  "id": "infrared",
  "title": "Infrared",
  "lang": "en",
  "source_lang": "en",
  "summary": "Infrared is electromagnetic radiation beyond visible red light, central to thermal emission, molecular spectroscopy, imaging, astronomy, and optical communications.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Infrared radiation",
    "IR radiation",
    "infrared light"
  ],
  "generated_at": "2026-11-03",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/infrared/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/infrared/",
      "json": "https://aiwiki.page/zh/infrared.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "Infrared is electromagnetic radiation with wavelengths longer than those of visible red light and shorter than those conventionally assigned to microwaves. Its approximate range extends from 780 nanometres to 1 millimetre, although boundaries and subdivisions vary among scientific and technical fields. Infrared is invisible to ordinary human vision, but it interacts strongly with many materials and carries much of the radiation emitted by objects at everyday temperatures.\n\nInfrared observations reveal information that visible light alone cannot provide: the vibrational structure of molecules, the temperatures of surfaces, stars obscured by interstellar dust, and the composition of planetary atmospheres. Infrared technologies underpin thermal cameras, many chemical instruments, fibre-optic communications, remote controls, industrial heating, and environmental monitoring. Understanding these uses requires distinguishing infrared radiation from heat itself, and distinguishing radiation reflected from a source from radiation emitted by an object."
    },
    {
      "heading": "Spectral range and physical nature",
      "text": "Infrared occupies a broad region of the electromagnetic spectrum, spanning more than three orders of magnitude in wavelength. Its short-wavelength boundary is not an abrupt physical discontinuity: human visual sensitivity declines gradually at the red end of the spectrum. A boundary near 780 nanometres is widely used in optical standards, while astronomy and other disciplines sometimes begin infrared coverage near 700 nanometres. At the long-wavelength end, infrared merges into the submillimetre and microwave regions, whose terminology also depends on the observing technique.\n\nLike all electromagnetic waves in a vacuum, infrared propagates at the speed of light. Wavelength \\(\\lambda\\), frequency \\(\\nu\\), and photon energy \\(E\\) are related by\n\n\\[c=\\lambda\\nu,\\qquad E=h\\nu=\\frac{hc}{\\lambda},\\]\n\nwhere \\(h\\) is the Planck constant. Wavelengths of 780 nanometres and 1 millimetre correspond approximately to frequencies of 384 terahertz and 300 gigahertz. Their photon energies are about 1.59 and 0.00124 electronvolts, respectively. These energies are generally below those required for single-photon ionization of ordinary atoms and molecules, but they coincide with many molecular, lattice, and low-energy electronic excitations.\n\nSeveral classification systems coexist. One common optical scheme defines near-infrared as 0.78–3 micrometres, mid-infrared as 3–50 micrometres, and far-infrared as 50–1,000 micrometres. Radiation-protection terminology instead divides the range into IR-A, approximately 780–1,400 nanometres; IR-B, 1.4–3 micrometres; and IR-C, 3 micrometres–1 millimetre. Astronomical near-, mid-, and far-infrared boundaries differ again. Consequently, a wavelength interval is more informative than a band name alone.\n\nImaging engineers frequently use near-infrared, short-wave infrared, mid-wave infrared, and long-wave infrared. Typical instrument ranges include roughly 0.9–1.7 micrometres for many short-wave cameras, 3–5 micrometres for mid-wave thermal systems, and 8–14 micrometres for long-wave thermal systems. These divisions reflect detector sensitivity and atmospheric transmission rather than separate kinds of radiation.\n\nInfrared also exhibits reflection, refraction, diffraction, interference, and polarization. Its comparatively long wavelengths influence instrument design. For the same aperture diameter, an infrared telescope has poorer diffraction-limited angular resolution than a visible-light telescope. Conversely, infrared wavelengths can interact with structures and molecular motions that are difficult to investigate at visible wavelengths. Neither invisibility nor warmth defines the radiation: wavelength does."
