  "id": "flux-linkage",
  "title": "Flux Linkage",
  "lang": "en",
  "source_lang": "en",
  "summary": "Flux linkage is the sum of the magnetic fluxes linked by the turns of a winding, governing its induced voltage and inductive behavior.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Magnetic flux linkage"
  ],
  "generated_at": "2026-11-06",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/flux-linkage/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/flux-linkage/",
      "json": "https://aiwiki.page/zh/flux-linkage.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "Flux linkage is the total magnetic flux linked by the turns of an electrical winding, with each turn counted according to its orientation. Usually denoted by \\(\\lambda\\) or \\(\\Psi\\), it connects the spatial description of a magnetic field to the voltage and current behavior of a circuit. For a coil of \\(N\\) turns that all link the same flux \\(\\Phi\\), the flux linkage is \\(\\lambda=N\\Phi\\). More generally, it is the algebraic sum of the fluxes linked by the individual turns."
    },
    {
      "heading": "Definition and units",
      "text": "For a winding represented as \\(N\\) series-connected turns,\n\n\\[\\lambda=\\sum_{k=1}^{N}\\Phi_k, \\qquad \\Phi_k=\\int_{S_k}\\mathbf{B}\\cdot d\\mathbf{S},\\]\n\nwhere \\(\\mathbf{B}\\) is magnetic flux density and \\(S_k\\) is a surface bounded by the \\(k\\)th turn. Each surface orientation must be consistent with the chosen winding direction. Turns connected in opposition therefore contribute with opposite signs.\n\nThe flux through a turn does not depend on the particular spanning surface chosen, provided the surfaces share the same boundary. This follows from the absence of magnetic monopoles in classical Maxwell’s equations, expressed by \\(\\nabla\\cdot\\mathbf{B}=0\\).\n\nIn the International System of Units, flux linkage has the unit weber, equivalent to volt-second. The engineering notation weber-turn is often used to emphasize the summation over turns, but the turn is dimensionless and does not introduce a separate physical dimension.\n\nMagnetic flux and flux linkage are related but distinct:\n\n- Magnetic flux describes the field passing through a specified surface.\n- Flux linkage describes how that flux couples to an entire winding.\n\nConsequently, two windings exposed to the same flux per turn can have different flux linkages if their numbers of turns differ."
    },
    {
      "heading": "Relation to electromagnetic induction",
      "text": "The main significance of flux linkage follows from Faraday’s law of induction. For an oriented winding, the induced electromotive force is\n\n\\[\\mathcal{E}=-\\frac{d\\lambda}{dt}.\\]\n\nThe negative sign expresses Lenz’s law: the induced effect opposes the change producing it. Flux linkage can change because the field changes, because the winding moves or deforms, or because both occur. For moving circuits, the derivative includes the changing geometry of the turns; the underlying force on charges includes the magnetic part of the Lorentz force.\n\nIn circuit analysis, a different-looking sign commonly appears because voltage is defined as a terminal drop rather than as an induced electromotive force around the winding. Under the passive sign convention, a lumped winding with resistance \\(R\\) satisfies\n\n\\[v=Ri+\\frac{d\\lambda}{dt},\\]\n\nwhere current \\(i\\) enters the terminal assigned positive voltage. This relation assumes that distributed effects, such as interturn capacitance and wave propagation, can be neglected.\n\nA constant flux linkage produces no induced voltage. Thus, a stationary winding may link a strong permanent magnetic field while having zero induced electromotive force."
    },
    {
      "heading": "Self-inductance and mutual coupling",
      "text": "Linear windings\n\nFor a fixed winding in a linear magnetic system, with no independently imposed magnetic field,\n\n\\[\\lambda=Li,\\]\n\nwhere \\(L\\) is its self-inductance and \\(i\\) is the current. If \\(L\\) is constant,\n\n\\[v=Ri+L\\frac{di}{dt}.\\]\n\nIf geometry changes so that \\(L\\) varies with time, the inductive voltage instead includes both terms:\n\n\\[\\frac{d\\lambda}{dt} = L\\frac{di}{dt} +i\\frac{dL}{dt}.\\]\n\nFor an ideal long solenoid of length \\(\\ell\\), cross-sectional area \\(A\\), and uniform linear magnetic permeability \\(\\mu\\),\n\n\\[\\lambda\\approx\\frac{\\mu N^2A}{\\ell}i, \\qquad L\\approx\\frac{\\mu N^2A}{\\ell}.\\]\n\nThe approximate \\(N^2\\) dependence arises because increasing the turn count both strengthens the field produced by a given current and increases the number of turns linking that field.\n\nCoupled windings\n\nFor several fixed windings in a linear system,\n\n\\[\\lambda_j=\\sum_k L_{jk}i_k+\\lambda_{j,\\mathrm{ext}},\\]\n\nwhere \\(L_{jj}\\) is a self-inductance, \\(L_{jk}\\) for \\(j\\ne k\\) is a mutual inductance, and \\(\\lambda_{j,\\mathrm{ext}}\\) represents linkage from independently imposed fields. The signs of the mutual terms depend on the winding orientations and reference directions.\n\nNot all flux produced by one winding links another. Flux that does not contribute to their common coupling is described as leakage flux. It still contributes to the flux linkage of the winding that it links."
