  "sections": [
    {
      "heading": "",
      "text": "An energy balance is a quantitative statement of the conservation of energy for a specified system. It relates changes in stored energy to energy transferred across the system boundary by heat, work, and matter. In engineering, it is used to calculate quantities such as heating requirements, power output, fuel consumption, operating temperatures, and energy-storage capacity. Together with a mass balance, it forms a basic framework for analyzing industrial processes, machines, buildings, and environmental systems.\n\nThe governing principle is the first law of thermodynamics: energy is conserved even when it changes form. A turbine converts part of a fluid stream’s energy into shaft work; a heater transfers energy into a material; a reacting mixture converts chemical energy into thermal and other forms. An energy balance accounts for these transformations without, by itself, determining their direction, speed, or practical efficiency.\n\nThe same conservation principle applies from individual equipment items to entire industrial sites. Its mathematical form depends on the chosen boundary, whether matter crosses that boundary, whether conditions change with time, and which energy forms matter at the scale of analysis. Reliable use therefore requires more than writing an equation: it requires consistent property data, explicit sign conventions, defensible assumptions, and an understanding of what the measurements actually represent."
    },
    {
      "heading": "Physical foundations and system boundaries",
      "text": "Energy balances developed from the nineteenth-century establishment of the mechanical equivalence of heat. Julius Robert Mayer argued for the equivalence of mechanical and thermal effects in 1842; James Prescott Joule’s experiments during the 1840s quantified the conversion of mechanical work into heat; and Hermann von Helmholtz presented a broad conservation principle in 1847. Rudolf Clausius subsequently helped formulate the mathematical foundations of thermodynamics. These developments replaced the treatment of heat as a conserved material substance with a theory in which heat and work are modes of energy transfer.\n\nThe first step in an energy balance is defining the system. A closed system, also called a control mass, contains a fixed quantity of matter: matter does not cross its boundary, although heat and work may do so. Gas trapped behind a sealed piston is a standard example. An open system is commonly analyzed using a control volume, a region through which matter may flow. A turbine, pump, boiler, and section of pipe are usually modeled this way. An isolated system exchanges neither matter nor energy with its surroundings.\n\nThe boundary may be physical, such as the wall of a tank, or imaginary, such as a plane cutting across a flowing pipe. Its placement determines which transfers appear in the balance. For a boundary enclosing only an electric motor, electrical work enters and shaft work leaves, together with heat rejected to the surroundings. If the boundary also encloses the driven pump, the shaft transfer between motor and pump becomes internal and disappears from the overall balance. Internal transfers cancel when component balances are combined.\n\nStored energy is commonly separated into internal energy, macroscopic kinetic energy, and gravitational potential energy:\n\n\\[E=U+\\frac{1}{2}mV^2+mgz.\\]\n\nHere \\(U\\) includes microscopic contributions associated with molecular motion, intermolecular interactions, and chemical composition. The speed \\(V\\) describes bulk motion, while \\(z\\) is elevation relative to a chosen datum. A spatially extended system may require integrating kinetic and potential energy over its mass rather than using a single representative velocity or elevation.\n\nHeat is energy transferred because of a temperature difference; work comprises other organized energy transfers across a boundary, including shaft rotation, electrical transfer, and boundary displacement. Neither heat nor work is a substance contained in a body. A hot tank contains internal energy, not “heat content” in the strict thermodynamic sense.\n\nBoundary conditions also require careful terminology. An adiabatic boundary permits no heat transfer, but may permit work and mass transfer. An isothermal process maintains constant temperature, but may require substantial heat transfer. A steady system has no time-dependent accumulation within the selected control volume; it need not have uniform temperature, pressure, or composition throughout. Confusing these distinctions can remove terms that are essential to the actual process."
