{
  "id": "ohm",
  "title": "Ohm",
  "lang": "en",
  "source_lang": "en",
  "summary": "The ohm (Ω) is the SI derived unit of electrical resistance, equal to one volt per ampere and also used for impedance and reactance.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [],
  "generated_at": "2026-11-03",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/ohm/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/ohm/",
      "json": "https://aiwiki.page/zh/ohm.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "The ohm, symbol Ω, is the coherent derived unit of electrical resistance in the International System of Units (SI). One ohm is the resistance of a conductor through which an electric current of one ampere flows when a potential difference of one volt is maintained across it. The unit is named after the German physicist Georg Simon Ohm, whose investigations established the relationship between voltage, current, and resistance now known as Ohm’s law. The ohm also expresses electrical impedance and reactance."
    },
    {
      "heading": "Definition and dimensions",
      "text": "The ohm is defined by\n\n\\[1\\,\\Omega = 1\\,\\frac{\\mathrm{V}}{\\mathrm{A}},\\]\n\nwhere V denotes the volt and A denotes the ampere. In SI base units,\n\n\\[1\\,\\Omega = 1\\,\\mathrm{kg\\,m^2\\,s^{-3}\\,A^{-2}}.\\]\n\nThus its physical dimension is mass times length squared divided by time cubed and current squared.\n\nFor a two-terminal element with potential difference \\(V\\) and current \\(I\\), its resistance at a specified operating point is\n\n\\[R=\\frac{V}{I}.\\]\n\nFor example, a resistor carrying \\(0.5\\,\\mathrm{A}\\) under an applied voltage of \\(6\\,\\mathrm{V}\\) has a resistance of \\(12\\,\\Omega\\).\n\nThis ratio alone does not establish Ohm’s law. An ohmic element has a voltage proportional to current when relevant physical conditions, especially temperature, remain constant. A nonlinear element may instead have a resistance \\(V/I\\) that varies with its operating point. Its differential resistance,\n\n\\[r=\\frac{\\mathrm{d}V}{\\mathrm{d}I},\\]\n\nis also expressed in ohms but need not equal \\(V/I\\).\n\nThe reciprocal of resistance is conductance:\n\n\\[G=\\frac{1}{R}.\\]\n\nIts SI unit is the siemens, symbol S, with \\(1\\,\\mathrm{S}=1\\,\\Omega^{-1}\\)."
    },
    {
      "heading": "Symbol, prefixes, and notation",
      "text": "The symbol Ω is the uppercase Greek letter omega. As with other SI unit symbols, it is not pluralized: “10 ohms” is written \\(10\\,\\Omega\\), not “10 Ωs.” The unit name is lowercase in ordinary prose, despite its derivation from a personal name.\n\nCommon multiples and submultiples include:\n\nUnit | Symbol | Value\nMicroohm | µΩ | \\(10^{-6}\\,\\Omega\\)\nMilliohm | mΩ | \\(10^{-3}\\,\\Omega\\)\nKilohm | kΩ | \\(10^3\\,\\Omega\\)\nMegohm | MΩ | \\(10^6\\,\\Omega\\)\nGigohm | GΩ | \\(10^9\\,\\Omega\\)\n\nCapitalization matters: mΩ and MΩ differ by a factor of one billion.\n\nCircuit diagrams and component markings sometimes substitute a letter for the decimal separator. For example, “4R7” denotes \\(4.7\\,\\Omega\\), while “4k7” denotes \\(4.7\\,\\mathrm{k}\\Omega\\). These are engineering marking conventions rather than standard SI quantity notation."
    },
    {
      "heading": "Resistance, resistivity, and geometry",
      "text": "Resistance characterizes a particular object or electrical path. Resistivity characterizes a material under specified conditions. For a uniform conductor of length \\(L\\), cross-sectional area \\(A\\), and resistivity \\(\\rho\\),\n\n\\[R=\\rho\\frac{L}{A}.\\]\n\nConsequently, resistivity is expressed in ohm metres, \\(\\Omega\\,\\mathrm{m}\\), not simply ohms. A longer wire has greater resistance than a shorter wire of the same material and cross section; a thicker wire has lower resistance.\n\nResistance also depends on temperature, material composition, mechanical strain, and other physical conditions. A precision resistance value therefore requires more than a nominal number of ohms: its measurement conditions and measurement uncertainty must also be specified.\n\nFor thin conducting films, sheet resistance is commonly reported in “ohms per square,” written Ω/□. This notation describes a geometry-independent property of a uniform film: the resistance measured between opposite edges of a square is independent of that square’s size under ideal conditions. “Per square” is a geometrical convention, not an additional physical dimension."
