      "heading": "",
      "text": "Luminous flux is a measure of the amount of light emitted, transmitted, or received per unit time, weighted according to a standardized model of human visual sensitivity. Its symbol is usually \\(\\Phi_v\\), and its SI unit is the lumen (lm). Unlike radiant flux, which measures the physical power of electromagnetic radiation, luminous flux accounts for the fact that different wavelengths contribute differently to human vision. It is widely used to specify the light output of lamps and luminaires."
    },
    {
      "heading": "Physical and visual basis",
      "text": "Luminous flux belongs to photometry, the measurement of light using standardized visual-response functions. Its physical counterpart is radiant flux, measured in watts, which describes the rate at which electromagnetic radiation carries energy without weighting it for visual sensitivity.\n\nThe distinction matters because the human eye does not respond equally to all wavelengths. Under bright viewing conditions, sensitivity is greatest in the yellow-green region, near 555 nanometres, and decreases toward the red and violet ends of the visible spectrum. Infrared and ultraviolet radiation contribute essentially nothing to conventional luminous flux, even though they can carry substantial radiant power.\n\nConsequently, two sources with identical radiant flux can have very different luminous fluxes. Conversely, two lamps with identical lumen ratings can have different spectra, colors, electrical power consumption, and visual effects.\n\nLuminous flux is a standardized physical quantity, not a direct measurement of an individual's subjective experience of brightness."
    },
    {
      "heading": "Spectral definition",
      "text": "For conventional photopic photometry, representing vision under well-lit conditions, luminous flux is calculated from the spectral radiant flux:\n\n\\[\\Phi_v = K_m \\int_0^\\infty V(\\lambda)\\, \\Phi_{e,\\lambda}(\\lambda)\\, \\mathrm{d}\\lambda.\\]\n\nHere:\n\n- \\(\\Phi_v\\) is luminous flux, in lumens.\n- \\(\\Phi_{e,\\lambda}\\) is spectral radiant flux per unit wavelength.\n- \\(V(\\lambda)\\) is the standardized photopic spectral luminous efficiency function.\n- \\(K_m\\) is the maximum photopic luminous efficacy of radiation, approximately \\(683\\ \\mathrm{lm\\,W^{-1}}\\).\n\nThe wavelength units used for spectral radiant flux and the integration interval must be consistent. The function \\(V(\\lambda)\\) is dimensionless and normalized to a maximum of one.\n\nFor monochromatic radiation, the expression simplifies to\n\n\\[\\Phi_v = K_m V(\\lambda)\\Phi_e.\\]\n\nThus, one watt of radiant flux near the maximum of photopic sensitivity corresponds to approximately 683 lumens. At wavelengths where visual sensitivity is lower, the same radiant power produces fewer lumens.\n\nExact SI reference\n\nThe SI fixes the luminous efficacy of monochromatic radiation of frequency \\(540\\times10^{12}\\ \\mathrm{Hz}\\) at exactly\n\n\\[K_{\\mathrm{cd}}=683\\ \\mathrm{lm\\,W^{-1}}.\\]\n\nThis frequency corresponds to a vacuum wavelength of approximately 555.17 nanometres. The exact reference is specified by frequency, rather than by a rounded wavelength. It underlies the definition of the candela and therefore the lumen."