    },
    {
      "heading": "General equations for closed and flowing systems",
      "text": "For a closed system, one common sign convention takes heat added to the system as positive and work done by the system as positive. The first law then becomes\n\n\\[\\Delta E=Q-W,\\]\n\nor, in rate form,\n\n\\[\\frac{dE}{dt}=\\dot Q-\\dot W.\\]\n\nA dot denotes a rate, so \\(\\dot Q\\) and \\(\\dot W\\) have units of power. Under the International System of Units, energy is measured in joules and power in watts, with \\(1\\ \\mathrm{W}=1\\ \\mathrm{J\\,s^{-1}}\\). Some engineering conventions instead define work into the system as positive; either convention is valid if used consistently.\n\nFor a gas expanding against a resisting external pressure, moving-boundary work is\n\n\\[W_b=\\int_{V_1}^{V_2}p_{\\mathrm{ext}}\\,dV.\\]\n\nThe external pressure is important: substituting the gas pressure is justified only under suitable mechanical-equilibrium assumptions. Closed-system work may also include stirring, electrical input, or deformation. A rigid vessel has no volume-change work, but an electrical heater inside it can still transfer energy into its contents through the electrical connections crossing the boundary.\n\nFor a fixed control volume with discrete inlet and outlet streams, the usual engineering balance is\n\n\\[\\frac{dE_{\\mathrm{cv}}}{dt} = \\dot Q-\\dot W_s + \\sum_{\\mathrm{in}}\\dot m \\left(h+\\frac{V^2}{2}+gz\\right) - \\sum_{\\mathrm{out}}\\dot m \\left(h+\\frac{V^2}{2}+gz\\right).\\]\n\nHere \\(\\dot m\\) is mass flow rate, \\(h\\) is specific enthalpy, and \\(\\dot W_s\\) represents work output other than the flow work already included in enthalpy. Depending on the equipment, this work may be shaft work, electrical work, or another explicitly identified transfer.\n\nEnthalpy is defined by\n\n\\[h=u+pv,\\]\n\nwhere \\(u\\) is specific internal energy and \\(v\\) is specific volume. The \\(pv\\) term incorporates the pressure work associated with moving matter through the control surface. Adding a separate \\(p\\dot V\\) flow-work term to a balance that already uses inlet and outlet enthalpies would generally double-count that contribution.\n\nAt steady state, \\(dE_{\\mathrm{cv}}/dt=0\\). For one inlet and one outlet with equal mass flow rates, division by \\(\\dot m\\) gives\n\n\\[q-w_s = h_2-h_1 +\\frac{V_2^2-V_1^2}{2} +g(z_2-z_1),\\]\n\nwhere \\(q=\\dot Q/\\dot m\\) and \\(w_s=\\dot W_s/\\dot m\\). This compact equation underlies many equipment calculations, but the omitted or retained terms must follow from the physical circumstances rather than from the equation’s familiarity.\n\nEnergy conservation does not imply that thermal energy alone is conserved. Friction can reduce mechanical energy while increasing internal energy; a chemical reaction can change temperature without an external heat input. Likewise, a steady balance does not mean that energy flows vanish: a power station can sustain enormous energy throughputs while its stored energy remains approximately constant. The equation describes the accounting of all relevant forms, not merely the persistence of any one form."
    },
    {
      "heading": "Thermophysical properties and reference states",
      "text": "An energy balance usually becomes solvable only after stored energies and stream enthalpies have been related to measurable conditions. These relationships depend on temperature, pressure, composition, and phase. Property tables, experimentally fitted correlations, and an equation of state supply the necessary information. Choosing an inappropriate property model can introduce a larger error than neglecting a small heat leak or elevation change.\n\nFor a fixed-composition ideal gas, internal energy and enthalpy depend only on temperature:\n\n\\[u_2-u_1=\\int_{T_1}^{T_2}c_v(T)\\,dT, \\qquad h_2-h_1=\\int_{T_1}^{T_2}c_p(T)\\,dT.\\]\n\nThe quantities \\(c_v\\) and \\(c_p\\) are specific heat capacities. If their variation is small over the temperature interval, constant average values may be used. The familiar expression \\(Q=mc_p\\Delta T\\) is therefore not a universal statement of the first law. It is a result applicable to particular process conditions, such as sensible heating at approximately constant pressure with negligible additional energy effects.\n\nFor a nearly incompressible liquid, changes in internal energy are often approximated from temperature alone. Enthalpy can nevertheless retain a pressure contribution:\n\n\\[\\Delta h\\approx c_p\\Delta T+v\\Delta p.\\]\n\nAt ordinary heating conditions the pressure term may be small, whereas in a high-pressure pump it is central. For real gases near condensation or near the critical region, ideal-gas expressions can be seriously inaccurate. Steam-power calculations consequently use water-and-steam property formulations or tables rather than a single constant heat capacity.