    },
    {
      "heading": "Discovery and development",
      "text": "The discovery of infrared is associated with William Herschel’s experiments in 1800. Herschel passed sunlight through a prism and placed thermometers in different parts of the resulting spectrum to compare their heating effects. A thermometer positioned beyond the visible red end registered a temperature rise, demonstrating that solar radiation extended into a region invisible to the eye. He described these observations in papers presented to the Royal Society. His experiment established the existence of radiation beyond the visible spectrum before its electromagnetic nature was understood.\n\nEarly investigation depended on detecting very small heating effects. Thermopiles, which combine multiple thermoelectric junctions, made it possible to measure weaker radiation than ordinary thermometers could resolve. Macedonio Melloni used such instruments during the 1830s to study the transmission of radiant heat through different materials. His work helped show that substances transparent to visible light need not be transparent to infrared, and that transmission depends strongly on wavelength.\n\nIn the later nineteenth century, Samuel Pierpont Langley developed the bolometer, a detector that measures radiation through the change in electrical resistance caused by heating. Introduced around 1880, it enabled increasingly detailed measurements of the solar infrared spectrum. Meanwhile, electromagnetic theory and the study of blackbody radiation provided a unified explanation of visible and invisible radiation. Max Planck’s radiation law of 1900 accurately described the spectrum of a body in thermal equilibrium and became a foundation of quantum mechanics.\n\nTwentieth-century development shifted infrared measurement from laboratory experiments toward imaging and electronic detection. Lead-salt photoconductors and later semiconductor detectors converted infrared radiation directly into electrical signals. Research associated with World War II accelerated work on night observation, target detection, and infrared optics. Subsequent detector materials, including indium antimonide and mercury cadmium telluride, extended sensitivity and enabled focal-plane arrays with many individually read pixels.\n\nInfrared spectroscopy also changed substantially with the adoption of interferometric instruments and digital computation. Fourier-transform instruments became prominent in the second half of the twentieth century because they could record broad spectral information efficiently. In imaging, the development of uncooled microbolometer arrays helped make thermal cameras smaller and less costly than systems requiring cryogenic detectors.\n\nSpaceflight opened infrared wavelengths inaccessible from the ground. The Infrared Astronomical Satellite, launched in 1983, carried out a pioneering space-based infrared sky survey. Later observatories included the Spitzer Space Telescope, launched in 2003, and Herschel, launched in 2009. The James Webb Space Telescope, launched in 2021, extended high-sensitivity infrared imaging and spectroscopy through a large, cold observatory designed to suppress its own thermal background."
    },
    {
      "heading": "Thermal emission and interactions with matter",
      "text": "Infrared is often called “heat radiation,” but this expression can obscure an important distinction. Heat is energy transferred because of a temperature difference; infrared is one range of electromagnetic radiation. Infrared may transfer energy between objects, but it can also be reflected, transmitted, or generated by nonthermal processes. Conversely, sufficiently hot objects emit substantial thermal radiation in visible and ultraviolet wavelengths as well as infrared.\n\nThe thermal spectrum of an ideal blackbody is described by Planck’s law. In wavelength form, its spectral radiance is\n\n\\[B_\\lambda(T)= \\frac{2hc^2}{\\lambda^5} \\frac{1}{\\exp\\!\\left(\\frac{hc}{\\lambda k_{\\mathrm B}T}\\right)-1},\\]\n\nwhere \\(T\\) is absolute temperature and \\(k_{\\mathrm B}\\) is the Boltzmann constant. The wavelength at which this expression peaks follows Wien’s displacement law:\n\n\\[\\lambda_{\\max}T\\approx 2.898\\times10^{-3}\\ \\mathrm{m\\,K}.\\]\n\nA 300-kelvin blackbody therefore has its wavelength-spectrum peak near 9.7 micrometres. A 5,800-kelvin blackbody peaks near 0.50 micrometres, in the visible region, while still emitting considerable infrared radiation.\n\nTotal blackbody emission per unit area follows the Stefan–Boltzmann law, \\(M=\\sigma T^4\\). Real surfaces are described by emissivity, which can vary with wavelength, direction, temperature, and surface condition. Kirchhoff’s law of thermal radiation relates emissivity to absorptivity under thermal-equilibrium conditions: a good absorber at a given wavelength and direction is also a good emitter there. A polished metal surface may therefore emit little infrared while strongly reflecting radiation from surrounding objects.\n\nAt the microscopic level, infrared absorption occurs when the radiation couples to an allowed excitation. In a molecule, many mid-infrared bands arise from changes in vibrational state, often accompanied by rotational structure. A vibration is infrared-active when it changes the molecular electric dipole moment. Some vibrations of symmetric molecules are consequently weak or absent in infrared spectra even though other techniques detect them. Near-infrared molecular absorption commonly involves overtones and combinations of fundamental vibrations.\n\nIn solids, infrared can excite lattice vibrations, or phonons, as well as charge-carrier motion and electronic transitions. Semiconductor absorption depends partly on the band gap: photons above an appropriate absorption threshold can generate mobile charge carriers. Metals respond strongly through their conduction electrons and are often highly reflective in much of the infrared.\n\nTransmission is therefore material- and wavelength-specific. Ordinary window glass transmits visible light and portions of the near-infrared but is effectively opaque over much of the thermal infrared. Water also has strong infrared absorption bands. Statements that infrared “passes through” a material are meaningful only when the wavelength, thickness, and physical condition of that material are specified."