    },
    {
      "heading": "Relationship to other photometric quantities",
      "text": "Several quantities describe different aspects of light and should not be confused with luminous flux.\n\nQuantity | Meaning | SI unit\nLuminous flux | Total visually weighted radiant power | lumen, lm\nLuminous intensity | Luminous flux per unit solid angle in a specified direction | candela, cd\nIlluminance | Luminous flux incident per unit area | lux, lx\nLuminance | Directional luminous intensity per unit projected area | candela per square metre, \\(\\mathrm{cd\\,m^{-2}}\\)\n\nLuminous intensity and angular distribution\n\nLuminous intensity describes how flux is distributed by direction:\n\n\\[I_v=\\frac{\\mathrm{d}\\Phi_v}{\\mathrm{d}\\Omega},\\]\n\nwhere \\(\\Omega\\) is solid angle, measured in steradians. Accordingly,\n\n\\[1\\ \\mathrm{lm}=1\\ \\mathrm{cd\\,sr}.\\]\n\nTotal luminous flux is obtained by integrating intensity over the relevant directions:\n\n\\[\\Phi_v=\\int I_v\\,\\mathrm{d}\\Omega.\\]\n\nAn ideal source emitting uniformly in every direction with an intensity of one candela has a total luminous flux of \\(4\\pi\\) lumens.\n\nA narrow-beam spotlight and a diffuse lamp can therefore emit the same total lumens while having very different peak intensities.\n\nIlluminance\n\nIlluminance is the density of incident luminous flux on a surface:\n\n\\[E_v=\\frac{\\mathrm{d}\\Phi_v}{\\mathrm{d}A}.\\]\n\nOne lux equals one lumen per square metre. If 1,000 lumens are distributed uniformly over an area of 10 square metres, the illuminance is 100 lux.\n\nFor a point-like source illuminating a surface perpendicular to the incident rays, with negligible intervening losses,\n\n\\[E_v=\\frac{I_v}{r^2}.\\]\n\nAt oblique incidence, a cosine factor accounts for the surface orientation. A lamp's lumen rating alone therefore does not determine the illuminance at a particular location.\n\nLuminance\n\nLuminance describes light traveling in a specified direction from a surface per unit projected area and solid angle. It is particularly important for displays, visible emitting surfaces, and reflected light. Sources with the same total flux can have very different luminances if their emitting areas or angular distributions differ."
    },
    {
      "heading": "Measurement",
      "text": "Luminous flux is commonly measured using an integrating sphere or a goniophotometer.\n\nAn integrating sphere has a highly reflective, diffusely reflecting interior. Multiple reflections make the detector response approximately proportional to the total flux introduced into the sphere. Practical measurements require corrections for effects such as light absorbed by the source and its supports, nonuniform sphere response, and differences between the test source and the reference source.\n\nA goniophotometer measures luminous intensity over many directions. Integrating these measurements over solid angle gives the total luminous flux and also provides the angular distribution needed for lighting calculations.\n\nSpectral measurements offer another route: measured spectral radiant flux is weighted by the standard visual-response function and integrated. This is especially useful when detector sensitivity does not precisely match \\(V(\\lambda)\\).\n\nReliable measurements depend on calibration, controlled operating conditions, and a stated measurement uncertainty. Source output can vary with temperature, electrical operating conditions, warm-up time, and aging."
    },
    {
      "heading": "Luminous efficacy and lighting applications",
      "text": "Luminous efficacy expresses luminous flux per unit power, but the power denominator must be specified.\n\nLuminous efficacy of radiation relates luminous flux to radiant flux:\n\n\\[K=\\frac{\\Phi_v}{\\Phi_e}.\\]\n\nElectrical luminous efficacy relates the light output of a lamp or lighting system to its electrical input power:\n\n\\[\\eta_v=\\frac{\\Phi_v}{P_{\\mathrm{electrical}}}.\\]\n\nBoth are expressed in lumens per watt, but they describe different properties. Electrical luminous efficacy includes energy-conversion losses; a system-level value may also include driver and optical losses.\n\nLumen ratings allow light output to be compared independently of electrical wattage. Nevertheless, equal lumens do not imply equal lighting performance. Beam distribution, optical losses, room geometry, surface reflectance, and mounting position determine how much light reaches a task.\n\nBare-source flux also differs from luminaire output: reflectors, lenses, diffusers, and housings can absorb or redirect part of the light."
    },
    {
      "heading": "Standardization and limitations",
      "text": "The international adoption of the photopic \\(V(\\lambda)\\) function in 1924 established a common basis for comparing visible radiation. The 1979 candela definition connected photometry directly to radiant power at a specified optical frequency; the current SI expresses that relationship through the fixed value of \\(K_{\\mathrm{cd}}\\).\n\nConventional lumen ratings primarily represent photopic vision. Under very low illumination, rod-mediated vision has a different spectral sensitivity, represented by a scotopic weighting function with a peak near 507 nanometres. Intermediate, mesopic conditions involve both rod and cone responses. Photopic lumens therefore do not fully predict visual performance across all lighting levels.\n\nLuminous flux also does not specify color rendering, glare, flicker, spatial uniformity, or subjective brightness. Nor is it an adequate measure of ultraviolet exposure, infrared heating, or other biological effects of radiation, which require different quantities and spectral weightings."
    }
  ],