{\\mathrm{hydraulic}}=\\Delta p\\,Q,\\]\n\nwhere \\(\\Delta p\\) is the pressure increase and \\(Q\\) is volume flow rate. Pumping \\(0.01\\,\\mathrm{m^3\\,s^{-1}}\\) against \\(200\\,\\mathrm{kPa}\\) requires \\(2\\,\\mathrm{kW}\\) of hydraulic power, with greater shaft input needed because of losses. For water falling through a height \\(h\\), the available gravitational power is approximately \\(\\rho gQh\\). These formulas assume conditions under which changes in kinetic energy, compressibility, and other contributions can be neglected or treated separately. Wind turbines instead intercept a kinetic-energy flux proportional to \\(\\tfrac12\\rho Av^3\\); not all of that flux can be extracted."
    },
    {
      "heading": "Electrical power in direct-current and alternating-current systems",
      "text": "At an electrical port, instantaneous power is\n\n\\[p(t)=v(t)i(t),\\]\n\nwhere \\(v\\) is the voltage across the port and \\(i\\) is the current through it. Under the passive sign convention, current entering the terminal labeled positive gives positive absorbed power. Negative power then indicates delivery to the external circuit. This convention applies to both consumers and sources: a rechargeable battery absorbs electrical power while charging and delivers it while discharging. Voltage represents energy transferred per unit charge, so multiplying by charge flow per unit time gives energy transfer per unit time.\n\nFor steady direct current, \\(P=VI\\). In a resistor obeying Ohm’s law, this becomes\n\n\\[P=I^2R=\\frac{V^2}{R}.\\]\n\nThe absorbed electrical energy is converted chiefly into internal energy through Joule heating. These expressions require the appropriate resistance at the operating conditions; resistance may change strongly with temperature. A \\(12\\,\\mathrm{V}\\) load drawing \\(2\\,\\mathrm{A}\\) absorbs \\(24\\,\\mathrm{W}\\), but that number alone does not say how much becomes light, motion, sound, or heat. Those proportions depend on the device’s conversion processes.\n\nFor sinusoidal alternating current, voltage and current may differ in phase. If their root-mean-square values are \\(V_{\\mathrm{rms}}\\) and \\(I_{\\mathrm{rms}}\\), and their phase difference is \\(\\phi\\), the average active power is\n\n\\[P=V_{\\mathrm{rms}}I_{\\mathrm{rms}}\\cos\\phi.\\]\n\nThe apparent power is \\(S=V_{\\mathrm{rms}}I_{\\mathrm{rms}}\\), conventionally expressed in volt-amperes. Reactive power is \\(Q=V_{\\mathrm{rms}}I_{\\mathrm{rms}}\\sin\\phi\\), expressed in vars. For sinusoidal steady-state conditions, \\(S^2=P^2+Q^2\\). Reactive power describes alternating energy exchange with electric and magnetic storage elements rather than net energy consumption over a full cycle.\n\nThe power factor is the ratio \\(P/S\\). For sinusoidal voltage and current it equals \\(\\cos\\phi\\), but nonlinear loads can draw distorted currents, making waveform distortion important as well. A load absorbing \\(1\\,\\mathrm{kW}\\) at power factor \\(0.5\\) requires \\(2\\,\\mathrm{kVA}\\) of apparent power. At the same voltage, it draws more current than a unity-power-factor load with the same active power. The increased current raises conductor losses and uses more of the current-carrying capacity of cables, transformers, and generators.\n\nIn balanced three-phase systems, total active power is\n\n\\[P=\\sqrt{3}\\,V_LI_L\\cos\\phi,\\]\n\nwhere \\(V_L\\) is line-to-line voltage and \\(I_L\\) is line current. Three-phase transmission supports nearly constant total instantaneous power for balanced sinusoidal loads. In practical electrical grids, power calculations must also account for unbalanced phases, harmonics, line losses, and changing demand. Energy meters integrate active power over time; they do not simply multiply a nominal voltage by a nominal current and the elapsed time."