    },
    {
      "heading": "Atmospheric transmission and climate",
      "text": "The atmosphere of Earth is neither uniformly transparent nor uniformly opaque to infrared. Water vapour, carbon dioxide, methane, ozone, and other gases absorb and emit at characteristic wavelengths. Molecular absorption lines combine into bands whose widths and strengths depend on temperature, gas concentration, and pressure. Pressure broadening results from molecular collisions, while thermal motion contributes Doppler broadening. Between strong absorption bands lie relatively transparent atmospheric windows.\n\nTwo important windows for terrestrial thermal imaging occur around 3–5 and 8–14 micrometres, although their exact usefulness depends on humidity, path length, and observing conditions. The long-wave window is interrupted by ozone absorption near 9.6 micrometres, and transmission declines near strong water-vapour and carbon-dioxide bands. For this reason, camera specifications often quote a detector band narrower than the full nominal window. Clouds and fog can severely limit infrared transmission, especially when droplets absorb, emit, and scatter radiation along the viewing path.\n\nInfrared plays a central role in the Earth’s energy budget. The Sun supplies energy mainly at visible and near-infrared wavelengths. Earth, with much lower surface and atmospheric temperatures, emits chiefly in the thermal infrared. In approximate planetary energy balance, absorbed solar energy is matched by outgoing thermal radiation at the top of the atmosphere. The effective radiating temperature associated with Earth’s outgoing flux is about 255 kelvin, lower than its global mean surface temperature of roughly 288 kelvin.\n\nThe greenhouse effect arises because atmospheric gases and clouds interact with outgoing infrared radiation. They absorb radiation in some spectral regions and emit radiation both upward and downward. In many absorbing bands, radiation escaping to space originates from atmospheric layers rather than directly from the surface. Increasing the abundance of an absorbing gas can change the altitude and temperature from which radiation escapes, altering the outgoing energy flux before the climate system adjusts.\n\nCarbon dioxide has a particularly important band near 15 micrometres. Its climatic influence cannot be assessed merely by noting that the centre of a strong absorption band is already opaque: the band wings, vertical atmospheric structure, and wavelength-dependent emission remain important. Water vapour absorbs broadly and acts as a major climate feedback, because its atmospheric abundance responds strongly to temperature. Clouds affect both incoming sunlight and outgoing infrared radiation, with effects that depend on their height, thickness, and microphysical properties.\n\nSatellite infrared sounders exploit these same absorption mechanisms to infer atmospheric temperature, humidity, and trace-gas distributions. Different spectral channels sample different combinations of altitude and atmospheric composition. Such retrievals require radiative transfer calculations rather than a simple conversion from observed brightness to local temperature."
