  "sections": [
    {
      "heading": "",
      "text": "A heat-recovery steam generator (HRSG) is a heat exchanger that transfers energy from a hot gas stream to water, producing steam. It is a type of boiler, most commonly installed downstream of a gas turbine to recover heat from its exhaust. The steam may drive a steam turbine, supply industrial processes, or serve both purposes. Unlike a conventional fired boiler, an unfired HRSG obtains its heat from an upstream process rather than from fuel burned within the boiler itself; some installations include supplementary burners."
    },
    {
      "heading": "Role in energy systems",
      "text": "In a combined-cycle power plant, the gas turbine generates electricity while discharging exhaust that still contains substantial thermal energy. The HRSG uses this exhaust to produce steam for a second power-producing cycle, usually a Rankine cycle. It connects the gas-turbine cycle to the steam cycle without mixing the exhaust gas with the water and steam.\n\nThis arrangement extracts more useful work from a fuel supply than a gas turbine operating alone. The additional electricity is generated largely from heat that would otherwise leave through the exhaust stack, although pumps, cooling equipment, and other auxiliaries consume some of the recovered output.\n\nIn combined heat and power installations, the steam can instead—or additionally—supply manufacturing processes or district heating. Its required pressure, temperature, and flow then depend on the heat users as well as on electricity production.\n\nThe term is especially associated with gas-turbine exhaust recovery. Equipment recovering heat from furnaces, engines, or chemical processes is also commonly described as a waste-heat boiler. These categories overlap rather than having a universally fixed boundary."
    },
    {
      "heading": "Main components and operation",
      "text": "An HRSG normally contains banks of tubes enclosed in an insulated gas duct or casing. Exhaust flows outside the tubes, while water and steam flow inside. Fins are often attached to the tubes to increase gas-side heat-transfer area.\n\nThe principal heating sections are:\n\n- Economizer: raises feedwater temperature before it enters the evaporating section.\n- Evaporator: supplies the heat needed to convert water into steam.\n- Superheater: raises steam temperature above its saturation temperature at the operating pressure.\n- Reheater: where fitted, reheats steam after it has expanded through the high-pressure section of a steam turbine.\n\nIn a simplified single-pressure arrangement, the hottest exhaust first encounters the superheater, then the evaporator, and finally the economizer before leaving through the stack. Water moves through the heating stages in the opposite functional sequence. Actual arrangements can be more complex: sections serving different pressure levels may be interleaved to improve heat recovery.\n\nIn a drum-type HRSG, a steam drum separates steam from the water–steam mixture leaving the evaporator. Water returns to the evaporator through downcomers, while separated steam passes to the superheater or directly to a user. Natural circulation relies on the density difference between the relatively cool water in the downcomers and the heated mixture in the evaporator circuits. Forced-circulation designs use pumps to drive this flow.\n\nA once-through HRSG has no recirculating steam drum in the steam-generating flow path. Feedwater passes through the heating surfaces and emerges as steam. Such systems require coordinated control of feedwater flow, heat input, and outlet conditions; particular designs may include startup separators or recirculation arrangements."
    },
    {
      "heading": "Thermodynamic performance",
      "text": "The heat transferred from an unfired exhaust stream can be approximated by an energy balance:\n\n\\[\\dot Q_{\\mathrm{recovered}} \\approx \\dot m_g c_{p,g} \\left(T_{g,\\mathrm{in}}-T_{g,\\mathrm{out}}\\right),\\]\n\nwhere \\(\\dot m_g\\) is exhaust-gas mass flow, \\(c_{p,g}\\) is its mean specific heat capacity, and \\(T_{g,\\mathrm{in}}\\) and \\(T_{g,\\mathrm{out}}\\) are inlet and outlet temperatures. This approximation neglects heat losses and treats specific heat as constant.\n\nOn the water–steam side, a simple single-stream balance is\n\n\\[\\dot Q_{\\mathrm{recovered}} \\approx \\dot m_s\\left(h_{\\mathrm{out}}-h_{\\mathrm{in}}\\right),\\]\n\nwhere \\(\\dot m_s\\) is the water or steam mass flow and \\(h\\) is specific enthalpy. Multiple-pressure systems, reheating circuits, blowdown, and supplementary firing require additional terms.\n\nPinch point and approach temperature\n\nTwo temperature differences are particularly important in drum-type HRSG design:\n\n- Evaporator pinch-point temperature difference: the exhaust-gas temperature leaving an evaporator minus the saturation temperature of the water in that pressure circuit.\n- Economizer approach temperature difference: the saturation temperature at drum pressure minus the water temperature leaving the economizer.\n\nA smaller pinch-point difference generally allows greater heat recovery but requires more heating surface and increases cost. A smaller approach difference brings feedwater closer to boiling, but insufficient margin can permit unwanted steaming in an economizer intended for liquid-water service, especially away from its design condition.\n\nMultiple pressure levels\n\nA single-pressure steam circuit cannot closely match the continuously declining temperature of the exhaust throughout the HRSG. Two- and three-pressure arrangements recover heat at different temperature levels, reducing temperature mismatches and improving the thermodynamic use of the available exhaust energy.\n\nLarge combined-cycle plants commonly use three pressure levels and steam reheating. Smaller plants or installations with a specific process-steam requirement may favor simpler arrangements. The most suitable configuration depends on exhaust conditions, required steam conditions, operating pattern, and capital cost."
