{
  "id": "cyclotron",
  "title": "Cyclotron",
  "lang": "en",
  "source_lang": "en",
  "summary": "A cyclotron accelerates charged particles along expanding orbits using a magnetic field and a radio-frequency electric field, supplying beams for research, isotope production, and medicine.",
  "category": "science",
  "subcategory": "physics",
  "type": "concept",
  "aliases": [
    "Cyclotron accelerator"
  ],
  "generated_at": "2026-11-03",
  "model": "pro/gpt-6.1-sol",
  "url": "https://aiwiki.page/en/cyclotron/",
  "translations": {
    "zh-Hans": {
      "url": "https://aiwiki.page/zh/cyclotron/",
      "json": "https://aiwiki.page/zh/cyclotron.json"
    }
  },
  "sections": [
    {
      "heading": "",
      "text": "A cyclotron is a type of particle accelerator in which charged particles repeatedly cross an accelerating electric field while a magnetic field bends their paths into approximately circular orbits. As the particles gain momentum, their orbital radius increases, allowing the same accelerating structure to be used many times. In its original form, the cyclotron exploits the nearly constant orbital frequency of a nonrelativistic particle in a uniform magnetic field.\n\nDeveloped into a working instrument by Ernest O. Lawrence and M. Stanley Livingston in 1931, the cyclotron made high-energy nuclear experiments possible without requiring an accelerating voltage equal to the full particle energy. Subsequent designs extended its energy range, improved beam focusing, and enabled intense, nearly continuous beams. Cyclotrons remain important sources of protons and heavier ions for nuclear physics, radioactive-isotope production, and selected forms of cancer treatment. Their design brings together orbital mechanics, radio-frequency engineering, magnetic-field shaping, vacuum technology, and the management of intense particle beams."
    },
    {
      "heading": "Historical development",
      "text": "The cyclotron emerged from efforts during the 1920s to accelerate charged particles to energies sufficient for controlled nuclear reactions. Electrostatic accelerators faced insulation and electrical-breakdown limits as their terminal voltages increased. An alternative was repeated acceleration: a particle could pass through several modest potential differences rather than a single enormous one. Rolf Widerøe demonstrated a radio-frequency linear accelerator in 1928, establishing an important practical precedent for this approach.\n\nLawrence, working at the University of California, Berkeley, recognized that a magnetic field could return particles repeatedly to an accelerating gap. In the nonrelativistic approximation, increasing speed would enlarge the orbit without changing its period. This made it possible to synchronize successive gap crossings with a fixed-frequency oscillator. Lawrence’s early collaborators included Niels Edlefsen and, subsequently, Livingston, whose experimental work produced a successful small cyclotron.\n\nIn 1931, an instrument with a chamber about 4.5 inches across accelerated hydrogen ions to approximately 80 kiloelectronvolts. Larger Berkeley machines followed rapidly. The 27-inch cyclotron reached energies of several megaelectronvolts, and the 60-inch cyclotron entered operation in 1939. Dimensions in these historical names generally refer to magnet pole diameter rather than the diameter of a particular particle orbit. Lawrence received the 1939 Nobel Prize in Physics for the invention and development of the cyclotron and its applications, especially in producing artificial radioactive elements.\n\nCyclotrons soon became tools for both physics and chemistry. In 1937, Carlo Perrier and Emilio Segrè identified technetium in molybdenum that had been irradiated in the Berkeley cyclotron. This work established the first element to be produced artificially before being identified in natural terrestrial material. Other accelerator-produced radionuclides opened new approaches to tracing chemical and biological processes.\n\nThe original constant-frequency design encountered limits as accelerated particles became relativistic. Two major developments addressed this difficulty. Vladimir Veksler in 1944 and Edwin McMillan independently in 1945 formulated phase-stability principles that supported frequency-modulated acceleration and the development of synchrocyclotrons and synchrotrons. Separately, Llewellyn H. Thomas proposed azimuthally varying magnetic fields in 1938, providing a route toward fixed-frequency acceleration with stronger focusing. Practical sector-focused machines expanded after the Second World War.\n\nCyclotron development consequently divided into several overlapping traditions: large research accelerators, compact isotope-production machines, and medical accelerators. Although higher-energy particle physics increasingly relied on other accelerator types, improvements in superconducting magnets, beam extraction, and target systems gave cyclotrons durable roles where dependable beams and high average current are especially valuable."