\n\nPhase transitions require a different treatment from sensible heating. During equilibrium boiling of a pure substance at fixed pressure, energy can be added without changing temperature. The corresponding enthalpy difference is commonly described as latent heat. For a saturated liquid–vapor mixture,\n\n\\[h=(1-x)h_f+xh_g,\\]\n\nwhere \\(x\\) is vapor mass fraction, and \\(h_f\\) and \\(h_g\\) are saturated-liquid and saturated-vapor enthalpies. Near atmospheric pressure, vaporizing water requires roughly \\(2.26\\ \\mathrm{MJ\\,kg^{-1}}\\), much more than the approximately \\(0.33\\ \\mathrm{MJ\\,kg^{-1}}\\) needed to warm liquid water from \\(20^\\circ\\mathrm{C}\\) to \\(100^\\circ\\mathrm{C}\\). This difference explains the large duties of evaporators and steam condensers.\n\nAbsolute numerical values of internal energy and enthalpy depend on reference conventions. Nonreacting balances ordinarily require only differences, so an arbitrary common reference cancels. Problems arise when streams are evaluated using incompatible property packages or different reference states without correction.\n\nMixtures introduce additional effects. The enthalpy of mixing need not vanish, especially for strongly interacting liquids. Dissolving a substance, diluting an acid, or absorbing a gas can release or absorb appreciable energy even without a chemical reaction in the simplified process description. In separation equipment, composition changes and phase equilibrium must therefore be incorporated alongside temperature changes. Treating every stream as an ideal mixture with a constant heat capacity can conceal precisely the energy effects that control the operation."
    },
    {
      "heading": "Steady-flow equipment and thermal networks",
      "text": "Many engineering devices operate sufficiently close to steady conditions that accumulation can be neglected over the interval of interest. The resulting balances are especially useful in chemical engineering, power generation, and refrigeration. They relate equipment duties directly to stream properties, while performance models determine how closely real devices approach ideal behavior.\n\nFor an approximately adiabatic turbine with negligible changes in velocity and elevation,\n\n\\[\\dot W_{\\mathrm{out}}=\\dot m(h_1-h_2).\\]\n\nA steam turbine producing a specific enthalpy decrease of \\(800\\ \\mathrm{kJ\\,kg^{-1}}\\) at a flow rate of \\(10\\ \\mathrm{kg\\,s^{-1}}\\) would deliver \\(8\\ \\mathrm{MW}\\) of shaft power under these assumptions. A compressor reverses the energy-transfer direction: shaft work raises the gas enthalpy. For an approximately adiabatic liquid pump, the required specific work is often estimated as \\(v\\Delta p/\\eta_p\\), where \\(\\eta_p\\) is pump efficiency.\n\nIn a heat exchanger, energy leaving a hot stream enters a colder stream, apart from losses to the surroundings. For an externally insulated exchanger with no work transfer,\n\n\\[\\dot m_h(h_{h,\\mathrm{in}}-h_{h,\\mathrm{out}}) = \\dot m_c(h_{c,\\mathrm{out}}-h_{c,\\mathrm{in}}).\\]\n\nHeating water at \\(2\\ \\mathrm{kg\\,s^{-1}}\\) from \\(20^\\circ\\mathrm{C}\\) to \\(60^\\circ\\mathrm{C}\\), using an average heat capacity of \\(4.18\\ \\mathrm{kJ\\,kg^{-1}\\,K^{-1}}\\), requires about \\(334\\ \\mathrm{kW}\\). This determines the duty, not the exchanger’s required surface area. Area sizing additionally needs heat-transfer coefficients, temperature differences, flow arrangement, and allowance for fouling.\n\nA throttling valve illustrates why a pressure drop does not necessarily indicate work output. If the valve is adiabatic, produces no shaft work, and has negligible kinetic and potential energy changes between its inlet and outlet stations, then\n\n\\[h_1\\approx h_2.\\]\n\nThe process is approximately isenthalpic. Temperature may rise or fall depending on the fluid and inlet state. In a nozzle, by contrast, an enthalpy decrease largely appears as increased kinetic energy. Treating a nozzle as a throttling valve would therefore discard its principal function.\n\nFor a complete Rankine cycle or refrigeration loop, balances around individual components can be added to obtain a cycle balance. Working-fluid enthalpy transfers between adjacent devices cancel, leaving external heat and work interactions. In a heat pump, the heat delivered to the warm space equals heat extracted from the cold source plus work input. Delivered heat can consequently exceed electrical input without violating conservation.\n\nIndustrial sites extend this reasoning to steam headers, condensate returns, cooling-water circuits, and district heating. The selected boundary determines whether recovered heat is an internal exchange or a useful external output. Heat recovery reduces purchased energy only when its temperature, timing, and availability match an actual demand. A balance establishes the available quantity; thermal-network design establishes whether that quantity can be transferred usefully."