    },
    {
      "heading": "Sources, optical components, and detectors",
      "text": "Infrared sources fall into thermal and nonthermal categories. Electrically heated filaments, ceramic emitters, and silicon-carbide elements produce broad spectra determined largely by their temperature and emissivity. Tungsten lamps emit strongly in the near-infrared, while silicon-carbide “Globar” sources are widely used in laboratory mid-infrared instruments. Thermal sources are useful when a broad wavelength range is required, but only part of their output falls within any narrow measurement band.\n\nNonthermal sources include light-emitting diodes and lasers. Near-infrared semiconductor emitters commonly use materials based on gallium arsenide or indium phosphide. Carbon-dioxide lasers emit strongly near 10.6 micrometres and are used in processing materials. Quantum-cascade lasers, first demonstrated in 1994, produce radiation through engineered electronic transitions within semiconductor layered structures rather than ordinary electron–hole recombination across a bulk band gap. They provide compact, spectrally selective mid-infrared sources for sensing and spectroscopy.\n\nOptical materials must be chosen for the relevant wavelengths. Fused silica serves many near-infrared applications but is unsuitable across much of the mid-infrared. Calcium fluoride, zinc selenide, germanium, and other materials provide transmission in different infrared intervals. Sodium chloride and potassium bromide have long been used for spectroscopic windows and sample preparation, although their sensitivity to moisture complicates handling. Reflective optics avoid bulk transmission limits and reduce chromatic aberration, but mirror coatings and surface quality remain important.\n\nInfrared detectors are commonly divided into photon detectors and thermal detectors. Photon detectors absorb radiation and create or redistribute electrical charge. Silicon devices are sensitive only to approximately 1.1 micrometres, whereas standard indium gallium arsenide detectors commonly cover about 0.9–1.7 micrometres. Indium antimonide and mercury cadmium telluride extend detection into longer wavelengths; the latter’s operating range can be adjusted through composition. Many mid- and long-wave photon detectors require cooling to suppress thermally generated charge and other noise.\n\nThermal detectors respond to absorbed energy through a temperature-dependent property. Bolometers measure changes in electrical resistance; thermopiles measure thermoelectric voltage; pyroelectric detectors respond to changes in polarization during temperature variation. Uncooled thermal cameras commonly employ microbolometer arrays made from materials such as vanadium oxide or amorphous silicon. Their pixels are thermally isolated so that small amounts of absorbed radiation produce measurable temperature changes.\n\nDetector performance is not characterized by sensitivity alone. Spectral response, response time, pixel size, noise, dynamic range, and stability all affect measurement quality. Optical backgrounds can dominate weak signals, especially at longer wavelengths. Reliable instruments consequently require careful calibration, temperature control, suppression of stray radiation, and a defined relationship between detector output and incident radiance."
    },
    {
      "heading": "Molecular spectroscopy and chemical analysis",
      "text": "Infrared spectroscopy identifies and characterizes substances by measuring their wavelength-dependent absorption or emission. Its central strength is the relationship between molecular structure and vibrational frequency. Bond stiffness, atomic masses, molecular geometry, and interactions with the surroundings all influence the spectrum. In the harmonic approximation, a simple vibration has a frequency proportional to \\(\\sqrt{k/\\mu}\\), where \\(k\\) is an effective force constant and \\(\\mu\\) a reduced mass. Real molecules also exhibit anharmonicity and coupling among vibrations.\n\nSpectra are often expressed in wavenumber, \\(\\tilde{\\nu}=1/\\lambda\\), conventionally measured in reciprocal centimetres. The widely used mid-infrared analytical interval of 4,000–400 \\(\\mathrm{cm^{-1}}\\) corresponds to wavelengths of 2.5–25 micrometres. Carbonyl groups commonly give strong absorption near 1,700 \\(\\mathrm{cm^{-1}}\\), although the precise position depends on chemical environment. O–H stretching often appears broadly in the 3,200–3,600 \\(\\mathrm{cm^{-1}}\\) region when hydrogen bonding is important. The lower-wavenumber fingerprint region contains overlapping patterns valuable for distinguishing related compounds.\n\nA Fourier-transform infrared spectrometer typically uses a Michelson interferometer to encode spectral information into an interferogram recorded as optical path difference changes. A mathematical Fourier transform then recovers the spectrum. This approach permits accurate wavelength measurement and efficient acquisition over a broad interval. Its practical advantages depend on the source, detector, spectral resolution, and dominant noise sources; it is not automatically superior for every measurement.\n\nSampling methods adapt infrared analysis to gases, liquids, and solids. Transmission measurements pass radiation through a sample of controlled thickness. Gas cells may use multiple reflections to create long effective path lengths for trace constituents. Attenuated total reflection brings a sample into contact with a high-index crystal: an evanescent field extending beyond the reflecting interface interacts with the sample. This method allows many solids and liquids to be examined with little preparation, although penetration depth and spectral intensity depend on wavelength and optical geometry.\n\nQuantitative analysis often begins with the Beer–Lambert relation,\n\n\\[A=-\\log_{10}\\!\\left(\\frac{I}{I_0}\\right)=\\varepsilon c\\ell,\\]\n\nwhere \\(A\\) is absorbance, \\(I/I_0\\) is the transmitted fraction, \\(\\varepsilon\\) is molar absorptivity, \\(c\\) is concentration, and \\(\\ell\\) is path length. Deviations can arise from scattering, chemical interactions, instrumental bandwidth, or high concentration. Near-infrared analysis, whose overtone bands are often broad and overlapping, frequently uses multivariate statistical calibration against independently measured reference samples.\n\nApplications include identifying polymers, monitoring industrial gases, studying reaction progress, measuring food composition, and examining historical materials. Infrared and Raman spectroscopy provide complementary information because their selection rules differ. An infrared spectrum can support identification or compositional analysis, but complex mixtures and ambiguous bands often require additional analytical evidence."