    },
    {
      "heading": "Orbital motion and resonant acceleration",
      "text": "The operating principle follows from the Lorentz force on a particle of electric charge \\(q\\), moving with velocity \\(\\mathbf{v}\\) through electric and magnetic fields:\n\n\\[\\frac{d\\mathbf{p}}{dt}=q\\left(\\mathbf{E}+\\mathbf{v}\\times\\mathbf{B}\\right).\\]\n\nThe magnetic force bends the trajectory but does no work on the particle, because it is perpendicular to the instantaneous velocity. The accelerating electric field supplies the increase in kinetic energy. For motion perpendicular to a uniform magnetic field, the orbit radius is\n\n\\[r=\\frac{p}{|q|B},\\]\n\nwhere \\(p\\) is the particle’s momentum. In the nonrelativistic limit, \\(p=mv\\), so the revolution angular frequency is\n\n\\[\\omega_c=\\frac{|q|B}{m}, \\qquad f_c=\\frac{|q|B}{2\\pi m}.\\]\n\nThe cancellation of speed is the essential feature: a faster particle follows a larger circle but takes the same time to complete a revolution.\n\nIn the classical two-electrode cyclotron, two hollow, approximately semicircular electrodes face one another across a narrow gap. Their shape gives them the name dees. An alternating voltage reverses polarity while a particle travels inside a dee, so the electric field accelerates it again when it reaches the gap from the opposite direction. At fundamental-frequency operation, the particle crosses the gap twice per revolution. Its trajectory is therefore a sequence of nearly semicircular arcs of increasing radius, rather than an exactly smooth mathematical spiral.\n\nIf a particle crosses an effective voltage \\(V_g\\), its energy gain is approximately \\(|q|V_g\\) when it arrives at the accelerating crest. More generally, the gain depends on radio-frequency phase and on the time spent crossing the gap. Modern cyclotrons may use several accelerating gaps and harmonic operation, with the radio-frequency frequency equal to an integer multiple of the orbital frequency. The usable phase relationships depend on the arrangement and angular extent of the electrodes.\n\nCombining the orbit equation with nonrelativistic kinetic energy gives\n\n\\[K=\\frac{q^2B^2r^2}{2m}.\\]\n\nA proton in a 1-tesla field has an orbital frequency of about 15.2 megahertz. At a radius of 0.5 metre, the same nonrelativistic estimate gives an energy of approximately 12 megaelectronvolts. Accelerator energies are commonly stated in electronvolts, whereas the accelerating voltage may be much smaller than the numerical energy expressed in electronvolts. The difference reflects repeated gap crossings: many individually modest energy increments accumulate over hundreds or thousands of turns."
    },
    {
      "heading": "Magnets, radio-frequency systems, and the vacuum chamber",
      "text": "A cyclotron is organized around a magnet whose pole faces surround an evacuated acceleration region. Conventional machines use copper coils and iron structures to establish and guide the magnetic flux. The iron yoke provides a return path and mechanical support, while carefully shaped pole surfaces determine the field experienced by the beam. Field quality matters across the whole acceleration region, not merely at its center, because particles encounter different radii as their energy increases.\n\nThe magnetic design must satisfy several competing requirements. Its average field determines the relationship between orbital radius and momentum; its radial variation affects synchronism; and its variation with angle provides focusing in many modern machines. Designers calculate these fields numerically, then measure the completed magnet. Small corrections can be made with shaped iron pieces, often called shims, and with correction coils. A field error that appears small locally can accumulate into a significant orbital displacement after many revolutions.\n\nMachines employing superconductivity can produce stronger fields with less electrical power dissipated in the main coils. Stronger fields reduce the radius required for a given particle momentum, permitting compact medical and research accelerators. This advantage comes with cryogenic equipment, thermal insulation, stored-energy protection, and substantial electromagnetic forces. Superconducting magnets do not remove the need for accurate field shaping, beam diagnostics, or adequate extraction clearance.\n\nThe radio-frequency system comprises an oscillator or frequency reference, power amplifiers, resonant cavities or dee structures, and controls that stabilize amplitude and phase. Resonance allows substantial accelerating voltages to be maintained efficiently, but conductive surfaces still dissipate heat and require cooling. Electrical breakdown, surface contamination, and multipactor discharges can limit usable voltage. The detailed cavity geometry depends on operating frequency, available space, number of gaps, and whether the accelerator operates at a fixed frequency or sweeps frequency during each acceleration cycle.\n\nA high vacuum reduces collisions between circulating particles and residual gas. Such collisions can scatter particles, change their charge state, or remove electrons from negative ions before the intended extraction point. Requirements depend strongly on particle species, energy, orbit length, and acceptable beam loss. Vacuum chambers, seals, internal sources, and targets must therefore be designed together; a component that releases gas can affect beam survival elsewhere in the machine.\n\nSupporting systems include cooling-water circuits, electrical supplies, control electronics, interlocks, and beam diagnostics. Position probes reveal orbit location, current monitors measure transported charge, and profile instruments characterize beam size. Many intercepting diagnostics cannot remain inserted into a full-power beam, so commissioning and routine operation often use different measurement modes. Reliable performance depends on coordinating these systems as an integrated accelerator rather than treating the magnet alone as the defining component."