    },
    {
      "heading": "Chemical reactions, combustion, and electrochemical systems",
      "text": "Reacting systems require explicit accounting for changes in chemical composition. A balance based only on inlet and outlet temperatures is insufficient because substances at the same temperature can have very different chemical energies. The standard approach assigns each species an enthalpy of formation and then adds sensible and phase-change contributions relative to a consistent reference condition.\n\nFor a reaction written with stoichiometric coefficients \\(\\nu_i\\), positive for products and negative for reactants, the standard reaction enthalpy is\n\n\\[\\Delta_r H^\\circ = \\sum_i \\nu_i\\Delta_f H_i^\\circ.\\]\n\nThis follows from Hess’s law: enthalpy is a state function, so the overall change depends on initial and final states, not the reaction pathway. Standard thermochemical data are commonly tabulated at \\(298.15\\ \\mathrm{K}\\) and a standard pressure of \\(1\\ \\mathrm{bar}\\). Corrections are needed when streams enter or leave at other temperatures or in other phases.\n\nTwo bookkeeping methods are widely used. One includes formation enthalpies directly in every stream enthalpy. The other separates sensible enthalpy changes from an explicit reaction-enthalpy term. Both are valid when applied consistently, but including full formation enthalpies and then adding the same reaction heat separately counts chemical energy twice. Although process descriptions often speak of “heat generation,” chemical energy is being converted into other forms rather than created.\n\nCombustion calculations illustrate the practical consequences. The higher heating value of a fuel includes the energy recovered when product water condenses to liquid; the lower heating value leaves that water as vapor. For methane, representative values are approximately \\(55.5\\) and \\(50.0\\ \\mathrm{MJ\\,kg^{-1}}\\), respectively. An efficiency quoted without stating the heating-value basis can therefore be misleading. Some condensing-boiler efficiencies exceed 100 percent on a lower-heating-value basis because that denominator excludes recoverable condensation energy.\n\nAn adiabatic flame-temperature calculation sets external heat transfer to zero and equates reactant and product enthalpies. The released chemical energy raises product temperature, but high-temperature dissociation limits that rise. Excess air introduces additional nitrogen and oxygen that absorb energy, generally reducing flame temperature. Accurate calculations may require simultaneous chemical-equilibrium and energy-balance solutions rather than complete-combustion stoichiometry alone.\n\nIn reactors such as those used in the Haber process, heat release affects both temperature and reaction equilibrium. Energy balances must therefore be coupled to reaction rates, conversion, pressure, and heat removal. Similar reasoning applies to fermentation, where metabolic heat can become an important cooling load despite relatively modest operating temperatures.\n\nA fuel cell partitions the energy change of an electrochemical reaction between electrical output and heat transfer. The reversible electrical-work limit is associated with Gibbs free energy, not the entire reaction enthalpy. In a battery, thermal behavior can include resistive heating, reversible entropic effects, and side reactions. An electrical input–output balance alone does not fully describe its internal heat generation or changing chemical-energy inventory."