    },
    {
      "heading": "Thermal power and thermodynamic conversion",
      "text": "Thermal power is the rate of energy transfer as heat, commonly written \\(\\dot Q\\). Heat is energy transferred because of a temperature difference, not a substance contained within a body. A hot object has internal energy and may transfer thermal power to cooler surroundings. Its temperature change depends on both the heat-transfer rate and its thermal properties. For a body of constant mass and approximately constant specific heat capacity,\n\n\\[P_{\\mathrm{net}}=mc\\frac{dT}{dt},\\]\n\nprovided that phase changes, mechanical work, and other energy transfers are negligible.\n\nConduction, convection, and radiation have different governing relationships. For one-dimensional steady conduction through a uniform slab,\n\n\\[\\dot Q=kA\\frac{T_{\\mathrm{hot}}-T_{\\mathrm{cold}}}{L},\\]\n\nwhere \\(k\\) is thermal conductivity, \\(A\\) is area, and \\(L\\) is thickness. Convection is often represented by \\(\\dot Q=hA(T_s-T_\\infty)\\), with a heat-transfer coefficient \\(h\\) determined by geometry, flow, and fluid properties. Net radiative exchange between a small gray surface and a large isothermal enclosure can be approximated by \\(\\dot Q=\\epsilon\\sigma A(T_s^4-T_{\\mathrm{sur}}^4)\\). The fourth-power dependence makes radiation especially important at high temperatures.\n\nThermal power does not specify temperature. A large heating system can transfer megawatts at moderate temperatures, while a tiny incandescent element can reach a high temperature with much less total power. Likewise, two bodies at the same temperature can have very different capacities to store energy. During melting or boiling, energy transfer may proceed without a temperature increase; the power then changes the amount of material in each phase through latent heat. For a single phase change at a steady rate, \\(\\dot Q=\\dot mL\\), where \\(L\\) is specific latent heat.\n\nA heat engine converts part of its incoming thermal power into mechanical or electrical output. If \\(\\dot Q_H\\) is absorbed from a hot source and \\(\\dot Q_C\\) is rejected to a cooler sink, steady cyclic operation gives\n\n\\[P_{\\mathrm{out}}=\\dot Q_H-\\dot Q_C, \\qquad \\eta=\\frac{P_{\\mathrm{out}}}{\\dot Q_H}.\\]\n\nThe second law of thermodynamics limits the conversion efficiency. An ideal reversible engine operating between reservoirs at absolute temperatures \\(T_H\\) and \\(T_C\\) has the Carnot efficiency \\(1-T_C/T_H\\). This is a limit on conversion fraction under specified conditions, not a direct prediction of output power, which also depends on energy-transfer rates.\n\nPower stations distinguish thermal power from electrical power for this reason. A plant receiving \\(3\\,\\mathrm{GW}\\) of thermal power and delivering \\(1\\,\\mathrm{GW}\\) of electricity has a thermal-to-electrical efficiency of one-third; the remaining energy leaves mainly as rejected heat. Heat pumps present a different accounting problem: electrical work moves heat rather than merely becoming heat. Their heating coefficient of performance can exceed one because the delivered thermal power includes both the electrical input and energy extracted from the surroundings. This does not violate energy conservation."
    },
    {
      "heading": "Power carried by fields, radiation, and sound",
      "text": "Energy can cross a region without matter flowing across it. In classical electromagnetism, the Poynting vector describes electromagnetic energy flux:\n\n\\[\\mathbf S=\\mathbf E\\times\\mathbf H.\\]\n\nIts units are watts per square metre. The electromagnetic power crossing a surface is\n\n\\[P=\\int_A\\mathbf S\\cdot d\\mathbf A.\\]\n\nFor time-varying fields, the instantaneous flux can fluctuate, and its time average is often the relevant measurable quantity. Poynting’s theorem relates field-energy storage, energy transport, and energy transfer to charged matter. It provides a local conservation law underlying the familiar circuit expression \\(VI\\).\n\nThis field description also clarifies electrical energy transport. In an ordinary conducting circuit, energy transfer is associated with the electric and magnetic fields in and around the conductors, not simply with electrons carrying packets of energy along the wire at their drift speed. The exact field pattern depends on conductor geometry and surroundings. Electromagnetic waves can carry power through empty space, while guided waves transport it along transmission lines and optical fibres. Absorption transfers some of that power to matter; reflection and transmission redistribute it among outgoing fields.