  "id": "electrical-admittance",
  "title": "Electrical Admittance",
  "lang": "en",
  "source_lang": "en",
  "summary": "Electrical admittance is the reciprocal of impedance, expressing a circuit’s current response to an applied voltage through conductance and susceptance.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Admittance"
  ],
  "generated_at": "2026-11-05",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/electrical-admittance/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/electrical-admittance/",
      "json": "https://aiwiki.page/zh/electrical-admittance.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "Electrical admittance is a quantity describing the electric current produced by an applied voltage in a circuit or component. Denoted by \\(Y\\), it is the reciprocal of electrical impedance. In sinusoidal steady-state analysis, admittance is generally a complex quantity: its real part is conductance, and its imaginary part is susceptance. These parts describe, respectively, the current component in phase with the voltage and the current component a quarter-cycle out of phase. Admittance is measured in siemens, symbol \\(\\mathrm{S}\\)."
    },
    {
      "heading": "Definition and mathematical form",
      "text": "For a linear circuit driven at a single frequency, admittance is defined as\n\n\\[Y(\\omega)=\\frac{\\tilde I(\\omega)}{\\tilde V(\\omega)} =\\frac{1}{Z(\\omega)},\\]\n\nwhere \\(\\tilde I\\) and \\(\\tilde V\\) are current and voltage phasors, \\(Z\\) is impedance, and \\(\\omega=2\\pi f\\) is angular frequency. A phasor represents the amplitude and phase of a sinusoidal quantity without explicitly carrying its time dependence.\n\nAdmittance is written as the complex number\n\n\\[Y=G+jB,\\]\n\nwhere:\n\n- \\(G\\) is conductance, the real part of admittance;\n- \\(B\\) is susceptance, the imaginary part;\n- \\(j\\) is the imaginary unit, satisfying \\(j^2=-1\\).\n\nElectrical engineering commonly uses \\(j\\) rather than \\(i\\) for the imaginary unit to avoid confusion with current.\n\nThe magnitude and phase of admittance are\n\n\\[|Y|=\\sqrt{G^2+B^2}, \\qquad \\angle Y=\\operatorname{atan2}(B,G).\\]\n\nConsequently,\n\n\\[|\\tilde I|=|Y|\\,|\\tilde V|, \\qquad \\angle\\tilde I-\\angle\\tilde V=\\angle Y.\\]\n\nThus, admittance specifies both how much current flows for a given voltage and how that current is shifted in phase.\n\nFor a purely resistive element under direct current, admittance reduces to ordinary conductance:\n\n\\[Y=G=\\frac{1}{R},\\]\n\nwhere \\(R\\) is electrical resistance. This is the conductance form of Ohm’s law."
    },
    {
      "heading": "Units and terminology",
      "text": "The SI unit of admittance, conductance, and susceptance is the siemens:\n\n\\[1\\ \\mathrm{S}=1\\ \\Omega^{-1}=1\\ \\mathrm{A/V}.\\]\n\nThe older unit name mho, formed by reversing the word ohm, denotes the same quantity and was often represented by an inverted omega symbol. Siemens is the standard modern unit.\n\nAdmittance should not be confused with electrical conductivity. Admittance describes the terminal behavior of a particular component or network and depends on its geometry and connections. Conductivity is a material property. For a uniform conductor of length \\(\\ell\\), cross-sectional area \\(A\\), and conductivity \\(\\sigma\\), under conditions where a simple resistive model applies,\n\n\\[G=\\sigma\\frac{A}{\\ell}.\\]\n\nConductivity has units of siemens per metre, rather than siemens."