    },
    {
      "heading": "Transient storage and dynamic behavior",
      "text": "A transient energy balance retains accumulation because temperatures, phase fractions, compositions, or inventories change with time. Such balances describe startup, shutdown, charging, discharging, batch processing, and disturbances. They are also essential when nominally steady equipment is observed over intervals short enough for its stored energy to matter.\n\nFor a well-mixed tank containing a fixed mass of liquid with approximately constant heat capacity, a simple model is\n\n\\[mc_p\\frac{dT}{dt} = \\dot Q_{\\mathrm{heater}}-UA(T-T_a).\\]\n\nHere \\(UA\\) is the overall thermal conductance between tank and surroundings, and \\(T_a\\) is ambient temperature. The model assumes that the liquid has a nearly uniform temperature and that the tank wall’s heat capacity is either negligible or included in an effective thermal capacitance. With no heating and constant ambient temperature, the solution is\n\n\\[T(t)-T_a = [T(0)-T_a]\\exp\\left(-\\frac{t}{\\tau}\\right), \\qquad \\tau=\\frac{mc_p}{UA}.\\]\n\nThe time constant \\(\\tau\\) characterizes the response: after one time constant, the initial temperature difference has fallen to about 36.8 percent of its original value.\n\nA flowing, well-mixed tank adds enthalpy transport. Under constant-mass and constant-property assumptions,\n\n\\[mc_p\\frac{dT}{dt} = \\dot m c_p(T_{\\mathrm{in}}-T) +\\dot Q_{\\mathrm{heater}} -UA(T-T_a).\\]\n\nIf the tank level changes, the mass balance must be solved alongside the energy balance. Writing \\(mc_p\\,dT/dt\\) without examining the changing inventory can omit part of the stored-energy derivative or misrepresent inlet and outlet effects.\n\nGas-vessel filling provides a less intuitive example. For an initially evacuated, rigid, adiabatic tank filled from a source of constant specific enthalpy, the stored internal energy after filling equals the entering enthalpy carried by the accumulated mass, assuming other energy terms are negligible. The entering stream brings flow work as part of its enthalpy. Consequently, the final gas temperature need not equal the source temperature. This behavior cannot be captured by treating the process as simple mixing of equal-temperature material.\n\nEnergy storage systems use different state variables. Sensible thermal storage depends mainly on temperature; latent storage using a phase-change material depends strongly on the amount transformed; pumped storage depends on water inventory and elevation. Stratified hot-water tanks require multiple layers or spatially resolved models because a single mean temperature can conceal the temperature available at the outlet.\n\nDynamic balances underpin process control. Heater input, coolant flow, or feed rate acts on a system whose energy inventory introduces delays and time constants. A PID controller may regulate measured temperature, but the underlying response depends on thermal capacitance, transport delays, and heat-transfer characteristics. In exothermic reactors, coupling between temperature-sensitive reaction rates and heat removal can produce multiple steady states or thermal runaway. The conservation equation remains valid throughout; the difficulty lies in the nonlinear mechanisms determining its terms."
    },
    {
      "heading": "Spatial transport and multiphysics models",
      "text": "A single overall balance determines net transfers but cannot generally determine temperature distributions, wall hot spots, or local heat fluxes. Spatially resolved analysis divides the system into small regions and applies conservation locally. This connects energy balances to transport phenomena, fluid mechanics, and numerical simulation.\n\nFor a stationary solid with constant density \\(\\rho\\), heat capacity \\(c_p\\), and thermal conductivity \\(k\\), a common local equation is\n\n\\[\\rho c_p\\frac{\\partial T}{\\partial t} = \\nabla\\cdot(k\\nabla T)+\\dot q'''.\\]\n\nThe source \\(\\dot q'''\\) is energy converted into thermal energy per unit volume and time. If \\(k\\) is constant, the conduction term becomes \\(k\\nabla^2T\\). Electrical resistance heating, absorption of radiation, or chemical reactions may supply volumetric source terms. These are not exceptions to energy conservation: they describe conversions from energy forms tracked elsewhere in the coupled model.\n\nFor moving fluids, advection carries energy through space. A simplified constant-property temperature equation for an incompressible fluid is\n\n\\[\\rho c_p \\left( \\frac{\\partial T}{\\partial t} +\\mathbf{v}\\cdot\\nabla T \\right) = \\nabla\\cdot(k\\nabla T)+\\dot q'''.\\]\n\nThis form omits effects that can matter in other regimes, including compressibility and viscous dissipation. High-speed gas flows, strong pressure changes, and multicomponent reacting flows require more complete internal-energy, enthalpy, or total-energy equations. Species diffusion can also transport enthalpy.