    },
    {
      "heading": "Relativistic synchronism and beam focusing",
      "text": "The constant-frequency principle is exact only within the nonrelativistic approximation. Under special relativity, a particle’s momentum is \\(p=\\gamma mv\\), where \\(m\\) is its invariant mass and\n\n\\[\\gamma=\\frac{1}{\\sqrt{1-v^2/c^2}}.\\]\n\nIts revolution frequency in a uniform magnetic field becomes\n\n\\[f_{\\mathrm{rev}}=\\frac{|q|B}{2\\pi\\gamma m}.\\]\n\nAs energy increases, \\(\\gamma\\) increases and the orbital frequency decreases. A particle that initially arrives at the accelerating gap at the correct phase gradually falls out of step with a fixed-frequency voltage. This is a loss of synchronism, not a failure of the magnetic field to bend its trajectory.\n\nThe effect is significant well before a proton approaches the speed of light extremely closely. At a kinetic energy of 20 megaelectronvolts, its \\(\\gamma\\) is approximately 1.021, corresponding to about a 2 percent reduction in orbital frequency at fixed field. Because acceleration requires many turns, even this relatively small difference can produce a large accumulated phase error. Electrons become relativistic at much lower kinetic energies because their rest energy is only about 0.511 megaelectronvolt; conventional cyclotrons are consequently much better suited to heavier charged particles.\n\nSynchronism is only one requirement. A real beam has finite width and includes particles with small deviations from the ideal orbit. The magnetic and electric fields must keep these deviations bounded. Radial oscillations describe departures within the median plane, while vertical oscillations describe motion above and below it. Their frequencies relative to the revolution frequency, often called tunes, determine the beam’s response to field imperfections and resonances.\n\nIn an approximately axisymmetric, weak-focusing magnet, a field that decreases gently with radius provides vertical focusing. Defining the field index as\n\n\\[n=-\\frac{r}{B}\\frac{dB}{dr},\\]\n\nthe idealized nonrelativistic tune relations are\n\n\\[\\nu_r^2=1-n, \\qquad \\nu_z^2=n.\\]\n\nBoth motions are stable in this approximation when \\(0<n<1\\). However, maintaining fixed-frequency relativistic acceleration requires the average field to rise outward, approximately in proportion to \\(\\gamma\\). An axisymmetric field with that behavior does not supply the needed vertical focusing.\n\nAzimuthally varying fields resolve this conflict. Alternating stronger-field hills and weaker-field valleys create a focusing contribution through field gradients and sector boundaries. Spiral-shaped sectors can strengthen this effect. The resulting strong focusing allows an outward-rising average field to coexist with stable vertical motion. Practical design still requires avoiding or deliberately crossing resonances, accounting for imperfections, and controlling collective electric forces within high-current bunches."