    },
    {
      "heading": "Relationship to resistance and reactance",
      "text": "If impedance is expressed as\n\n\\[Z=R+jX,\\]\n\nwhere \\(X\\) is reactance, taking its reciprocal gives\n\n\\[Y=\\frac{1}{R+jX} =\\frac{R-jX}{R^2+X^2}.\\]\n\nTherefore,\n\n\\[G=\\frac{R}{R^2+X^2}, \\qquad B=-\\frac{X}{R^2+X^2}.\\]\n\nConversely,\n\n\\[R=\\frac{G}{G^2+B^2}, \\qquad X=-\\frac{B}{G^2+B^2}.\\]\n\nThese relationships show that conductance is not generally the reciprocal of the real part of impedance. The equality \\(G=1/R\\) holds for a purely resistive impedance, not for an arbitrary complex impedance. Similarly, susceptance is not generally the reciprocal of reactance; for a purely reactive impedance, \\(B=-1/X\\).\n\nFor example, a component with\n\n\\[Z=3+j4\\ \\Omega\\]\n\nhas admittance\n\n\\[Y=\\frac{3-j4}{25} =0.12-j0.16\\ \\mathrm{S}.\\]\n\nIts admittance magnitude is \\(0.20\\ \\mathrm{S}\\), and its current lags the applied voltage by approximately \\(53.1^\\circ\\)."
    },
    {
      "heading": "Ideal circuit elements",
      "text": "The usual engineering convention represents sinusoidal signals using \\(e^{j\\omega t}\\). Under this convention, capacitive susceptance is positive and inductive susceptance is negative.\n\nResistor\n\nFor an ideal resistor,\n\n\\[Y_R=\\frac{1}{R}.\\]\n\nAdmittance is entirely real, and current and voltage are in phase.\n\nCapacitor\n\nFor an ideal capacitor with capacitance \\(C\\),\n\n\\[Z_C=\\frac{1}{j\\omega C}, \\qquad Y_C=j\\omega C.\\]\n\nIts susceptance is\n\n\\[B_C=\\omega C.\\]\n\nCurrent leads voltage by \\(90^\\circ\\), and admittance magnitude increases linearly with frequency. In the steady-state direct-current limit, an ideal capacitor behaves as an open circuit.\n\nInductor\n\nFor an ideal inductor with inductance \\(L\\),\n\n\\[Z_L=j\\omega L, \\qquad Y_L=-\\frac{j}{\\omega L}.\\]\n\nIts susceptance is\n\n\\[B_L=-\\frac{1}{\\omega L}.\\]\n\nCurrent lags voltage by \\(90^\\circ\\), and admittance magnitude decreases as frequency rises. In the ideal direct-current limit, the inductor behaves as a short circuit, although actual inductors have winding resistance and other losses.\n\nIf the alternative \\(e^{-j\\omega t}\\) convention is used, the signs of imaginary quantities reverse. Physical predictions are unchanged when the convention is applied consistently."
    },
    {
      "heading": "Parallel circuits and resonance",
      "text": "Admittance is particularly convenient for parallel circuits because all branches share the same voltage. Branch currents add, so\n\n\\[Y_{\\mathrm{total}}=\\sum_k Y_k.\\]\n\nConductances and susceptances can therefore be summed separately:\n\n\\[G_{\\mathrm{total}}=\\sum_k G_k, \\qquad B_{\\mathrm{total}}=\\sum_k B_k.\\]\n\nBy contrast, impedances add directly for series-connected elements.\n\nFor an ideal resistor, capacitor, and inductor connected in parallel,\n\n\\[Y=\\frac{1}{R} +j\\left(\\omega C-\\frac{1}{\\omega L}\\right).\\]\n\nThe capacitive and inductive susceptances cancel at\n\n\\[\\omega_0=\\frac{1}{\\sqrt{LC}}.\\]\n\nAt this parallel-resonance frequency, the input admittance is purely real. In this particular model, with a constant parallel resistance, admittance magnitude is minimized and impedance magnitude is maximized at resonance.\n\nFor a lossless parallel inductor–capacitor circuit, the ideal admittance is zero at resonance. Net terminal current is then zero for a finite applied sinusoidal voltage, even though nonzero currents flow through the individual branches. Real losses prevent the corresponding impedance from becoming infinite."