\n\nBoundary conditions close the spatial problem. A wall may have prescribed temperature, prescribed heat flux, or convective exchange with a surrounding fluid. Thermal radiation introduces a nonlinear temperature dependence, commonly involving \\(T^4\\), and may require accounting for surface emissivity and geometric view factors. At interfaces between materials, temperature and heat-flux conditions must reflect contact resistance or other interfacial physics.\n\nThe finite-volume method is particularly closely aligned with energy accounting. It integrates a conservation equation over each computational cell and calculates fluxes through the cell faces. When neighboring cells use a consistent shared face flux, internal transfers cancel in the assembled domain balance. This conservative structure does not guarantee accuracy, but it provides a strong check against artificial creation or loss of energy during discretization.\n\nMultiphysics applications require special attention to transfers between models. In an electric motor, electrical losses become heat while electromagnetic forces produce mechanical output. In a solar cell, absorbed radiation is divided among electrical output, thermal effects, and other optical or electronic pathways. In a nuclear reactor, energy from nuclear transformations is deposited through radiation and particle interactions before being removed by coolant.\n\nA coupled calculation must transfer equal and opposite quantities between subsystems. If an electrical model subtracts a loss that the thermal model does not receive, the combined simulation violates conservation even if each solver converges. Energy consistency is therefore both a physical requirement and a practical diagnostic for coupled numerical models."
    },
    {
      "heading": "Calculation methods, measurement, and reconciliation",
      "text": "A practical energy-balance study begins with a flowsheet, a boundary, a time basis, and a list of assumptions. Each material stream needs a flow rate and sufficient information to determine its thermodynamic state, usually temperature, pressure, composition, and phase. Heat, shaft power, electrical power, and accumulation terms must then be identified separately. A degrees-of-freedom analysis establishes whether the available equations and specifications are sufficient to determine the unknowns.\n\nMass conservation is normally resolved before, or simultaneously with, energy conservation. An apparently reasonable thermal calculation may still be impossible if inlet and outlet mass flows are inconsistent. Recycles create additional coupling because an outlet from one operation becomes an inlet elsewhere. Process simulators solve these linked equations using property models and numerical algorithms, but their results remain dependent on valid specifications and compatible reference states.\n\nMeasurements introduce practical limits. Temperature is measured by a sensor at a particular location, which may not represent a well-mixed bulk stream. Flow instruments may report mass flow, actual volumetric flow, or volumetric flow converted to specified reference conditions. Steam quality, entrained liquid, unmeasured condensate, and fluctuating flow can strongly affect calculated enthalpy rates. Calibration establishes instrument response but does not eliminate errors caused by poor installation or an unsuitable measurement location.\n\nDirect heat measurement through calorimetry often relies on a balance around a receiving material. For example, a coolant’s measured flow and enthalpy rise can estimate heat removed from equipment. Electrical input requires appropriate real-power measurement; voltage multiplied by current alone is not generally sufficient for alternating-current equipment with nonunity power factor or distorted waveforms. Shaft power can be obtained from torque and angular speed.\n\nA closure residual can be defined as\n\n\\[R= \\text{energy input} - \\text{energy output} - \\text{energy accumulation},\\]\n\nusing either rates or integrated quantities consistently. A nonzero residual may indicate an omitted transfer, inconsistent time averaging, instrument bias, or an inadequate property model. It does not demonstrate a failure of conservation. Relative closure errors must also state their normalization: dividing the same residual by total input, useful output, or a small net duty produces very different percentages.\n\nMeasurement uncertainty helps determine whether a residual is significant. Subtracting two large, nearly equal stream enthalpy rates can yield a small duty with a large relative uncertainty. This is common when estimating heat losses from small inlet–outlet temperature differences. Sensor biases and correlated errors may be more important than random scatter.\n\nData reconciliation adjusts measured quantities within their uncertainty structure while enforcing conservation constraints. It is distinct from arbitrarily forcing one stream to make the balance close. Appropriate reconciliation can improve estimates and expose gross measurement errors, but it cannot recover a missing physical mechanism merely by numerical adjustment. Transient tests additionally require synchronized measurements because a flow change and its downstream temperature response need not occur at the same instant."