\n\nRadiant power is total electromagnetic energy emitted, transmitted, or received per unit time, irrespective of wavelength. Irradiance is incident radiant power per unit area; radiant intensity is power per unit solid angle. These radiometric quantities differ from photometric quantities, which weight visible radiation according to a standardized model of human visual sensitivity. Thus, a lamp’s electrical wattage does not directly state its visible-light output. Its radiated spectrum and conversion efficiency matter, and much of the emitted power may lie outside the visible range.\n\nFor an isotropic source radiating total power \\(L\\) into transparent space, the irradiance at distance \\(r\\) is\n\n\\[F=\\frac{L}{4\\pi r^2}.\\]\n\nIn astronomy, total emitted power is called luminosity. The Sun’s luminosity is approximately \\(3.8\\times10^{26}\\,\\mathrm{W}\\). A nearly blackbody spherical emitter has \\(L=4\\pi R^2\\sigma T_{\\mathrm{eff}}^4\\), connecting luminosity, radius, and effective temperature through blackbody radiation. For monochromatic light, photon energy is \\(h\\nu\\), so a beam of power \\(P\\) has a mean photon arrival rate \\(P/(h\\nu)\\). The same optical power therefore corresponds to different photon rates at different frequencies.\n\nSound also carries power, but through mechanical disturbances in a medium. For a plane progressive sound wave, average intensity can be written \\(I=p_{\\mathrm{rms}}^2/(\\rho c)\\), where \\(p_{\\mathrm{rms}}\\) is acoustic pressure, \\(\\rho\\) is medium density, and \\(c\\) is sound speed. In general, acoustic intensity involves the time average of pressure multiplied by particle velocity. Sound power is the surface integral of outward acoustic intensity. It differs from sound pressure level at one location, which also depends on distance, reflections, directivity, and interference."
    },
    {
      "heading": "Efficiency, rated output, and operating constraints",
      "text": "A device’s input power, useful output power, and losses answer different questions. For a steady energy converter with a clearly defined useful output,\n\n\\[\\eta=\\frac{P_{\\mathrm{useful}}}{P_{\\mathrm{input}}}.\\]\n\nA motor receiving \\(10\\,\\mathrm{kW}\\) and supplying \\(9\\,\\mathrm{kW}\\) at its shaft has an efficiency of \\(90\\%\\), with \\(1\\,\\mathrm{kW}\\) appearing as losses, mainly heat. If an attached gearbox loses another \\(5\\%\\) of the mechanical input it receives, the combined efficiency is \\(0.90\\times0.95=0.855\\). Efficiencies multiply through successive conversion stages when the output of one stage is the input of the next.\n\nA rating specifies a permitted or expected operating condition rather than guaranteeing continuous output under all circumstances. A motor’s rated shaft power normally applies at specified voltage, frequency, speed, cooling, and duty. A power supply’s rating generally describes its available output, not its actual consumption at every moment. A loudspeaker’s power-handling figure, an amplifier’s output specification, and a radio transmitter’s radiated power refer to different positions in their respective energy chains. Comparing numerical wattages without identifying the measurement boundary can therefore be misleading.\n\nPeak power can greatly exceed average power. If an approximately rectangular pulse carries energy \\(E_p\\) during a duration \\(\\tau\\), its power during the pulse is approximately \\(E_p/\\tau\\). At a repetition frequency \\(f\\), its average power is \\(E_pf\\). A laser delivering \\(1\\,\\mathrm{mJ}\\) in \\(1\\,\\mathrm{ns}\\) has approximately \\(1\\,\\mathrm{MW}\\) of pulse power; at \\(1\\,\\mathrm{kHz}\\), its average output is only \\(1\\,\\mathrm{W}\\). Real pulse shapes require more careful definitions of duration and peak value, but the distinction between peak and average remains fundamental.\n\nSpecific power, expressed in watts per kilogram, describes power relative to mass. It matters in aircraft propulsion, portable equipment, and vehicle systems. Power density can instead refer to watts per unit volume or area; the denominator must be explicit. These quantities are distinct from energy density. A storage device may hold substantial energy but release it slowly, or deliver high power for only a short time. For a constant output, the ideal discharge duration is \\(t=E/P\\), although real devices are constrained by voltage, temperature, chemistry, and allowable operating limits.\n\nThermal management often sets the sustainable power of machinery and electronics. Losses raise temperature, which can increase resistance, alter material properties, or exceed component limits. Cooling permits higher continuous loading by removing heat, but cooling equipment itself may consume power. Power plants also distinguish nameplate capacity from time-averaged production. Their capacity factor is the energy actually generated over an interval divided by the energy that continuous operation at rated capacity would have produced. It is not the same as thermodynamic efficiency: downtime, resource availability, and dispatch can reduce capacity factor without changing conversion efficiency during operation."