    },
    {
      "heading": "Principal cyclotron designs",
      "text": "The classical cyclotron uses an approximately uniform magnetic field and a fixed radio frequency. It is conceptually simple and historically important, but its useful energy range is restricted by relativistic phase slip and by the practical requirements of focusing and extraction. Classical machines demonstrated repeated resonant acceleration and supplied many early nuclear-physics experiments. Most contemporary high-performance cyclotrons modify at least one of their basic assumptions.\n\nA synchrocyclotron compensates for relativistic slowing of the orbital frequency by sweeping the accelerating frequency downward during each acceleration cycle. Particles are captured and accelerated as bunches during part of that sweep. A new cycle begins after the accelerated bunch is extracted or lost. This produces an intrinsically pulsed beam and generally a lower average current than comparable continuous-wave cyclotron arrangements, although actual performance depends on the design. Frequency modulation permits high proton energies in a comparatively compact magnet, a property used in some modern medical systems.\n\nAn isochronous cyclotron instead keeps the radio frequency fixed while shaping the average magnetic field to increase with radius. The field compensates for the increasing relativistic factor so that the revolution frequency remains approximately constant. Azimuthally varying sector fields provide the necessary focusing. Such machines can accept successive bunches continuously at the radio-frequency rate and therefore support high average currents. Their engineering challenge is to maintain both adequate isochronism and stable beam motion throughout the acceleration region.\n\nA separated-sector cyclotron divides the bending system into distinct sector magnets, leaving substantial spaces between them for accelerating cavities, injection, extraction, and diagnostics. These machines are particularly useful at higher energies and high beam power, where large accelerating voltages and accessible beam paths become important. The Paul Scherrer Institute’s Ring cyclotron, which accelerates protons to 590 megaelectronvolts, is a prominent example. Its role in a multistage accelerator complex also illustrates that a cyclotron need not contain the particle source or begin acceleration near zero energy.\n\nSuperconducting construction is a separate classification rather than a competing acceleration principle. An isochronous cyclotron or a synchrocyclotron may employ a superconducting magnet. Likewise, positive-ion versus negative-ion acceleration describes the beam species and extraction strategy, not whether the accelerator is isochronous.\n\nDesign choice depends on the intended task. A facility producing short-lived medical isotopes may prioritize moderate energy, high current, dependable operation, and rapid target changes. A nuclear-structure laboratory may require multiple ion species and variable energies. A therapy installation emphasizes beam delivery and clinical integration. These requirements explain why no single cyclotron configuration has replaced all the others: magnetic compactness, beam current, energy flexibility, extraction efficiency, and operational complexity must be balanced differently in each application."
    },
    {
      "heading": "Particle sources, injection, extraction, and beam transport",
      "text": "Cyclotrons accelerate ions, not neutral atoms. Their sources create charged particles by processes such as electron-impact ionization in a gas discharge. Common beams include protons, deuterons, helium ions, and heavier ions in selected charge states. Negative hydrogen ions, consisting of a proton with two electrons, are particularly important in compact isotope-production machines. Species selection affects orbital frequency, magnetic rigidity, source design, achievable energy, and extraction method.\n\nAn internal source introduces particles near the magnetic center, avoiding a separate low-energy transport line. Its disadvantages include limited access, gas loading inside the cyclotron, and constraints on source geometry. External sources allow more elaborate preparation and maintenance but require injection optics. Axial injection sends the beam approximately along the magnetic-field direction; an electrostatic device such as a spiral inflector bends it into the median plane. Matching the incoming beam to the cyclotron’s accepted positions, angles, energies, and phases is essential for efficient capture.\n\nExtraction is difficult because adjacent high-energy turns may lie very close together. A thin electrostatic septum can be placed between the final circulating turn and the extracted trajectory. The electric field then deflects the beam into a channel leading out of the magnet. Particles striking the septum cause heating and activation, so sufficient turn separation is crucial. Larger energy gain per turn, controlled orbit precession, and carefully adjusted fields can improve extraction clearance.\n\nFor negative hydrogen ions, charge-exchange extraction offers an alternative. A thin stripping foil removes the two electrons, converting the ion into a proton. Because the charge changes sign, the magnetic force bends the outgoing proton in the opposite sense from the circulating negative ion. This can extract the beam without inserting a conventional electrostatic septum between closely spaced final turns. Foil position and geometry can also provide operational flexibility, including extraction toward different beamlines.\n\nStripping extraction introduces its own constraints. Foils heat, suffer radiation damage, and eventually require replacement. Negative hydrogen ions can also lose electrons through collisions with residual gas or through field-induced detachment in sufficiently strong magnetic fields. These mechanisms constrain the combination of beam energy, magnetic field, vacuum quality, and acceptable losses; the compactness available from a stronger magnet is therefore not unlimited.\n\nAfter extraction, magnets steer and focus the beam through transport lines to targets or experiments. Collimators remove unwanted trajectories, while momentum-selecting systems can improve energy definition at the cost of transmission. Beam emittance, which describes the spread of particle positions and angles in phase space, is as important as current. A high-current beam is useful only if its spatial distribution and energy characteristics are compatible with the receiving apparatus."