    },
    {
      "heading": "Impedance and reactance",
      "text": "In alternating-current circuits, voltage and current can differ in phase as well as amplitude. Their relationship is described by electrical impedance, usually written\n\n\\[Z=R+jX,\\]\n\nwhere \\(R\\) is resistance, \\(X\\) is reactance, and \\(j^2=-1\\). Impedance, resistance, and reactance all have the unit ohm.\n\nFor ideal inductors and capacitors in sinusoidal steady state,\n\n\\[Z_L=j\\omega L, \\qquad Z_C=\\frac{1}{j\\omega C},\\]\n\nwhere \\(\\omega\\) is angular frequency, \\(L\\) is inductance, and \\(C\\) is capacitance. Their impedances therefore depend on frequency.\n\nHaving the same unit does not make resistance and reactance physically interchangeable. Resistance is associated with energy dissipation, whereas ideal reactance represents reversible energy storage and return. An impedance specified as “50 Ω” may describe a purely resistive load or a transmission line’s characteristic impedance; its interpretation depends on context and frequency."
    },
    {
      "heading": "Measurement and practical standards",
      "text": "Resistance is measured using ohmmeters, multimeters, bridge circuits, or instruments that apply a known current and measure the resulting voltage. Precision measurements are part of electrical metrology.\n\nDifferent resistance ranges require different techniques:\n\n- Low resistance: Lead and contact resistances can be comparable to the quantity being measured. Four-terminal measurements separate current-carrying connections from voltage-sensing connections, greatly reducing these contributions.\n- High resistance: Leakage currents through insulation, surface contamination, and humidity can affect results. Guarding and suitable insulation help distinguish the intended current path from unwanted paths.\n- Precision resistance: Measuring current can warm a resistor through Joule heating, changing its resistance. Temperature control, limited measuring power, and calibration against suitable standards are therefore important.\n\nA standard resistor provides a practical reference value, but its resistance is not perfectly invariant. Temperature, ageing, applied power, and sometimes frequency affect its value.\n\nQuantum realization\n\nThe quantum Hall effect provides a highly reproducible basis for resistance standards. On an integer quantum Hall plateau, the magnitude of the Hall resistance is\n\n\\[R_H=\\frac{h}{i e^2}=\\frac{R_K}{i},\\]\n\nwhere \\(i\\) is a positive integer, \\(h\\) is the Planck constant, \\(e\\) is the elementary charge, and \\(R_K=h/e^2\\) is the von Klitzing constant.\n\nSince the SI revision that took effect on 20 May 2019, \\(h\\) and \\(e\\) have exact fixed numerical values. Accordingly, \\(R_K\\) has an exact value determined by those constants, approximately\n\n\\[R_K\\approx25\\,812.80745\\,\\Omega.\\]\n\nA physical realization still has measurement uncertainty: exact defining constants do not make an experimental apparatus error-free. Quantum Hall standards establish metrological traceability for working resistance standards through comparison measurements."
    },
    {
      "heading": "Historical development",
      "text": "Ohm published his mathematical treatment of electrical circuits in 1827. As telegraph networks expanded during the nineteenth century, resistance measurements became commercially and scientifically important, creating demand for reproducible units and standards.\n\nBritish Association work in the 1860s helped establish practical resistance standards. An international electrical congress in Paris adopted the name ohm in 1881. Late nineteenth- and early twentieth-century systems used mercury-column specifications to make resistance units reproducible across laboratories.\n\nThese material realizations were eventually superseded by units tied more consistently to the metre–kilogram–second electrical system. The international electrical units were replaced by absolute electrical units in 1948, and the ohm became part of the SI when that system was established in 1960.\n\nFrom 1990, many national laboratories used the internationally agreed conventional value \\(R_{K-90}=25\\,812.807\\,\\Omega\\) to maintain practical resistance standards based on the quantum Hall effect. That conventional scale was distinct from the SI realization then in force. The 2019 SI revision removed the need for this separate conventional value by fixing \\(h\\) and \\(e\\) directly."
    }
  ],
  "links": [
    "electrical-resistance",
    "international-system-of-units",
    "electric-current",
    "georg-simon-ohm",
    "volt",
    "ampere",
    "ohms-law",
    "electrical-resistivity",
    "temperature",
    "measurement-uncertainty",
    "alternating-current",
    "electrical-impedance",
    "capacitance",
    "metrology",
    "joule-heating",
    "calibration",
    "quantum-hall-effect",
    "planck-constant",
    "elementary-charge",
    "metrological-traceability"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}