    },
    {
      "heading": "Admittance and electrical power",
      "text": "For sinusoidal alternating current, admittance provides a direct relationship between terminal voltage and power.\n\nUsing root-mean-square phasors and the passive sign convention, in which current enters the terminal labeled positive, complex power is\n\n\\[\\mathcal S=\\tilde V\\tilde I^{*} =|\\tilde V|^2Y^{*}.\\]\n\nThe asterisk denotes complex conjugation. Since \\(Y=G+jB\\),\n\n\\[\\mathcal S=P+jQ =V_{\\mathrm{rms}}^2G-jV_{\\mathrm{rms}}^2B.\\]\n\nHence,\n\n\\[P=V_{\\mathrm{rms}}^2G, \\qquad Q=-V_{\\mathrm{rms}}^2B.\\]\n\nHere \\(P\\) is average active power and \\(Q\\) is reactive power. Conductance determines average power absorbed at a specified voltage. Susceptance describes the out-of-phase response associated with periodic energy exchange rather than net energy consumption in ideal reactive elements.\n\nUnder this sign convention, an inductive load has \\(B<0\\) and \\(Q>0\\), while a capacitive load has \\(B>0\\) and \\(Q<0\\). A passive one-port cannot supply net average power in sinusoidal steady state; where its admittance is finite, its conductance is therefore nonnegative. Active circuits can exhibit negative conductance over some operating ranges by drawing energy from another source."
    },
    {
      "heading": "Network analysis and applications",
      "text": "Nodal analysis\n\nAdmittance is a natural variable in nodal analysis, which applies current balance at circuit nodes. For a branch between nodes \\(m\\) and \\(n\\),\n\n\\[I_{mn}=Y_{mn}(V_m-V_n).\\]\n\nA linear network can consequently be written in matrix form as\n\n\\[\\mathbf I=\\mathbf Y\\mathbf V,\\]\n\nwhere \\(\\mathbf Y\\) is the nodal admittance matrix. It combines branch admittances and network connectivity.\n\nAdmittance matrices are widely used in electrical-grid calculations. A bus admittance matrix represents transmission connections, transformers, and shunt elements. The network relation is linear for a specified model, but power-flow problems become nonlinear when bus injections are specified as powers rather than currents.\n\nFrequency-dependent measurements\n\nMeasuring admittance over frequency helps distinguish conductive, capacitive, and inductive behavior. Applications include component characterization, dielectric testing, and electrochemical measurements.\n\nFor an ideal parallel-plate sample with area \\(A\\), thickness \\(d\\), conductivity \\(\\sigma\\), and real permittivity \\(\\varepsilon\\), a simple model gives\n\n\\[Y=\\frac{A}{d}\\left(\\sigma+j\\omega\\varepsilon\\right).\\]\n\nMore complex materials may require frequency-dependent conductivity, complex permittivity, or additional elements representing interfaces and distributed processes.\n\nMultiport networks\n\nA network with several ports can be described by admittance parameters:\n\n\\[I_i=\\sum_j y_{ij}V_j.\\]\n\nWith currents defined as entering the ports, \\(y_{ij}\\) is the current response at port \\(i\\) per unit voltage at port \\(j\\), while all other port voltages are held at zero. These short-circuit admittance parameters are used in amplifier, filter, and network modeling."
    },
    {
      "heading": "Measurement and limitations",
      "text": "Admittance can be obtained by measuring voltage, current, and their phase difference with an impedance analyzer, an LCR meter, or a suitable bridge circuit. Practical measurements must account for lead resistance and inductance, stray capacitance, fixture effects, and instrument calibration. Near an open circuit, very small currents make leakage and parasitic capacitance especially important.\n\nA single frequency-dependent admittance most directly describes a linear, time-invariant circuit in steady state. For nonlinear devices, a small-signal admittance can be defined about a specified bias point, but it need not describe large-signal behavior. It may also depend on temperature, signal amplitude, and operating conditions.\n\nAt high frequencies, propagation delays and distributed effects can invalidate a lumped-element description. A terminal admittance can still be defined, but it may vary strongly with frequency and depend on the chosen reference plane. In multiport measurements, the input admittance also depends on how the other ports are terminated."
    }
  ],
  "links": [
    "electric-current",
    "electrical-impedance",
    "phasor",
    "complex-number",
    "electrical-conductance",
    "direct-current",
    "electrical-resistance",
    "ohms-law",
    "international-system-of-units",
    "electrical-conductivity",
    "capacitance",
    "inductance",
    "alternating-current",
    "matrix",
    "electrical-grid",
    "electrochemistry",
    "permittivity",
    "calibration",
    "temperature"
  ],
  "sources": [],