    },
    {
      "heading": "Nuclear research and high-power secondary beams",
      "text": "Cyclotrons became central instruments of experimental nuclear physics because they provided controlled beams with known particle species and adjustable experimental conditions. Bombarding a target with protons, deuterons, or helium ions can induce reactions that reveal nuclear energy levels, angular-momentum assignments, reaction thresholds, and interaction mechanisms. Measurements of outgoing particles and radiation connect observed spectra to the internal structure of the atomic nucleus.\n\nReaction experiments depend on more than the nominal beam energy. Target thickness influences energy loss and resolution; beam polarization can reveal spin-dependent interactions; and detector placement determines which angular distributions can be measured. Cyclotron beams support elastic and inelastic scattering, transfer reactions, and charge-exchange reactions. In a transfer reaction, for example, one or more nucleons move between projectile and target, providing information about nuclear configurations that may be difficult to isolate through electromagnetic measurements alone.\n\nCyclotrons also produce secondary beams. When an energetic primary beam strikes a suitable target, the resulting particles or unstable nuclei can be collected for further experiments. Protons incident on thick targets generate neutrons through nuclear reactions; at sufficiently high energies, spallation produces many neutrons as an excited nucleus ejects constituents. These sources support studies of materials, nuclear reaction data, and other applications requiring intense neutron fluxes.\n\nHigh-energy proton beams can also produce pions, whose decays provide muons. Muon beams are used both in particle-physics experiments and as probes of magnetic and electronic properties in matter. The Swiss high-intensity proton accelerator complex at the Paul Scherrer Institute supplies secondary-particle facilities from its 590-megaelectronvolt beam. At TRIUMF in Canada, a large negative-hydrogen-ion cyclotron delivers protons at energies up to approximately 500 megaelectronvolts for several research programs, including radioactive-ion-beam production.\n\nThe engineering scale of these applications is set by beam power as well as particle energy. For particles of charge magnitude \\(e\\),\n\n\\[P=\\frac{I}{e}K,\\]\n\nwhere \\(I\\) is average electrical beam current and \\(K\\) is energy per particle in joules. A 1-milliampere proton beam at 100 megaelectronvolts carries 100 kilowatts. If stopped in a target, most of that power ultimately becomes heat. Target cooling, thermal stress, radiation damage, and remote handling therefore become central elements of the experiment.\n\nAt high current, small fractional losses can also have major consequences. Lost particles activate accelerator structures and may limit maintenance access. Collective forces within the beam, commonly described as space-charge effects, can enlarge its distribution and make clean extraction harder. The research utility of a high-power cyclotron thus depends on controlling losses throughout injection, acceleration, extraction, and target delivery, rather than merely maximizing the current measured at the source."
    },
    {
      "heading": "Radioisotope production and nuclear medicine",
      "text": "A major contemporary use of cyclotrons is the production of radioactive isotopes for imaging, research, and selected therapeutic applications. An accelerated particle strikes a target nucleus and induces a reaction that produces the desired radionuclide. Production rates depend on beam energy, reaction cross section, target composition and thickness, beam current, and irradiation time. Competing reactions can create unwanted radionuclides, so higher energy does not automatically give a better medical product.\n\nA widely used example is fluorine-18 production through proton bombardment of oxygen-18-enriched water:\n\n\\[{}^{18}\\mathrm{O}(p,n){}^{18}\\mathrm{F}.\\]\n\nFluorine-18 has a half-life of approximately 110 minutes and emits positrons. After chemical incorporation into a suitable tracer, it supports positron emission tomography (PET). Fluorodeoxyglucose labeled with fluorine-18 is a prominent example. The accelerator produces the radionuclide; subsequent radiochemical processing produces the administered radiopharmaceutical.\n\nOther important PET radionuclides include carbon-11, nitrogen-13, and oxygen-15, with half-lives of approximately 20 minutes, 10 minutes, and 2 minutes, respectively. Their short lifetimes strongly influence facility organization. Oxygen-15 generally requires production close to the point of use, whereas fluorine-18 can support regional distribution when transport and processing times permit. Some isotopes used in PET can also be supplied by radionuclide generators, so PET imaging does not invariably require an on-site cyclotron.\n\nFor an idealized target with a constant production rate \\(R\\), negligible depletion, and no significant competing destruction of the product, the activity at the end of irradiation is\n\n\\[A(t)=R\\left(1-e^{-\\lambda t}\\right), \\qquad \\lambda=\\frac{\\ln 2}{t_{1/2}}.\\]\n\nThis saturation relationship shows why extending irradiation eventually gives diminishing returns: radioactive decay increasingly offsets new production. Following irradiation, activity decreases during chemical processing, quality testing, transport, and preparation.\n\nTargets are highly engineered components. Liquid targets require pressure containment and efficient heat transfer; gas targets require suitable windows and control of gas composition; solid targets require cooling and subsequent chemical separation. Isotopically enriched materials can be costly, making recovery and recycling important. Production also requires shielded handling equipment, radionuclide identification, chemical-purity testing, and validated manufacturing procedures.\n\nCyclotrons can produce longer-lived radionuclides such as iodine-123, copper-64, and zirconium-89, although the relevant particle energies, target materials, and chemical methods differ. Accelerator-based production of technetium-99m through proton irradiation of enriched molybdenum-100 is another established route under appropriate operating conditions. In each case, useful output is determined by radionuclidic purity and chemical suitability as well as activity: a large yield containing problematic impurities may be less valuable than a smaller, cleaner production batch."