    },
    {
      "heading": "Measurement methods, uncertainty, and physical scales",
      "text": "Power measurements usually infer energy-transfer rate from other measurable quantities. Mechanical shaft power is commonly determined from torque and rotational speed, using a dynamometer or an instrumented shaft. The torque may be obtained from a calibrated force acting through a known lever arm. Measuring both quantities under the same operating conditions is important because torque and speed may fluctuate together. In transient tests, the power used to accelerate rotating parts must also be distinguished from the power delivered to an external load.\n\nElectrical wattmeters measure voltage and current and determine their instantaneous product or its appropriate average. For alternating current, multiplying separate rms readings gives apparent power, not necessarily active power. Accurate active-power measurement requires correct phase information and sufficient bandwidth to capture relevant waveform components. At radio and microwave frequencies, detectors, directional couplers, and thermal power sensors are used. Reflections in transmission lines make it necessary to distinguish forward power, reflected power, and net power delivered to a load.\n\nThermal power can be measured by calorimetry. In a flowing coolant under approximately steady conditions,\n\n\\[P\\approx\\dot m c_p(T_{\\mathrm{out}}-T_{\\mathrm{in}}),\\]\n\nwhen pressure effects, phase changes, and heat leakage are negligible. A more general formulation uses the difference in specific enthalpy between inlet and outlet. Optical power meters may use photodiodes, whose current depends on wavelength-dependent responsivity, or thermal absorbers that respond to deposited energy. For pulsed sources, a sensor’s response time determines whether it measures pulse energy, average power, or the detailed waveform.\n\nMeasurement uncertainty arises from sensor calibration, timing, phase errors, heat leakage, alignment, finite bandwidth, and assumptions in the measurement model. For a product \\(P=VI\\) with independent small uncertainties, a useful approximation is\n\n\\[\\left(\\frac{u(P)}{P}\\right)^2 \\approx \\left(\\frac{u(V)}{V}\\right)^2+ \\left(\\frac{u(I)}{I}\\right)^2.\\]\n\nCorrelations require additional terms. In sinusoidal AC measurements, uncertainty in phase becomes especially important when the power factor is small. Calibration and metrological traceability connect practical instruments to recognized measurement standards, while a complete specification also identifies averaging time, operating conditions, and the boundary across which power is measured.\n\nPower spans an enormous range across physical systems. A \\(1\\,\\mathrm{eV}\\) energy-transfer event occurring once per second corresponds to about \\(1.60\\times10^{-19}\\,\\mathrm{W}\\) as a long-time average. Human metabolic power at rest is of order \\(10^2\\,\\mathrm{W}\\), mostly appearing as heat; sustained external mechanical output is only part of metabolic energy use. Household appliances commonly operate from a few watts to several kilowatts, large generating units reach the gigawatt scale, and stars radiate many orders of magnitude more. At every scale, the numerical value becomes meaningful only when its time interval, transfer mechanism, and system boundary are identified."
    }
  ],
  "links": [
    "energy",
    "work-physics",
    "james-watt",
    "first-law-of-thermodynamics",
    "international-system-of-units",
    "joule",
    "second",
    "horsepower",
    "james-prescott-joule",
    "force",
    "momentum",
    "kinetic-energy",
    "torque",
    "inertial-reference-frame",
    "pressure",
    "electric-current",
    "electric-charge",
    "direct-current",
    "ohms-law",
    "joule-heating",
    "alternating-current",
    "power-factor",
    "electrical-grid",
    "heat",
    "thermal-conductivity",
    "latent-heat",
    "second-law-of-thermodynamics",
    "carnot-cycle",
    "electromagnetism",
    "poynting-vector",
    "astronomy",
    "blackbody-radiation",
    "calorimetry",
    "enthalpy",
    "measurement-uncertainty",
    "calibration",
    "metrological-traceability"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}