    },
    {
      "heading": "Thermal imaging and remote sensing",
      "text": "Thermography forms images from infrared radiation and, in radiometric systems, estimates surface temperatures from measured radiance. This differs from ordinary near-infrared photography, which generally records reflected illumination. A short-wave camera may show patterns caused by material reflectance under sunlight, whereas a long-wave camera viewing an ordinary room primarily records thermal emission. At sufficiently high object temperatures, emitted radiation can become important even at short infrared wavelengths.\n\nA thermal camera does not directly read the internal temperature of an object. Its signal combines radiation emitted by the surface, radiation reflected from the surroundings, and atmospheric absorption and emission along the viewing path. Surface emissivity, distance, atmospheric conditions, and reflected apparent temperature therefore affect the inferred value. A shiny metal surface may show a thermal reflection of a nearby person or furnace rather than faithfully reveal its own temperature.\n\nImage colour is also a display choice. Most infrared cameras assign false colours or greyscale levels to measured signal values. Changing the palette or stretching the displayed range can greatly alter visual contrast without changing the underlying measurements. Cameras intended for quantitative work require radiometric calibration, often against characterized blackbody sources, and an account of measurement uncertainty. Thermal sensitivity, frequently expressed as noise-equivalent temperature difference, is distinct from absolute temperature accuracy.\n\nIndustrial thermography is used to locate abnormal heating in electrical equipment, inspect furnaces and insulation, and study heat flow through mechanical components. Building surveys reveal surface-temperature patterns associated with insulation defects, air leakage, or moisture-related processes. These patterns are not uniquely diagnostic: wind, sunlight, recent heating, surface finish, and viewing angle can produce similar appearances. Subsurface information is inferred from its influence on surface temperature rather than obtained by directly seeing through opaque material.\n\nAirborne and satellite infrared instruments extend these methods to large areas. Thermal bands support estimates of land- and sea-surface temperature, volcanic heat output, and fire activity. Short-wave infrared measurements help distinguish vegetation water content, burned areas, snow, and certain minerals. The Landsat programme, begun in 1972, has provided a long record of multispectral observations, with thermal imaging introduced on Landsat 3 in 1978 and developed in later missions.\n\nRetrieving physical quantities from satellite radiance requires atmospheric correction and knowledge of surface properties. Land-surface temperature and near-surface air temperature are different variables: vegetation, bare soil, buildings, and water can have contrasting surface temperatures under the same atmospheric conditions. Infrared observations therefore complement, rather than simply replace, measurements made by weather stations and other instruments."