    },
    {
      "heading": "Principal design configurations",
      "text": "Horizontal and vertical gas flow\n\nIn a horizontal-gas-flow HRSG, exhaust travels horizontally through banks that commonly contain vertical tubes. This arrangement is widely used with natural-circulation drum systems.\n\nIn a vertical-gas-flow HRSG, exhaust rises through banks that commonly contain horizontal tubes. Such units can reduce ground-area requirements but require a taller structure. Gas-flow orientation alone does not determine the circulation method: tube geometry, pressure, hydraulic resistance, and the overall design also matter.\n\nUnfired and supplementary-fired units\n\nAn unfired HRSG uses only the heat arriving with the exhaust.\n\nA supplementary-fired HRSG includes duct burners that burn additional fuel, often natural gas, in the exhaust stream. Gas-turbine exhaust normally retains sufficient oxygen to support additional combustion. Firing increases steam production and can help meet process demand independently of changes in gas-turbine load.\n\nSupplementary firing changes fuel consumption, emissions, metal temperatures, and the required capacity of heating surfaces. It does not necessarily increase overall electrical efficiency; its value depends on the plant arrangement and the usefulness of the additional steam or electricity."
    },
    {
      "heading": "Operation, control, and reliability",
      "text": "An HRSG must accommodate variations in exhaust flow and temperature, steam demand, and steam-turbine operating conditions. Process control systems regulate feedwater, drum level, steam temperature, pressure, and supplementary firing where installed. Water-spray attemperators are often used to control superheated or reheated steam temperature.\n\nStartup and shutdown are particularly demanding. Thick-walled drums and headers heat and cool more slowly than thin tubes. Uneven expansion creates thermal stresses, so startup procedures must respect temperature differences and component heating rates. Repeated cycling can cause fatigue, while long exposure to high temperatures can produce creep damage.\n\nImportant operating and degradation issues include:\n\n- Water and steam chemistry: deposits impede heat transfer, while unsuitable chemistry can promote corrosion or contaminate downstream turbine equipment.\n- Flow-accelerated corrosion: dissolution of protective oxide films can thin susceptible steel components under particular water-chemistry and flow conditions.\n- Drum swell and shrink: changes in pressure and steam-bubble volume can move the indicated drum level independently of changes in water inventory.\n- Condensate management: accumulated water in superheater and reheater sections can cause severe temperature differences when hot gas or steam arrives.\n- Tube and header fatigue: repeated differential expansion can damage connections and other stress-concentrating features.\n- Gas-side fouling: deposits reduce heat transfer and increase exhaust pressure loss.\n\nInspection may include thickness measurements and other forms of nondestructive testing. Pressure-relief devices and protective interlocks are essential elements of process safety."
    },
    {
      "heading": "Environmental and design constraints",
      "text": "Heat recovery can reduce fuel consumption and associated emissions per unit of useful output compared with an otherwise similar system that discards the exhaust heat. Nevertheless, an HRSG does not make fossil-fuel combustion emission-free, and supplementary firing adds emissions of its own.\n\nHRSGs may house selective catalytic reduction equipment for nitrogen-oxide control and oxidation catalysts for carbon monoxide control. Catalyst placement depends partly on the required gas-temperature range.\n\nHeat recovery is also limited by practical constraints:\n\n- Exhaust backpressure: tube banks, catalysts, and ductwork resist gas flow. Excessive pressure loss reduces gas-turbine performance.\n- Minimum stack temperature: excessive cooling can cause condensation and corrosion, particularly when sulfur-containing fuels produce acidic condensates. Ordinary non-condensing designs therefore retain a temperature margin.\n- Equipment size and cost: recovering progressively more heat generally requires additional surface area, larger structures, or more pressure circuits.\n- Steam-cycle heat rejection: when recovered heat produces electricity, much of it must still be rejected through a condenser and cooling system.\n- Operating flexibility: a design optimized for steady full-load operation may face greater thermal stress or reduced efficiency during frequent starts and part-load service."
    },
    {
      "heading": "Development and applications",
      "text": "Heat-recovery boilers developed from the broader practice of using hot industrial exhaust to raise steam. Their importance increased as gas turbines became widely used for electricity generation and combined-cycle plants became established. Designs evolved toward higher steam conditions, multiple pressure circuits, reheating, and improved arrangements for cycling operation.\n\nBeyond utility power generation, HRSGs serve industrial cogeneration plants, refineries, chemical facilities, and other sites with substantial steam demand. Selection is governed not simply by the amount of recoverable heat, but by its temperature, the required steam conditions, the variability of the upstream process, and the availability of a dependable steam user."
    }
  ],
  "links": [
    "heat-exchanger",
    "boiler",
    "gas-turbine",
    "steam-turbine",
    "combined-cycle-power-plant",
    "combined-heat-and-power",
    "district-heating",
    "energy-balance",
    "thermodynamics",
    "natural-gas",
    "process-control",
    "creep",
    "process-safety",
    "condenser-heat-exchanger"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}