    },
    {
      "heading": "Nonlinearity and magnetic history",
      "text": "In cores made from ferromagnetic materials, flux linkage need not be proportional to current. As magnetic saturation develops, further increases in current generally produce progressively smaller increases in linkage.\n\nFor a single-valued relationship \\(\\lambda(i)\\), two inductance measures can be distinguished:\n\n\\[L_{\\mathrm{sec}}=\\frac{\\lambda}{i}, \\qquad L_{\\mathrm{diff}}=\\frac{d\\lambda}{di}.\\]\n\nThe secant inductance describes the ratio at an operating point, while differential inductance describes the local response to a small current change. These definitions require care when a permanent magnet or remanent magnetization contributes an offset to the linkage.\n\nMagnetic hysteresis makes flux linkage depend on the previous magnetic state as well as the present current. Eddy currents and frequency-dependent material behavior introduce additional dependence on time and operating conditions. A single constant \\(L\\) cannot fully represent such behavior."
    },
    {
      "heading": "Energy and electromechanical conversion",
      "text": "For a lossless magnetic system at fixed geometry, the incremental energy supplied to the magnetic field is\n\n\\[dW_{\\mathrm{m}}=i\\,d\\lambda.\\]\n\nFor a reversible system referenced to an unenergized state,\n\n\\[W_{\\mathrm{m}}=\\int_0^\\lambda i(\\lambda')\\,d\\lambda'.\\]\n\nIn the linear case, this reduces to\n\n\\[W_{\\mathrm{m}} =\\frac{1}{2}Li^2 =\\frac{\\lambda^2}{2L}.\\]\n\nMagnetic coenergy is a related quantity,\n\n\\[W_{\\mathrm{m}}'=\\int_0^i\\lambda(i')\\,di'.\\]\n\nEnergy and coenergy are equal for a linear system with no magnetic offset, but generally differ in nonlinear systems.\n\nWhen linkage also depends on mechanical position, these quantities connect circuit behavior to force and torque. For a lossless, singly excited system with angular coordinate \\(\\theta\\),\n\n\\[\\tau= \\left(\\frac{\\partial W_{\\mathrm{m}}'}{\\partial\\theta}\\right)_i.\\]\n\nFlux-linkage models are therefore useful for describing both induced voltage and electromechanical conversion."
    },
    {
      "heading": "Applications and measurement",
      "text": "In a transformer, a changing common core flux links two or more windings. If each winding links the same flux per turn and leakage is negligible,\n\n\\[\\lambda_1=N_1\\Phi, \\qquad \\lambda_2=N_2\\Phi.\\]\n\nThe corresponding induced voltages have magnitudes in the ratio \\(N_1:N_2\\).\n\nIn an electric motor or generator, linkage can depend on both winding current and rotor position. For a simplified model \\(\\lambda(i,\\theta)\\),\n\n\\[\\frac{d\\lambda}{dt} = \\frac{\\partial\\lambda}{\\partial i}\\frac{di}{dt} + \\frac{\\partial\\lambda}{\\partial\\theta}\\frac{d\\theta}{dt}.\\]\n\nThe second term describes a speed-dependent contribution to the induced voltage.\n\nFlux-linkage changes can be determined experimentally by integrating the inductive component of terminal voltage:\n\n\\[\\lambda(t)-\\lambda(t_0) = \\int_{t_0}^{t}\\bigl[v(\\tau)-Ri(\\tau)\\bigr]\\,d\\tau.\\]\n\nThis determines a change in linkage, not its absolute initial value. Voltage offsets, uncertain resistance, and integration drift are important sources of measurement uncertainty.\n\nFor example, a 200-turn coil whose turns each link \\(0.50\\,\\mathrm{mWb}\\) has a linkage of \\(0.10\\,\\mathrm{Wb}\\). If that linkage falls uniformly to zero in \\(0.020\\,\\mathrm{s}\\), the magnitude of its average induced electromotive force is \\(5.0\\,\\mathrm{V}\\)."
    },
    {
      "heading": "Modeling limitations",
      "text": "The approximation \\(\\lambda=N\\Phi\\) is valid only when all turns link the same flux. Fringing fields, leakage, and spatially varying fields may require separate turn-by-turn calculations or numerical field analysis.\n\nAt high frequencies, distributed capacitance, skin effect, and nonuniform current distribution can make a single lumped flux-linkage variable inadequate. Detailed models may divide a winding into coupled sections or solve the electromagnetic field directly. Flux linkage remains useful in these cases, but its assignment to a particular circuit element must be consistent with the chosen model."
    }
  ],
  "links": [
    "magnetic-flux",
    "magnetic-field",
    "maxwells-equations",
    "international-system-of-units",
    "faraday-law-of-induction",
    "lorentz-force",
    "electrical-resistance",
    "inductance",
    "electric-current",
    "permeability",
    "ferromagnetism",
    "magnetization",
    "energy",
    "force",
    "torque",
    "transformer-architecture",
    "electric-motor",
    "measurement-uncertainty"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}