    },
    {
      "heading": "Infrared astronomy",
      "text": "Astronomy uses infrared to observe cool objects, dust-obscured regions, molecular gas, and radiation shifted to longer wavelengths by cosmic expansion. Objects with temperatures from tens to thousands of kelvin emit substantial infrared radiation. Brown dwarfs, planets, circumstellar disks, and interstellar dust can consequently be much more conspicuous in infrared than in visible images. Different infrared bands reveal different physical components rather than merely providing a less obscured version of an optical scene.\n\nDust grains absorb and scatter visible light, hiding regions where stars form and obscuring parts of the Milky Way. Near-infrared observations often penetrate dusty regions more effectively because extinction is lower at longer wavelengths, though this trend has spectral features and is not universal. The absorbed stellar energy also heats dust, which reradiates strongly in the mid- and far-infrared. Far-infrared luminosity can therefore trace energy processed by dust, but interpreting it requires distinguishing heating by young stars, older stellar populations, and active galactic nuclei.\n\nGround-based infrared astronomy is limited by both atmospheric absorption and background emission. Telescopes are often placed at high, dry sites where water vapour is reduced. At thermal wavelengths, the atmosphere, telescope, and instrument all emit radiation that may greatly exceed the astronomical signal. Observing techniques such as rapid comparison between target and nearby sky help remove varying backgrounds. Cooling instruments and using low-emissivity optics reduce the background generated within the observatory.\n\nSpace observatories avoid atmospheric absorption and can access broad far-infrared regions unavailable from the ground. The 1983 Infrared Astronomical Satellite survey identified extensive populations of infrared-emitting stars and galaxies and revealed prominent dusty debris around stars such as Vega. Spitzer, operating from 2003 to 2020, studied topics including exoplanets, star formation, and distant galaxies. Herschel, whose observations ended in 2013 after its coolant was exhausted, extended observations into the far-infrared and submillimetre range.\n\nThe James Webb Space Telescope observes approximately 0.6–28.5 micrometres. Its sunshield and cold optical system suppress thermal emission, while its mid-infrared instrument uses additional cooling. Infrared sensitivity is especially important for studying early galaxies because cosmological redshift stretches their emitted ultraviolet and visible radiation into infrared wavelengths:\n\n\\[\\lambda_{\\mathrm{observed}}=(1+z)\\lambda_{\\mathrm{emitted}}.\\]\n\nInfrared spectroscopy reveals chemical composition, excitation conditions, and motion through molecular bands, atomic lines, and Doppler shifts. Observations of exoplanet transits and eclipses can constrain atmospheric constituents and thermal emission. Such interpretations depend on instrument calibration, stellar behaviour, clouds, and atmospheric models; a spectral feature is not automatically a unique indicator of a particular atmospheric composition or biological process."
    },
    {
      "heading": "Communications, sensing, and industrial uses",
      "text": "Near-infrared radiation carries much of the world’s long-distance optical telecommunications traffic. Optical fibre systems exploit wavelength regions where silica has low attenuation and favourable transmission properties. Two especially important regions lie near 1.3 and 1.55 micrometres. Standard single-mode silica fibre has low chromatic dispersion near 1.3 micrometres, while attenuation is particularly low near 1.55 micrometres, commonly approaching 0.2 decibels per kilometre in suitable telecommunications fibre.\n\nOptical transmitters modulate semiconductor lasers, and receivers convert the arriving radiation into electrical signals. Wavelength-division multiplexing sends several channels at different wavelengths through one fibre. Erbium-doped fibre amplifiers operate in important telecommunications bands near 1.55 micrometres, allowing optical signals to be amplified without first converting every channel into an electrical signal. Fibre communication uses guided radiation, so its performance is distinct from free-space transmission through air.\n\nShort-range free-space applications include remote controls, optical links between devices, and proximity sensors. Many consumer remote controls use near-infrared light-emitting diodes near 940 nanometres and transmit coded pulses, often on a carrier of a few tens of kilohertz. Receiver filtering and modulation help distinguish the intended signal from sunlight and indoor lighting. Solid obstacles usually block these links, although reflections from walls and ceilings may provide indirect paths.\n\nInfrared is also used in ranging and three-dimensional sensing. Lidar measures distance using transmitted optical pulses, phase shifts, or related timing techniques. Some systems operate near 905 nanometres, while others use wavelengths near 1,550 nanometres. Structured-light systems project an infrared pattern and infer depth from its observed deformation. Wavelength selection affects detector technology, atmospheric response, material reflectance, and eye-safety constraints; invisibility alone does not make an infrared beam safe.\n\nIndustrial heating uses absorbed infrared energy to raise the temperature of coatings, foods, plastics, textiles, and other products. Radiant heaters can transfer energy without requiring direct contact, but the depth and uniformity of heating depend on wavelength-dependent absorption and thermal transport within the material. A wavelength absorbed strongly at the surface may be useful for rapid drying yet unsuitable when uniform heating through a thick object is required.\n\nLaser machining applies concentrated infrared radiation to cutting, welding, drilling, and surface treatment. Carbon-dioxide lasers and near-infrared fibre lasers interact differently with metals, polymers, and other materials. Process performance depends on power density, pulse duration, absorptivity, and the evolving condition of the surface. In conservation science, infrared reflectography can reveal some underdrawings beneath paint layers when the paint becomes relatively transmissive and the underlying material provides sufficient infrared contrast."