    },
    {
      "heading": "Particle therapy, radiation protection, and operating constraints",
      "text": "Cyclotrons are used in proton therapy, where accelerated protons deposit energy in tissue through interactions dominated by ionization and excitation. Their depth–dose distribution includes the Bragg peak, a concentration of energy deposition near the end of their range. Clinical delivery systems use beam energies and modulation methods selected to cover a specified treatment volume. Protons of approximately 230–250 megaelectronvolts can reach depths of roughly 30–40 centimetres in water, with the exact range depending on energy and the material traversed.\n\nMany therapy cyclotrons deliver a nominally fixed extraction energy. An energy degrader reduces that energy for shallower treatment depths, and an energy-selection system removes particles outside the required momentum range. Degradation also increases angular spread and reduces transmitted current, producing secondary radiation and activation in surrounding equipment. The complete installation therefore includes substantial beam-conditioning and shielding systems beyond the accelerator itself.\n\nBeam delivery may use passive scattering components or magnetically scanned narrow beams. In pencil-beam scanning, steering magnets move the beam across a transverse plane, while changes in energy select different depths. Delivery accuracy depends on calibrated beam position, energy, intensity, and timing. The clinical suitability of a system consequently depends on the integrated accelerator, transport line, monitoring equipment, treatment planning, and quality-assurance procedures rather than on cyclotron specifications alone.\n\nRadiation protection addresses both prompt radiation during operation and residual radioactivity after shutdown. Beam interactions with targets, collimators, degraders, and accelerator structures can generate neutrons and gamma rays. Shielding design depends on particle energy, current, target materials, operating schedule, and building geometry. Access interlocks prevent entry into hazardous areas during irradiation, while radiation surveys and controlled maintenance procedures address activated components afterward.\n\nOperational limits often arise from coupled effects. Increasing current raises target heating and can worsen space-charge-driven beam spreading. Increasing magnetic field reduces machine size but can complicate negative-ion acceleration and extraction. Raising accelerating voltage improves turn separation but increases demands on radio-frequency power, cooling, and electrical reliability. Higher extraction efficiency reduces activation, yet achieving it may require tighter control of the beam distribution and magnetic field.\n\nCyclotrons also occupy a particular position among accelerator technologies. A synchrotron varies its bending field and accelerating conditions so that particles remain near a fixed orbit, making it more suitable for many much higher-energy applications. A linear accelerator avoids recirculating orbits but requires successive accelerating structures along the beam path. Cyclotrons are especially effective where repeated use of the same accelerating structures, compact construction, and substantial average current outweigh the restrictions imposed by orbital geometry and extraction."
    }
  ],
  "links": [
    "particle-accelerator",
    "nuclear-physics",
    "nobel-prize-in-physics",
    "lorentz-force",
    "electric-charge",
    "electric-field",
    "magnetic-field",
    "momentum",
    "kinetic-energy",
    "electronvolt",
    "superconductivity",
    "special-relativity",
    "speed-of-light",
    "ionization",
    "proton",
    "phase-space",
    "atomic-nucleus",
    "scattering",
    "muon",
    "isotope",
    "water",
    "half-life",
    "positron-emission-tomography",
    "radioactivity",
    "neutron",
    "gamma-ray",
    "synchrotron"
  ],
  "sources": [],
  "license": "https://creativecommons.org/licenses/by/4.0/"
}