    },
    {
      "heading": "Energy quality, efficiency, and wider applications",
      "text": "An energy balance constrains quantities but does not distinguish fully between their usefulness. One megajoule of electricity and one megajoule of low-temperature thermal energy are equal as energy quantities, yet they have different capacities to perform work. The second law of thermodynamics introduces entropy and restrictions on conversion, complementing rather than replacing the first-law balance.\n\nFor a steady control volume with heat transfers \\(\\dot Q_j\\) crossing boundary regions at thermodynamic temperatures \\(T_j\\), an entropy balance can be written as\n\n\\[0= \\sum_{\\mathrm{in}}\\dot m s - \\sum_{\\mathrm{out}}\\dot m s + \\sum_j\\frac{\\dot Q_j}{T_j} + \\dot S_{\\mathrm{gen}},\\]\n\nwhere \\(s\\) is specific entropy and \\(\\dot S_{\\mathrm{gen}}\\geq0\\) is entropy generation. Friction, mixing, chemical reactions away from equilibrium, and heat transfer across finite temperature differences can generate entropy while total energy remains conserved.\n\nExergy measures work potential relative to a specified environment. Its destruction is related to entropy generation by\n\n\\[\\dot X_{\\mathrm{dest}}=T_0\\dot S_{\\mathrm{gen}},\\]\n\nwhere \\(T_0\\) is the reference-environment temperature. An insulated throttling valve can conserve enthalpy closely while destroying appreciable exergy. Conversely, rejecting a large energy flow close to ambient temperature may represent less lost work potential than a smaller flow at very high temperature.\n\nEfficiency definitions therefore require an explicit purpose and boundary. A heat engine’s thermal efficiency is net work output divided by heat input. A refrigerator’s coefficient of performance is cooling duty divided by work input, so it may exceed one. Combined heat and power assigns useful status to both electricity and delivered heat, but comparisons depend on heat temperature and actual demand. Pinch analysis uses stream temperatures and duties to identify limits on process heat recovery; an overall energy surplus alone does not establish that suitable heat exchange is possible.\n\nThe same accounting principles appear in fields beyond process equipment. Building balances include solar gains, transmission through the envelope, ventilation, occupants, appliances, and thermal storage. In climate science, the planetary energy balance compares absorbed solar radiation with outgoing terrestrial radiation. A sustained imbalance changes the energy stored in the Earth system, with the ocean providing a major reservoir. Such a balance identifies net storage but requires atmospheric and oceanic transport models to explain its geographic distribution.\n\nIn biological systems, energy entering through food can leave as heat, external work, and chemical energy in excreted materials, or remain in changing body stores. Connections to metabolism require attention to chemical composition and the distinction between gross food energy and metabolically available energy. Conservation alone does not specify the physiological mechanisms governing those transfers.\n\nNational energy balances use a related accounting framework to record production, imports, transformation, final consumption, and losses. Their boundaries and statistical conventions differ from those of a thermodynamic equipment balance, particularly when assigning primary-energy equivalents to electricity from different sources. Comparisons between fuels, technologies, or countries consequently require compatible accounting conventions as well as a common unit of energy."
    }
  ],
  "links": [
    "energy",
    "mass-balance",
    "first-law-of-thermodynamics",
    "thermodynamics",
    "control-volume",
    "internal-energy",
    "heat",
    "international-system-of-units",
    "enthalpy",
    "temperature",
    "pressure",
    "equation-of-state",
    "heat-capacity",
    "latent-heat",
    "chemical-engineering",
    "steam-turbine",
    "heat-exchanger",
    "heat-pump",
    "district-heating",
    "hess-law",
    "haber-process",
    "fermentation",
    "fuel-cell",
    "battery",
    "energy-storage",
    "phase-change-material",
    "process-control",
    "pid-controller",
    "transport-phenomena",
    "finite-volume-method",
    "electric-motor",
    "solar-cell",
    "nuclear-reactor",
    "sensor",
    "calibration",
    "calorimetry",
    "power-factor",
    "measurement-uncertainty",
    "entropy",
    "combined-heat-and-power",
    "climate",
    "ocean",
    "metabolism"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}