    },
    {
      "heading": "Biological interactions and radiation safety",
      "text": "Biological effects of infrared depend on wavelength, irradiance, exposure duration, beam geometry, and tissue properties. Because individual infrared photons generally have insufficient energy to ionize ordinary biological molecules directly, infrared is classified as non-ionizing radiation. This classification does not imply harmlessness. Absorbed radiation can produce damaging temperature increases, and intense ultrashort pulses can generate nonlinear effects that are not described by simple bulk heating.\n\nWater is a major absorber in biological tissue, especially across much of the mid- and far-infrared. At strongly absorbed wavelengths, energy is deposited near the surface. Certain near-infrared intervals permit greater penetration because absorption by water and some other tissue constituents is lower, although scattering still redistributes the radiation. Penetration is not a fixed property of “infrared” as a whole: it varies markedly across the spectrum and among tissues.\n\nThe eye illustrates these differences. Near-infrared radiation within the retinal hazard region can pass through the front of the eye and be focused onto the retina. Because it is invisible, it does not produce the ordinary visual sensation associated with a bright visible source. At longer infrared wavelengths, absorption increasingly occurs in the cornea, aqueous humour, and lens rather than at the retina. Intense exposures can injure ocular tissues, while sustained occupational heat exposure has historically been associated with lens damage in industries involving hot furnaces or molten materials.\n\nSkin absorbs infrared through water and other constituents, producing warming and, at sufficiently high exposure, burns. Heat exchange with the surroundings also depends on air temperature, airflow, humidity, clothing, and physiological thermoregulation. Infrared radiation is therefore only one component of a person’s thermal environment. Thermal comfort cannot be inferred from air temperature alone, since nearby hot or cold surfaces alter radiant energy exchange.\n\nMedical and physiological instruments exploit more limited and controlled interactions. Pulse oximeters commonly compare absorption at a red wavelength and a near-infrared wavelength, often around 660 and 940 nanometres, to estimate arterial oxygen saturation from the pulsating signal. Near-infrared spectroscopy investigates changes associated with oxygenated and deoxygenated haemoglobin in tissue. These measurements depend on optical models, calibration, tissue scattering, and instrument-specific limitations rather than a direct visual reading of blood oxygen.\n\nInfrared thermography records surface-temperature patterns and does not directly image internal anatomy. Elevated skin temperature can have several causes, and a thermal image alone does not establish a specific diagnosis. Radiation-protection standards distinguish laser sources from broad-band lamps and specify exposure limits according to wavelength, duration, and the tissue at risk. Those distinctions reflect the underlying physics: a diffuse warm surface, a concentrated industrial beam, and a near-infrared communications source can occupy the same broad spectral region while presenting very different exposure conditions."
    }
  ],
  "links": [
    "electromagnetic-radiation",
    "light",
    "electromagnetic-spectrum",
    "speed-of-light",
    "photon",
    "planck-constant",
    "electronvolt",
    "reflection-optics",
    "refraction",
    "diffraction",
    "interference",
    "polarization",
    "royal-society",
    "blackbody-radiation",
    "max-planck",
    "quantum-mechanics",
    "world-war-ii",
    "heat",
    "temperature",
    "boltzmann-constant",
    "emissivity",
    "molecule",
    "phonon",
    "band-gap",
    "atmosphere-of-earth",
    "carbon-dioxide",
    "methane",
    "ozone",
    "pressure",
    "earth-energy-budget",
    "greenhouse-effect",
    "feedback",
    "radiative-transfer",
    "laser",
    "silicon",
    "calibration",
    "infrared-spectroscopy",
    "hydrogen-bond",
    "raman-spectroscopy",
    "measurement-uncertainty",
    "astronomy",
    "redshift",
    "optical-fiber",
    "lidar",
    "scattering",
    "thermoregulation",
    "hemoglobin",
    "diagnosis"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}